Biolot1000Large scale preparationProtein Purification SystemThe maximum flux can reach 60L/H, which can be used for rapid purification of target products such as proteins, peptides, and nucleic acids.The hardware of Biolot system consists ofPEEK chromatography pump、Sample pump、UV detector、Conductivity/PH detector、Automatic fraction collection valve、Mixer and valveComposed and used in conjunction with bioview software, chromatography columns, and packing materials, the instrument can meet any purification challenge. The system configuration is flexible, supports various chromatography techniques, and meets the development requirements of customers for purification processes from small-scale to pilot scale.
Biolot1000 protein purification system product performance:
Can quickly separate biomolecules such as proteins and peptides
Highly flexible modular configuration makes the research process more intuitive
Adopting high-precision plunger pump, high stability, and low pulse
High sensitivity online detection, optional UV PH、 Various detectors such as conductivity and differential refractive index
The flow path is made of PEEK material, which has good biocompatibility
The pump head has an automatic cleaning function to avoid buffer residue and crystal precipitation
Fully automatic fraction collector with multiple collection modes and configurable collection tubes of various specifications
Standard gradient program, customers can reset according to experimental needs
Storage and execution of chromatographic separation methods
Highly intelligent operating system, easy and convenient to use
The control software meets the certification requirements of FDA 21 CFR Part 11
Technical parameters of Biolot1000 protein purification system:
model |
Biolot 1000 |
System pump |
PEEK high-pressure chromatography pump (high precision, gradient design, biocompatibility) |
Flow velocity range |
0.1-1000ml/min |
Flow velocity accuracy |
± 0.5% |
Pressure range |
0—10Mpa |
pressure fluctuation |
≤0.2MPa |
Gradient type |
Steps, linearly varying gradients, and gradients that can be modified online |
Minimum gradient adjustment |
± 0.5% ABS (dual pump) |
Detector light source |
Imported deuterium lamp+tungsten lamp (system automatically switches lamp sources) |
Detection wavelength |
190-800nm (simultaneous detection of two wavelengths) |
Wavelength accuracy |
±1nm |
Range of absorbance |
-3-3 AU (linear 0-2 AU) |
Conductivity range |
0—500 ms/cm |
PH range |
0—14 |
fraction collection |
Fully automatic fraction collection valve |
Power Supply |
85 ~ 264VAC,50Hz |
control software |
A software workstation based on Windows system, with multi module system control and design that complies with FDA 21 CFR Part 11 certification. Its functions include multi-user management, instrument control, method preparation, data processing, and report printing |
Reference size |
Infusion pump: 550 × 420 × 222mm3UV detector: 370 × 240 × 152mm3Conductivity/PH: 370 × 240 × 100mm3 |