CNIK-610 motor protector
System Overview
Product details


System Overview


CNIKThe 610 series motor protector is a comprehensive low-voltage motor protection device. Capable of various voltage and current protection functions, switch input, and two-way communication in engineering applicationsRS485 communication and analog output functions provide the most economical, effective, and reasonable means for industrial production process control and power distribution automation. Establish a safe, reliable, simple, fast, and powerful system for motor protection, measurement control, management, and communication that meets fieldbus requirements for users. The product complies with the electromagnetic compatibility standards IEC61000-4, 2-3-4-5-6-8-11, Level 4.


characterization


Three phase current measurement function

Zero sequence or leakage current measurement function

Three phase voltage measurement function

Complete motor voltage and current protection

Auxiliary power supplyAC85V-450V,/DC100V-550V supports power supply for zero wire motor applications

Support on-site/Remote communication control for start stop, forward and reverse start, Y/∆ start, and other multiple starts

LCD display, on-site setting of protection control parameters

Easy and flexible installation/Maintenance

Can be compared with mainstreamPLC, DCS networking

Can be accessedMODBUS field industrial bus, realizing network communication

Design license according to relay protection standards

Three proof treatment for circuit boards, supporting use in harsh environments

FEATURES


Real time measurement function:Ua、Ub、Uc、Ia、Ib、Ic、IO、P、Q、S、COSF、Freq、Ep、Eq

Switch input:10 channel switch input

LED indication: 6-way LED lights indicate motor operation, faults, and communication

AO transmission: 2-channel 4-20mA output, load ≤ 500ohm

Communication:2 RS485 channels, supporting standard Modbus RTU

relay protection

function

Protect Content

content

Quick break protection

Time limited quick break during startup process

6-12Ie, can set mouth action

Quick disconnect after startup

3-12Ie, instantaneous exit action

overload protection

Action coefficient

1.15Ie

Non action coefficient

1.05Ie

Heat dissipation method

Uniform heat dissipation

Heat dissipation time

0-655.36s

Blockage protection

After startup is completed

Motor current protection I>Idz, t>Tdz outlet

Overvoltage protection

After startup is completed

Setting (105-150 ℅ Ue) U>Ugy, t<Tgy Export

Imbalance protection

After startup is completed

Setting (5 ℅ -300 ℅)

I0 grounding protection

Ordinary zero sequence transformer

Startup process and delayed segmentation after startup

Leakage current transformer 0.1A

Startup process and delayed segmentation after startup

non-electricity protection

Non electric quantity 1 protection

External fault switch connected to DI0-DI7

Non electric quantity 2 protection

External fault switch connected to DI0-DI7

Contactor segmented energy

Prevent contactor contacts from burning out

Ifd sets the allowable segmented current for the contactor

undercurrent protection

Execute after startup

0.1-1 Ie

under voltage protection

Execute after startup

75%-95%Ue

Over frequency protection

Overfrequency protection

Set frequency 50-65Hz

Underfrequency protection

Underfrequency protection

Set frequency 45-50Hz

Long startup time, voltage loss, restart

During the startup process

Anti vibration function

SOE event records: 50 SOE event records

Motor start stop mode vacancy rate: supports on-site operation/Remote control of motor start stop


TECHNICAL INDEX


project

parameter

measure

measure

Voltage measurement range

5% -150% Ue, accuracy: 0.5%

Current measuring range

5% -1200% Ie, accuracy: 0.5%

active power

0-99999.9KW, Precision: 1%

reactive power

0-99999.9KVar, Precision: 1%

apparent power

0-99999.9KVA, Precision: 1%

frequency

45Hz-65Hz, Precision: ± 0.02Hz

Active energy

0-9KW, Precision: 2%

Reactive energy

0-9KVar, Precision: 2%

defend

protect

Voltage protection range

0-1.2Ue

Current protection range

0-12Ie

Action value accuracy

3%

time accuracy

Fixed time limit (<3% or 80ms), inverse time limit (<5%)

become different

deliver

range

4-20mA

load

≤500ohm

accuracy

0.5%

DI output

Photoelectric isolation

Isolation voltage 500Vac rms

power supply

External passive dry contact (internal power supply)

DO output

output form

Mechanical contacts, closing and alarm (normally open), tripping (normally closed)

Maximum contact resistance of the contact point

30mΩ/1A

Maximum allowable voltage

250Vac/dc

Maximum allowable current (resistive)

5A/250Vac

bad

area

operation temperature

-10-60℃

storage temperature

-20-70℃

Working humidity

5% -95% RH without condensation

Panel protection level

IP54

Working power supply

85-400VAC, 100V-560VDC

power consumption

10W