English

Shanghai Baotuo Instrument Co., Ltd
Home>Products>BSF-80 infinite inverted fluorescence microscope
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    13774333655
  • Address
    No. 1786 Nanlu Road, Nicheng Town, Pudong New Area, Shanghai
Contact Now
BSF-80 infinite inverted fluorescence microscope
BSF-80 infinite inverted fluorescence microscope
Product details
  • Instrument usage:

    BSF-80The inverted fluorescence microscope (infinite beam path) consists of an epifluorescence microscopy system and an inverted biological microscopy system. It adopts an excellent infinite optical system and is equipped with a long working distance flat field objective lens and a large field eyepiece. The compact and stable high rigidity body fully embodies the anti vibration requirements of microscopic operations. The rotating swing in swing out spotlight system can be used to observe uncontaminated cultured cells in high culture dishes or cylindrical flasks. The falling fluorescence microscopy system adopts a modular design concept, which can safely and quickly adjust the illumination system and switch the fluorescence filter components. The product can be used for microscopic observation of cellular tissues and transparent liquid tissues, as well as for fluorescence microscopy observation in fields such as biopharmaceuticals, medical testing, and disease prevention.

    Body system:



    Standard configuration:

    Technical Specifications

    eyepiece

    Broad VisionWF10X(Number of fields of view Φ22mm)The telescope in the center

    Infinite flat field achromatic objective lens

    objective lens

    PLL 10X0.25Working distance:4.3 mmCover glass thickness:1.2mm.

    PLL 20X0.40Working distance:8.0 mmCover glass thickness:1.2mm.

    PLL 40X0.60Working distance:3.5 mmCover glass thickness:1.2mm.

    Phase contrast objective lens

    PLL 10X0.25 PHP2Working distance:4.3 mmCover glass thickness:1.2mm.

    PLL 20X0.40 PHP2Working distance:8.0 mmCover glass thickness:1.2mm.

    PLL 40X0.60 PHP2Working distance:3.5 mmCover glass thickness:1.2mm.

    Eyepiece tube

    tilt45˚,Pupil distance adjustment range53~75mm.

    Falling fluorescent lighting system

    power distribution box110V/230Voptional

    mercury lamp100W/DC

    Fluorescent filter group

    group

    type

    Excitation plate wavelength

    Transmitting film wavelength

    ultraviolet+Purple(UV+V

    ultraviolet(UV)

    320nm~380nm

    435nm

    purple(V)

    380nm~415nm

    475nm

    blue+Green(B+G

    blue(B)

    450nm~490nm

    515nm

    green(G)

    495nm~555nm

    595nm

    focusing system

    Coarse micro coaxial,Equipped with locking and limiting devices,Micro grid value:2Mm.

    converter

    Five hole converter

    stage

    Fixed stage size:227mmX208mm.

    Glass circular loading platform size: Ø118mm.

    Mechanical movement size, movement range: longitudinal77mmHorizontally114mm

    Culture dish tray one

    Inner groove size:86mm(Width)X129.5mm(Long), can be adapted to circular culture dishes with a diameter of Ø87.5mm

    Cultivation dish tray 2

    Inner groove size:34mm(Width)X77.5mm(Long), can be adapted to circular culture dishes with a diameter of Ø68.5mm

    Petri dish tray three

    Inner groove size:57mm(Width)X82mm(Long)57mm (W)X82mm (L)

    Transmissive lighting system

    Rotary phase contrast spotlight, working distance55mm

    6V30WHalogen lamp, adjustable brightness

    Frosted glass, blue and green color filters

    Imaging system:

    This series of cameras adoptsSonySonyExmor,Exmor R, Exmor RSBack illuminated styleCMOSSensors,EXmorseriesCMOSThe sensor adopts double-layer noise reduction technology, which has ultra-high sensitivity and ultra-low noise.

    thisThe camera is integrated12Ultra fine hardware image signal processor and video streaming engine for bit processing((Ultra-fineTMHISPVP),Through thisHISPVPImplement hardwareDemosaic,Adjustment, automatic exposure, gain adjustment, one click white balance, image color adjustment, saturation adjustment, gamma correction, brightness adjustment, contrast adjustment,BayerFormat image conversionRAWData for final use8/12bitOutput.HISPVPTransforming traditional computers that should have beenCPUThe processing has been transferred to hardware processing, greatly improving the camera's transmission speed and reducingCPUThe occupancy rate.

