Jinhu Boyuan Automation Instrument Co., Ltd
Home>Products>Current output type liquid turbine flowmeter
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    13179500501
  • Address
    Shenhua Avenue, Jinhu County Industrial Park, Jiangsu Province
Contact Now
Current output type liquid turbine flowmeter
Overview of LWGY series current output liquid turbine flowmeter: The LWGY series current output liquid turbine flowmeter has been optimized and design
Product details

Current output type liquid turbine flowmeter

1、 Overview: The LWGY series current output liquid turbine flowmeter is a new generation of turbine flowmeter that has been optimized and designed based on domestic and foreign flow instrument technology. It has the characteristics of simple structure, lightweight, high accuracy, good reproducibility, sensitive response, and easy installation, maintenance, and use. It is widely used to measure liquids in closed pipelines that do not corrode stainless steel 1Cr18Ni9Ti, 2Cr13, corundum Al2O3, and hard alloys, and have no impurities such as fibers or particles. The flow meter can be used after real liquid calibration for liquids with a dynamic viscosity greater than 5 × 10-6m2/s at working temperature. If paired with display instruments with special functions, it can also perform quantitative control, over limit alarm, etc., making it an ideal instrument for flow measurement and energy conservation. This type of turbine flow product itself does not have on-site display function, and only transmits the flow signal in the form of 4-20mA for remote output. The instrument is inexpensive, highly integrated, and compact in size, making it particularly suitable for use with computer control systems such as secondary displays, PLCs, and DCS. 2、 Product features: 1. Height, generally up to ± 1% R, ± 0.5% R, high-precision type up to ± 0.2% R; 2. Good repeatability, short-term repeatability up to 0.05%~0.2%, precisely because of its good repeatability, such as frequent calibration or online calibration can achieve extremely high accuracy, it is a preferred flowmeter in trade settlement; 3. Wide range, with a medium to large caliber of up to 1:20 and a small caliber of 1:10; 4. Compact and lightweight structure, easy installation and maintenance, and high circulation capacity; 5. Suitable for high voltage measurement, there is no need to open holes on the instrument body, making it easy to make high voltage instruments; 6. There are various types of specialized sensors that can be designed according to the specific needs of users, such as low-temperature, bidirectional, downhole, sand mixing, etc; 7. Can be made into an insertion type, suitable for measuring large diameters, with low pressure loss, low price, can be removed without interruption, and easy installation and maintenance.

3、 Basic parameters and technical performance

1.Technical performance: Table 1

Instrument caliber and connection method

4Threaded connections are used for 6, 10, 15, 20, 25, 32, and 40

(15, 20, 25, 32, 40) 50, 65, 80, 100, 125, 150, 200 are connected by flanges

accuracy class

± 1% R, ± 0.5% R

Range ratio

1:10;1:15; 1:20

Instrument material

304Stainless steel, 316 (L) stainless steel, etc

Temperature of the tested medium (℃)

-20~+120℃

environmental condition

Temperature -10~+55 ℃, relative humidity 5%~90%, atmospheric pressure 86~106Kpa

output signal

4-20mADCcurrent signal

power supply

+24VDC

Signal transmission line

20.3 (two-wire system)

Distance

≤1000m

Signal line interface

Hausman connector

Explosion proof grade

Non explosion proof products

protection grade

IP65

2.Measurement range and working pressure: Table 2

Instrument diameter (mm)

Normal flow range (m3/h)

Expand flow range (m3/h)

Conventional withstand pressure (MPa)

Specially designed pressure resistance level (MPa) (flange connection method)

DN 4

0.04~0.25

0.04~0.4

6.3

12、 16. 25

DN 6

0.1~0.6

0.06~0.6

6.3

12、 16. 25

DN 10

0.2~1.2

0.15~1.5

6.3

12、 16. 25

DN 15

0.6~6

0.4~8

6.32.5 (flange)

4.0、 6.3, 12, 16, 25

DN 20

0.8~8

0.45~9

6.32.5 (flange)

4.0、 6.3, 12, 16, 25

DN 25

1~10

0.5~10

6.32.5 (flange)

4.0、 6.3, 12, 16, 25

DN 32

1.5~15

0.8~15

6.32.5 (flange)

4.0、 6.3, 12, 16, 25

DN 40

2~20

1~20

6.32.5 (flange)

4.0、 6.3, 12, 16, 25

DN 50

4~40

2~40

2.5

4.0、 6.3, 12, 16, 25

DN 65

7~70

4~70

2.5

4.0、 6.3, 12, 16, 25

DN 80

10~100

5~100

2.5

4.0、 6.3, 12, 16, 25

DN 100

20~200

10~200

2.5

4.0、 6.3, 12, 16, 25

DN 125

25~250

13~250

1.6

2.5、 4.0, 6.3, 12, 16

DN 150

30~300

15~300

1.6

2.5、 4.0, 6.3, 12, 16

DN 200

80~800

40~800

1.6

2.5、 4.0, 6.3, 12, 16

4、 Instrument selection:Table 3

model

explain

LWGY

/

/

/

/

/

/

state-owned

call

open up or clear out by poking or jabbing

footpath

4







4mmThe standard range is 0.04-0.25m3/h, and the wide range is 0.04-0.4m3/h

6

6mmThe standard range is 0.1-0.6m3/h, and the width measuring wheel is 0.06-0.6m3/h

10

10mmThe standard range is 0.2-1.2m3/h, and the wide range is 0.15-1.5m3/h

15

15mmThe standard range is 0.6~6m3/h and the wide range is 0.4~8m3/h

20

20mmThe standard range is 0.8-8m3/h, and the wide range is 0.4-8m3/h

25

25mmThe standard range is 1-10m3/h, and the wide range is 0.5-10m3/h

32

32mmThe standard range is 1.5-15m3/h, and the wide range is 0.8-15m3/h

40

40mmThe standard range is 2-20m3/h, and the wide range is 1-20m3/h

50

50mmThe standard range is 4-40m3/h, and the wide range is 2-40m3/h

65

65mmThe standard range is 7-70m3/h, and the wide range is 4-70m3/h

80

80mmThe standard range is 10-100m3/h, and the wide range is 5-100m3/h

100

100mmThe standard range is 20-200m3/h, and the wide range is 10-200m3/h

125

125mmThe standard range is 25-250m3/h, and the wide range is 13-250m3/h

150

150mmThe standard range is 30-300m3/h, and the wide range is 15-300m3/h

200

200mmThe standard range is 80-800m3/h, and the wide range is 40-800m3/h

Type

A

4-20mATwo wire current output

accuracy class

05

Accuracy level 0.5

10

Accuracy level 1.0

Turbine

Type

W

Wide range turbine

S

Standard turbine

texture of material

S

304stainless steel

L

316(L) Stainless steel

Explosion proof

N

Basic type, non explosion proof product

pressure rating

N

Conventional (refer to Table 2)

H(x)

High voltage (refer to Table 2)

Note: DN15 to DN40 are usually threaded connections. If you wish to use flange connections, please add "(FL)" after "nominal diameter"
For example, choosing a flange connection typeNon explosion proof turbine flowmeterTo measure water, a 4-20mA signal output is required. The pipeline is DN40 and requires an accuracy level of 0.5. The instrument is made of 304 stainless steel and has a pressure resistance of 16MPa. The measurement range is the standard range, and the product model should be LWGY-40 (FL) A/05/S/S/N/H16


Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!