Acid alkali liquid flowmeter, intelligent electromagnetic flowmeter, Xi'an saltwater flowmeter
Main technical parameters
1. Execution standard: JB/T 9248-1999
2. Nominal diameter: 15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1200, 1400, 1600, 1800, 2000, 2200, 2400, 2600, 2800, 3000
3. Maximum flow rate: 15m/s
4. Accuracy:
DNl5~DN600, Indication: ± 0.3% (flow rate ≥ 1m/s); ± 3mm/s (flow rate<1m/s)
DN700—DN3000, ± 0.5% of the indicated value (flow rate ≥ 0.8m/S); ± 4mm/s (flow rate<0.8m/S)
5. Fluid conductivity: ≥ 5uS/cm
6. Nominal pressure:
DNl5~DN150(4.0MPa)
DNl5~DN600(1.6MPa)
DN200~DN1000(1.0MPa)
DN700~DN3000(0.6MPa)
Special order (6.3, 10MPa)
7. Environmental temperature:
Sensor (-25 ℃ -+60 ℃)
Converter and integrated type (-10 ℃ -+60 ℃)
8. Lining materials: polytetrafluoroethylene, chloroprene rubber, polyurethane, perfluoroalkoxy (F46), mesh PFA
9. Maximum fluid temperature:
- Body type (70 ℃)
Separate type: lined with chloroprene rubber (80 ℃); 120℃)
Separate type: polyurethane lining (80 ℃)
Separate type: PTFE lining (100 ℃; 150℃)
Separate type: Perfluoroethylene propylene (F46) (100 ℃); 150℃)
Separate type: PFA mesh (100 ℃); 150℃)
10. Signal electrode and ground electrode materials: stainless steel 0Crl8Nil2M02Ti, Hastelloy C, Hastelloy B, titanium, tantalum, platinum/iridium alloy, stainless steel coated with tungsten carbide
11. Electrode scraper mechanism: DN300-DN3000
12. Connecting flange material: carbon steel
13. Grounding flange material: Stainless steel 1Cr18Ni9Ti
14. Imported protective flange material:
DN65-DNL50 (stainless steel 1Cr18Ni9Ti)
DN200~DNl600 (carbon steel and stainless steel 1Cr18Ni9Ti)
15. Shell protection:
DNl5~DN3000 separable rubber or polyurethane lined sensor (IP65 or IP68)
Other sensors, body type flow meters, and separate converters (IP65)
16. Spacing (separated type): The distance between the converter and the sensor is generally not more than 100m
Installation precautions for acid-base liquid flow meters
1. The sulfuric acid flowmeter should be installed at the lower and vertically upward positions of the horizontal pipeline, avoiding installation at the highest and vertically downward points of the pipeline.
2. It should be installed at the rising point of the pipeline. When installing in the open discharge pipeline, it should be installed at the lower part of the pipeline.
4. If the pipeline drop exceeds 5m, install an exhaust valve downstream of the sensor.
5. The sensor * * * cannot be installed at the inlet and outlet of the pump, but should be installed at the outlet of the pump.
6. There should be at least a 10 * D (D is the inner diameter of the flowmeter) straight pipe section in front of the flowmeter, and a 5 * D straight pipe section behind it.
Acid alkali liquid flowmeter, intelligent electromagnetic flowmeter, Xi'an saltwater flowmeter