    利用USB3.0Data transmission technology enables fast and stable video transmission.

    thisThe camera randomly provides advanced video and image processing application softwareImageView;provideWindows/ Linux/OSXmulti-platformSDK;Support nativeC/C++, C#/VB.Net, Directshow, Twain API.

    thisbeThe above characteristics of column cameras can be used fordark fieldorOrdinary Mingchangorlow lightorFluorescence fieldThe shooting of microscopic images.

    thisseriesThe basic characteristics of a camera are as follows:

    l adoptSony Exmor CMOSBack illuminated sensorsCinterfaceCMOS USB3.0camera;

    l Adopting parallel arrangementA / DConversion technology achieves ultra-low noise and low power consumption;

    l Hardware resolution spans across3.1M~20MWaiting for various;

    l Zinc aluminum alloy precisionCNCshell

    l USB3.0Interface ensures high transmission rate;

    l Ultra-FineTMhardwareIPSThe video streaming engine ensures accurate color reproduction and provides advanced video and image processing application software quickly with the camera;

    provideWindows/Linux/OSXmulti-platformSDK,Support nativeC/C++, C#/VB.Net, Directshow, Twain API;

    System parameters:

    Product Model

    630ten thousandUSB3.0High sensitivity microscope camera system

    sensor

    SONY 6.3M/IMX178(C)

    chip size

    1/1.8“ (7.37x4.92)

    image processor

    Ultra-FineTMhardwareIPSVideo streaming engine

    Pixel size(um

    2.4x2.4

    frame rate@resolution

    38@1536x 1024

    30@3072 x2048

    exposure time

    0.1ms~15s

    exposure control

    manual/automatic

    white balance

    ROIwhite balance/manualTemp-Tintadjust

    color temperature control

    manual/automatic

    Settings

    White balance, exposure time, noise reduction, gain, gamma, etc

    Operating temperature

    -10~ 50

    Operating humidity

    30~80%RH

    operating system

    Microsoft® Windows®XP/ Vista / 7 / 8 /10(32 & 64bit)

    Optical interface

    standardCinterface

    data interface

    USB3.0

    capture/controlAPI

    Native C/C++, C#/VB.NET, Directshow, TwainandLabview

    Recording method

    Images and videos

    Cooling method*

    natural cooling

    power supply

    USBPlug in power supply (shared data interface)

  • Instrument usage:

    BSF-80The inverted fluorescence microscope (infinite beam path) consists of an epifluorescence microscopy system and an inverted biological microscopy system. It adopts an excellent infinite optical system and is equipped with a long working distance flat field objective lens and a large field eyepiece. The compact and stable high rigidity body fully embodies the anti vibration requirements of microscopic operations. The rotating swing in swing out spotlight system can be used to observe uncontaminated cultured cells in high culture dishes or cylindrical flasks. The falling fluorescence microscopy system adopts a modular design concept, which can safely and quickly adjust the illumination system and switch the fluorescence filter components. The product can be used for microscopic observation of cellular tissues and transparent liquid tissues, as well as for fluorescence microscopy observation in fields such as biopharmaceuticals, medical testing, and disease prevention.

    Body system:



    Standard configuration:

    Technical Specifications

    eyepiece

    Broad VisionWF10X(Number of fields of view Φ22mm)The telescope in the center

    Infinite flat field achromatic objective lens

    objective lens

    PLL 10X0.25Working distance:4.3 mmCover glass thickness:1.2mm.

    PLL 20X0.40Working distance:8.0 mmCover glass thickness:1.2mm.

    PLL 40X0.60Working distance:3.5 mmCover glass thickness:1.2mm.

    Phase contrast objective lens

    PLL 10X0.25 PHP2Working distance:4.3 mmCover glass thickness:1.2mm.

    PLL 20X0.40 PHP2Working distance:8.0 mmCover glass thickness:1.2mm.

    PLL 40X0.60 PHP2Working distance:3.5 mmCover glass thickness:1.2mm.

    Eyepiece tube

    tilt45˚,Pupil distance adjustment range53~75mm.

    Falling fluorescent lighting system

    power distribution box110V/230Voptional

    mercury lamp100W/DC

    Fluorescent filter group

    group

    type

    Excitation plate wavelength

    Transmitting film wavelength

    ultraviolet+Purple(UV+V

    ultraviolet(UV)

    320nm~380nm

    435nm

    purple(V)

    380nm~415nm

    475nm

    blue+Green(B+G

    blue(B)

    450nm~490nm

    515nm

    green(G)

    495nm~555nm

    595nm

    focusing system

    Coarse micro coaxial,Equipped with locking and limiting devices,Micro grid value:2Mm.

    converter

    Five hole converter

    stage

    Fixed stage size:227mmX208mm.

