Cross linked power cable
Product standard: This product is produced in accordance with GB1270 "Copper core and Aluminum core Plastic Insulated Power Cables with Rated Voltage
Product details

Product standard: This product is produced in accordance with GB1270 "Copper core and Aluminum core Plastic Insulated Power Cables with Rated Voltage of 35kV and Below" standard, and can also be produced according to the recommended standards of the International Electrotechnical Commission IEC, British standards, German standards, and American standards according to user needs.

Cable model:
YJV YJLV YJY YJLY
YJV22 YJLV22 YJV23 YJLV23
YJV23 YJLV23 YJV33 YJLV32
YJLV33
Scope of application:
This product is suitable for distribution of electrical energy on power frequency rated voltage 3.6/kV-26/35kV distribution lines.
Usage features:
The rated voltage Uo/U of the power frequency is 3.6/6KV-26/35KV.
The maximum allowable long-term working temperature for cable conductors is 90 ℃.
During a short circuit (with a maximum duration of 5 seconds), the maximum temperature of the cable conductor shall not exceed 250 ℃.
The ambient temperature during cable laying should not be lower than 0 ℃.
● Cable bending radius: Three core cables shall not be less than 15 times the outer diameter of the cable; Single core cables shall not be less than 20 times the outer diameter of the cable.

Selection of cable rated voltage

The rated voltage of the cable should be suitable for the operating conditions of the cable system, expressed in Uo/U (Um) KV.
Uo - rated power frequency voltage between conductors used in cable design and ground or metal shielding;
Rated power frequency voltage between conductors used in U-cable design;
Um - the maximum value of the "highest system voltage" that the equipment can withstand.

The recommended Uo values for cables used in three-phase systems are shown in the following table:

U
kv
Um
kv
Uo*kv
Class A and B systems
Class C system
6
7.2
3.6
6
10
12
6
8.7
15
17.5
8.7
12
20
24
12
18
30
36
18
-
35
40.5
21
26

A-class system - When any phase conductor of this system comes into contact with the ground or grounding conductor, it can be separated from the system within 1 minute;
B-class system - This type of system only includes conditions for short-term operation of single-phase grounding faults. The grounding fault time should not exceed 1 hour, but in any case, it should not exceed 8 hours. The total duration of grounding faults per year should not exceed 125 hours;
C-class system - a system that does not belong to Class A or Class B.

Production scope:

model
Type

core count
Number
of
cores
Rated Voltage kV
3.6/6
6/6
6/10
8.7/10
8.7/15
12/20
18/20
18/30
21/35
26/35
Nominal cross-section of conductor
mm2
YJV
YJLV
YJY
YJLY
1
25-800
25-800
25-800
35-800
50-630
50-630
50-630
3
25-630
25-630
25-500
35-500
50-400
50-400
50-400
YJV22
YJLV22
YJV23
YJLV23
1
25-800
25-800
25-800
35-800
50-630
50-630
50-630
3
25-630
25-630
25-500
35-500
50-400
50-400
50-400
YJV32
YJLV32
YJV33
YJLV33
1
25-800
25-800
25-800
35-800
50-630
50-630
50-630
3
25-630
25-630
25-400
35-400
50-240
50-185
50-150