HC175M~HC480M single and double temperature series
Product Features
Multiple temperature control precision options to meet different needs, with optional temperature control precision of ± 0.1 ℃, ± 1.0 ℃, ± 2.5 ℃
Dual temperature and dual circulation system, each temperature can be controlled separately (the temperature setting of the secondary circuit needs to be higher than that of the main circuit)
Efficient plate heat exchanger, national patented anti freezing technology for plate heat exchangers
Efficient integrated "V" - shaped sealed condenser
Pressure indication for waterway system and refrigeration system
Efficient and low-noise external rotor fan, integrated air cooling and heat dissipation (optional water cooling method), upper air outlet method
Equipped with liquid level alarm, flow alarm, temperature alarm, phase sequence alarm, pressure alarm, and component fault alarm
Equipped with chiller alarm signal output
With the function of recording the running time and start stop times of the main components
Equipped with external control start and stop functions
Equipped with heating function to achieve rapid temperature rise in low-temperature environments (optional)
High resolution LCD display screen
Using stainless steel water pumps, PP and PE water tanks, the overcurrent components and pipelines will not rust at all
Main circulation with coarse filtration function, secondary circulation with fine filtration function (optional)
Function Introduction
The HC175M/HC250M/HC350M/HC480M series chillers have single temperature multi cycle and dual temperature multi cycle systems. Circulating water at higher temperatures can effectively prevent condensation. There are two commonly used temperature control accuracies (± 0.1 ℃/± 1.0 ℃) to choose from, meeting different needs. The practical cooling capacity of the unit ranges from 17.5KW to 48KW, which can meet the cooling requirements for long-term stable operation of heating equipment with a heat generation of ≤ 48KW.
Application scope
High power cutting laser/high-power welding laser/fiber laser/centralized cooling supporting host/exposure machine/vacuum coating production line/electroplating production line/injection molding machine, etc
HC175M~HC480M single and double temperature series
Product Features
Multiple temperature control precision options to meet different needs, with optional temperature control precision of ± 0.1 ℃, ± 1.0 ℃, ± 2.5 ℃
Dual temperature and dual circulation system, each temperature can be controlled separately (the temperature setting of the secondary circuit needs to be higher than that of the main circuit)
Efficient plate heat exchanger, national patented anti freezing technology for plate heat exchangers
Efficient integrated "V" - shaped sealed condenser
Pressure indication for waterway system and refrigeration system
Efficient and low-noise external rotor fan, integrated air cooling and heat dissipation (optional water cooling method), upper air outlet method
Equipped with liquid level alarm, flow alarm, temperature alarm, phase sequence alarm, pressure alarm, and component fault alarm
Equipped with chiller alarm signal output
With the function of recording the running time and start stop times of the main components
Equipped with external control start and stop functions
Equipped with heating function to achieve rapid temperature rise in low-temperature environments (optional)
High resolution LCD display screen
Using stainless steel water pumps, PP and PE water tanks, the overcurrent components and pipelines will not rust at all
Main circulation with coarse filtration function, secondary circulation with fine filtration function (optional)
Function Introduction
The HC175M/HC250M/HC350M/HC480M series chillers have single temperature multi cycle and dual temperature multi cycle systems. Circulating water at higher temperatures can effectively prevent condensation. There are two commonly used temperature control accuracies (± 0.1 ℃/± 1.0 ℃) to choose from, meeting different needs. The practical cooling capacity of the unit ranges from 17.5KW to 48KW, which can meet the cooling requirements for long-term stable operation of heating equipment with a heat generation of ≤ 48KW.
Application scope
High power cutting laser/high-power welding laser/fiber laser/centralized cooling supporting host/exposure machine/vacuum coating production line/electroplating production line/injection molding machine, etc
Function Introduction:
The HC175M/HC250M/HC350M/HC480M series chillers have single temperature multi cycle and dual temperature multi cycle systems. Circulating water at higher temperatures can effectively prevent condensation. There are two commonly used temperature control accuracies (± 0.1 ℃/± 1.0 ℃) to choose from, meeting different needs. The practical cooling capacity of the unit ranges from 17.5KW to 48KW, which can meet the cooling requirements for long-term stable operation of heating equipment with a heat generation of ≤ 48KW.
Application scope:
High power cutting laser/high-power welding laser/fiber laser/centralized cooling supporting host/exposure machine/vacuum coating production line/electroplating production line/injection molding machine, etc