Ammonia concentration detector
Product description: Ammonia concentration detector, model: PN-2000-NH3-L, three wire 4-20mA current signal/RS-485 digital signal/(national standard M
Product details
• Gas detection: Ammonia (NH3)
• Detection principle: Electrochemical principle
Installation methods: wall mounted, pipe mounted (thread size: M40X1.5mm), flow-through, pump suction optional
• Measurement range: 0-10 ppm、20ppm、50ppm、100ppm、200ppm、500ppm、1000ppm、2000ppm、5000ppm 、7000 ppm、 Optional
Resolution: 0.001ppm (0-1ppm); 0.01ppm(0~100ppm); 0.1ppm (0-1000ppm or above)
Accuracy: ≤± 3% (actual concentration, higher accuracy depends on the specific sensor)
• Repeatability: ≤± 1%
• Zero drift: ≤± 1% (F.S/year)
Response time: ≤ 30 seconds (T90)
• Recovery time: ≤ 40 seconds
Output signal: Users can choose according to their actual requirements, with a maximum transmission distance of 2000 meters (single core 1mm ² shielded cable)
1. Three wire 4-20mA current signal output (two-wire system can be specially customized)
2. RS-485 digital signal output, national standard Modbus signal output (optional)
3. Dual relay signal output, one set of active DC24V output and one set of passive signal output
4. Alarm signal output: on-site sound and light alarm, alarm sound:<90 decibels (optional)
• Connection method: 3/4 "NPT internal thread
Shell material: die cast aluminum, explosion-proof, corrosion-resistant, and oxidation resistant
Explosion proof mark: ExdII CT6, Explosion proof certificate number: CNEx12.2576
• Protection level: IP65
• Working power supply: 24VDC (12-24VDC)
• Working temperature: -20~50 ℃ (customized according to special requirements)
• Working humidity: ≤ 95% RH, no condensation (humidity>90% RH, can be equipped with a filter)
Work pressure: ≤ 200Kpa
• Size: 183 × 143 × 107mm
• Weight: 1.5Kg
• Detection principle: Electrochemical principle
Installation methods: wall mounted, pipe mounted (thread size: M40X1.5mm), flow-through, pump suction optional
• Measurement range: 0-10 ppm、20ppm、50ppm、100ppm、200ppm、500ppm、1000ppm、2000ppm、5000ppm 、7000 ppm、 Optional
Resolution: 0.001ppm (0-1ppm); 0.01ppm(0~100ppm); 0.1ppm (0-1000ppm or above)
Accuracy: ≤± 3% (actual concentration, higher accuracy depends on the specific sensor)
• Repeatability: ≤± 1%
• Zero drift: ≤± 1% (F.S/year)
Response time: ≤ 30 seconds (T90)
• Recovery time: ≤ 40 seconds
Output signal: Users can choose according to their actual requirements, with a maximum transmission distance of 2000 meters (single core 1mm ² shielded cable)
1. Three wire 4-20mA current signal output (two-wire system can be specially customized)
2. RS-485 digital signal output, national standard Modbus signal output (optional)
3. Dual relay signal output, one set of active DC24V output and one set of passive signal output
4. Alarm signal output: on-site sound and light alarm, alarm sound:<90 decibels (optional)
• Connection method: 3/4 "NPT internal thread
Shell material: die cast aluminum, explosion-proof, corrosion-resistant, and oxidation resistant
Explosion proof mark: ExdII CT6, Explosion proof certificate number: CNEx12.2576
• Protection level: IP65
• Working power supply: 24VDC (12-24VDC)
• Working temperature: -20~50 ℃ (customized according to special requirements)
• Working humidity: ≤ 95% RH, no condensation (humidity>90% RH, can be equipped with a filter)
Work pressure: ≤ 200Kpa
• Size: 183 × 143 × 107mm
• Weight: 1.5Kg
Online inquiry