    Glass circular loading platform size: Ø118mm.

    Mechanical movement size, movement range: longitudinal77mmHorizontally114mm

    Culture dish tray one

    Inner groove size:86mm(Width)X129.5mm(Long), can be adapted to circular culture dishes with a diameter of Ø87.5mm

    Cultivation dish tray 2

    Inner groove size:34mm(Width)X77.5mm(Long), can be adapted to circular culture dishes with a diameter of Ø68.5mm

    Petri dish tray three

    Inner groove size:57mm(Width)X82mm(Long)57mm (W)X82mm (L)

    Transmissive lighting system

    Rotary phase contrast spotlight, working distance55mm

    6V30WHalogen lamp, adjustable brightness

    Frosted glass, blue and green color filters

    Imaging system:

    This series of cameras adoptsSonySonyExmor,Exmor R, Exmor RSBack illuminated styleCMOSSensors,EXmorseriesCMOSThe sensor adopts double-layer noise reduction technology, which has ultra-high sensitivity and ultra-low noise.

    thisThe camera is integrated12Ultra fine hardware image signal processor and video streaming engine for bit processing((Ultra-fineTMHISPVP),Through thisHISPVPImplement hardwareDemosaic,Adjustment, automatic exposure, gain adjustment, one click white balance, image color adjustment, saturation adjustment, gamma correction, brightness adjustment, contrast adjustment,BayerFormat image conversionRAWData for final use8/12bitOutput.HISPVPTransforming traditional computers that should have beenCPUThe processing has been transferred to hardware processing, greatly improving the camera's transmission speed and reducingCPUThe occupancy rate.

    利用USB3.0Data transmission technology enables fast and stable video transmission.

    thisThe camera randomly provides advanced video and image processing application softwareImageView;provideWindows/ Linux/OSXmulti-platformSDK;Support nativeC/C++, C#/VB.Net, Directshow, Twain API.

    thisbeThe above characteristics of column cameras can be used fordark fieldorOrdinary Mingchangorlow lightorFluorescence fieldThe shooting of microscopic images.

    thisseriesThe basic characteristics of a camera are as follows:

    l adoptSony Exmor CMOSBack illuminated sensorsCinterfaceCMOS USB3.0camera;

    l Adopting parallel arrangementA / DConversion technology achieves ultra-low noise and low power consumption;

    l Hardware resolution spans across3.1M~20MWaiting for various;

    l Zinc aluminum alloy precisionCNCshell

    l USB3.0Interface ensures high transmission rate;

    l Ultra-FineTMhardwareIPSThe video streaming engine ensures accurate color reproduction and provides advanced video and image processing application software quickly with the camera;

    provideWindows/Linux/OSXmulti-platformSDK,Support nativeC/C++, C#/VB.Net, Directshow, Twain API;

    System parameters:

    Product Model

    630ten thousandUSB3.0High sensitivity microscope camera system

    sensor

    SONY 6.3M/IMX178(C)

    chip size

    1/1.8“ (7.37x4.92)

    image processor

    Ultra-FineTMhardwareIPSVideo streaming engine

    Pixel size(um

    2.4x2.4

    frame rate@resolution

    38@1536x 1024

    30@3072 x2048

    exposure time

    0.1ms~15s

    exposure control

    manual/automatic

    white balance

    ROIwhite balance/manualTemp-Tintadjust

    color temperature control

    manual/automatic

    Settings

    White balance, exposure time, noise reduction, gain, gamma, etc

    Operating temperature

    -10~ 50

    Operating humidity

    30~80%RH

    operating system

    Microsoft® Windows®XP/ Vista / 7 / 8 /10(32 & 64bit)

    Optical interface

    standardCinterface

    data interface

    USB3.0

    capture/controlAPI

    Native C/C++, C#/VB.NET, Directshow, TwainandLabview

    Recording method

    Images and videos

    Cooling method*

    natural cooling

    power supply

    USBPlug in power supply (shared data interface)

  • Online inquiry
    • Contacts
    • Company
    • Telephone
    • Email
    • WeChat
    • Verification Code
    • Message Content

    Successful operation!

    Successful operation!

    Successful operation!