Acela universal desktop fume hood
Esco Frontier Acela is a laboratory universal desktop fume hood. The precisely tuned aerodynamic performance ensures user safety, aesthetic and ergono
Product details
  • singleSpecial operation window, with quick gas capture on both sides, upper edge, lower edge, and operation area guide plate.
  • Cone shaped fiberglass exhaust hoodReduce turbulence of airflow, static pressure loss, noise level, and increase uniformity of surface wind speed.
  • Perfect Pitch Profile ™ Improve visibility inside the fume hood.
  • The three wall structure and sprocket glass door system provide maximum durability.
  • Limit glass doors to exceed457mm (18")The movement. When the current window glass exceeds this height, it will automatically slowly fall back to a safe height(Esco anti slip mechanism for front window frame).
  • Window locks can keep the front window glass in the fully open position for easy handling of equipment, or in the fully closed position to restrict access to the fume hood.
  • The concept of constant volume and high performance eliminates the need for complex variable air volume systems.
  • The Frontier Acela fume hood provides excellent isolation (less than 0.05ppm) and reduces surface airflow velocity to 60 fpm when the glass door is fully open and 18 "restricted. It is tested indoors and in accordance with ASHRAE-110 and EN14175-3 approved testing procedures.
  • warpGermanTintschl Engineering AGIndependent testing and certificationCompliant with EuropeEN 14175-3Industry standards.
  • All Frontier Acela fume hoods include a water and gas enhancer installed on the top of the cabinet ™ Remote control device, including two socket interfaces (socket code must be specified when ordering).
Model Naming Guide
EFA-_D_ _W-_
outer width take the place of

a sign or object indicating number

Internal depth take the place of

a sign or object indicating number

Internal surface layer take the place of

a sign or object indicating number

Front glass window frame type take the place of

a sign or object indicating number

colour

take the place of

a sign or object indicating number

supply voltage take the place of

a sign or object indicating number

1220 mm (48.0") 4U 900 mm (35.4") D Esco Resinate ™ R vertical V Esco White W 220-240 VAC, 50/60 Hz 8
1525 mm (60.0") 5U Esco Resinate Plus ™ U Integrated vertical and horizontal C 110-120 VAC, 50/60 Hz 9
1830 mm (72.0") 6U
2440 mm (96.0") 8U
Overall, Frontier ® Acela ™ Fume hood
model 220-240 VAC,
50/60 Hz, 1ø
EFA-4UDRVW8 EFA-5UDRVW8 EFA-6UDRVW8 EFA-8UDRVW8
EFA-4UDRCW8 EFA-5UDRCW8 EFA-6UDRCW8
EFA-4UDUCW8 EFA-5UDUCW8 EFA-6UDUCW8 EFA-8UDUVW8
EFA-4UDUVW8 EFA-5UDUVW8 EFA-6UDUVW8
Specification and size 1.2 meter (4') 1.5 meter (5') 1.8 meter (6') 2.4 meter (8')
Dimensions
(Length x Width x Height)
It's just a fume hood 1220 x 900 x 1400 mm
(48.0" x 35.4" x 55.1")
1525 x 900 x 1400 mm
(60.0" x 35.4" x 55.1")
1830 x 900 x 1400 mm
(72.0" x 35.4" x 55.1")
2440 x 900 x 1400 mm
(96.1" x 35.4" x 55.1")

Additional exhaust ring

1220 x 900 x 1521 mm
(48.0" x 35.4" x 59.9")
1525 x 900 x 1521 mm
(60.0" x 35.4" x 59.9")
1830 x 900 x 1521 mm
(72.0" x 35.4" x 59.9")
2440 x 900 x 1521 mm
(96.1" x 35.4" x 59.9")
Fully open the front glass window frame 1220 x 900 x 1603 mm
(48.0" x 35.4" x 64.7")
1525 x 900 x 1603 mm
(60.0" x 35.4" x 64.7")
1830 x 900 x 1603 mm
(72.0" x 35.4" x 64.7")
2440 x 900 x 1603 mm
(96.1" x 35.4" x 64.7")
Internal dimensions
(Length x Width x Height)
996 x 675 x 1230 mm
(39.2" x 26.6" x 48.4")
1301 x 675 x 1230 mm
(51.2" x 26.6" x 48.4")
1606 x 675 x 1230 mm
(63.2" x 26.6" x 48.4")
2210 x 675 x 1230 mm
(87.0" x 26.6" x 48.4")
structure

outer body

ISOCIDE ™ Epoxy polyester hybrid powder coating galvanized steel
Internal surface layer (default) Esco Resinate ™
Workbench (default) phenolic resin
Front glass window frame parameters Material of front glass window frame Tempered laminated glass and frame fan
Front glass window frame type Vertical or comprehensive level
Angularity 5 ° front angle tilt
The maximum height when the front glass window frame is fully open 740 mm (29.1")

Esco offers a variety of optional accessories to meet application needs

All Frontier Acela fume hoods include a water and gas enhancer installed on the top of the cabinet ™ Remote control device, including two dual plugs (socket code must be specified when ordering).

  • AC power plug and socket
  • Enhanz ™ Remote control of gas-liquid valve
  • Sentinel-XL ™ Airflow alarm device
  • Distillation grid rack
  • water channel
  • worksurface
MCB/ELCB
  • Protect laboratory equipment in case of power failure
  • Ventilation cabinet circuit protection
  • Only applicable to 230V, AC, 50/60Hz cabinet
  • Factory installation; Please specify when placing an order
Ventilation equipment (VK-EBA)
  • Using the cabinet exhaust system to ventilate the bottom cabinet
  • field assembly
  • Air filter (FP-EBAD)
    • Each row of fume hoods requires a set of air filters.
    • field assembly
pdfASHRAE 110-2016 Certificate for EFA 4 ft
pdfASHRAE 110-2016 Certificate for EFA 5 ft
pdfASHRAE 110-2016 Certificate for EFA 6 ft
pdfASHRAE 110-2016 Certificate for EFA 8 ft
Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!