Model of biogas flame arresterGZW-Z

Product IntroductionbiogasblockfiredeviceIt is to prevent external flames from entering equipment or pipelines containing flammable and explosive gases, or to prevent flames from spreading between equipment and pipelines. Flame arresters are used to prevent the spread of flames

When passing through the narrow pores of a thermal conductor,The principle of extinguishing due to heat loss is designed and manufactured. The biogas flame arrester is suitable for installation on pipelines and storage tanks that transport combustible biogas gas, to prevent

Stop the reverse propagation of flames in the pipeline under abnormal conditions to avoidThe occurrence of catastrophic accidents. The fire-resistant plate is made of stainless steel material, which is corrosion-resistant and easy to clean. The shell is made of stainless steel

Steel, carbon steel, aluminum alloy, and cast steel are various materials that can meet the needs of different process pipelines. The biogas flame arrester produced by our company has a compact structure, high reliability, and flame retardant core

The product has advantages such as explosion-proof, anti-corrosion, strong fire resistance, and easy cleaning. Suitable for the storage and torch of flammable gas pipelines, such as gasoline, kerosene, light diesel, benzene, toluene, crude oil and other oil products

system,It can also be used as pipeline supplies for acetylene, oxygen, nitrogen, and natural gas.

阻火器工作原理The flame retardant core of the biogas flame arrester is made of stainless steel“N”The double-layer corrugated tape is a fire-resistant core component with a cross shaped bracket inside the core component (or on the table)

Press on the surfaceYThe frame is used to enhance the reliability of the core components and prevent the explosive pressure generated by the medium that ignites the core components from dissipating. Design the height of the triangular hole based on this principle to prevent the passage of flames

By adding sufficient channel length to absorb the heat of the flame, it can be extinguished in the core, avoiding the possibility of gas reigniting at the other end of the core.

Material and parameters of biogas flame arrester

Shell material: carbon steel, aluminum alloy, stainless steel:SUS304TheSUS304LTheSUS316TheSUS316 L

Flame retardant core material: stainless steel corrugated plate

Sealing ring material: oil resistant asbestos rubber, polytetrafluoroethylene

Applicable media: gases such as hydrogen, oxygen, liquefied gas, etc

Working temperature ≤400

Work pressure:1.0-4.0Mpa

Explosion proof level:BS5501IIATheIIBTheIIC.

Flame arrester performance

1Qualified explosion resistance performance,continuous13The secondary explosion resistance performance test can block fire every time.

2Qualified fire resistance performance, fire resistance test1There is no tempering phenomenon within hours.

3The shell water pressure test is qualified. This product has a reasonable structure, light weight, and corrosion resistance. Easy to maintain and install.

Size of biogas flame arrester

Specifications

size

pressure

PN

External connection dimensionsmm

bolt

K

D

DL

L

quantity

thread

DN20

1.6

MPa

75

105

195

200

4

M12

DN25

85

115

195

200

4

M12

DN40

110

150

245

240

4

M16

DN50

125

165

245

240

4

M16

DN80

160

200

280

250

8

M16

DN100

180

220

335

260

8

M16

DN150

240

285

460

360

8

M20

DN200

295

340

520

420

12

M20

DN250

355

405

580

430

12

M24

DN300

410

460

705

450

12

M24

Standard for biogas flame arresters: Flange standard:GBTheHGTheSHTheHGJTheJBTheANSLTheJISWaiting for standards. (User specified, please indicate pressure level) Execution standard:GB13347-92

Fire resistance performance and test methods of flame arresters for petroleum gas pipelinesSH/T3413-99Selection, Inspection, and Acceptance of Fire Arresters for Petrochemical Petroleum Gas PipelineHG/T20570.19-95

The setting of flame arresters. Production, inspection, and acceptance standards for flame arresters:SY/T0512-1996Fire arresters for oil storage tanks, testing basis:GB5908-86Oil Storage Tank Flame Arrester

Performance and Experimental Methods.

Application of biogas flame arrester

1On pipelines transporting flammable gases.

2Torch system.

3Oil and gas recovery system.
4
The pipe network for heating furnace fuel gas.

5Gas purification and chemical system.

6Gas analysis system.

7Coal mine gas emission system.

Installation and maintenance of biogas flame arresters:

1 In order to ensure the performance of the flame arrester meets its intended use, it is necessary to carefully read the instructions provided by the manufacturer before installing the flame arrester, and carefully check whether the label is consistent with the requirements of the installed pipeline.

2 The flow direction mark on the flame arrester must be consistent with the flow direction of the medium.

3 It should be checked every six months. Check whether the fire-resistant layer has defects such as blockage, deformation, or corrosion.

4 The blocked fire-resistant layer should be cleaned thoroughly to ensure that each hole is unobstructed, and any deformed or corroded fire-resistant layer should be replaced.

5When cleaning the flame arrester core components, high-pressure steam, non corrosive solvents, or compressed air should be used for blowing, and sharp hardware brushes should not be used.

6 When reinstalling the flame retardant layer, the gasket should be updated and the sealing surface should be confirmed to be clean and undamaged, without any air leakage

Shanghai Nanshi is a professionalManufacturer of flame arrestersThe products produced by the company include breathing valves, flame arresters, fire-resistant breathable caps, fire-resistant vacuum pressure caps, aluminum alloy ball valves, and aluminum alloy single flanges

Ball valve, oil discharge port, double door bottom valve, oil measuring hole and other supporting accessories.

Dear user: Welcome to our websitehttp://www.shhxfcj.com,If you have any suggestions or questions about our products or services, please contact us immediately! We one

We will do our best to provide you with high-quality service! Telephone:.

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!