characteristic:
-Efficient and Low Consumption New Design
-Box type construction, suitable for year-round operation
-Single sample bottle 250 ml (borosilicate glass)
-Sample thermoelectric integrated heating and cooling
-The electronic components for controlling the on/off of the fan are built into a lockable electronic box
-Automatic optical detection of fog presence, automatic on/off of sampler
-Durable side air duct blower (pump mode operation) with a long lifespan
-Temperature and humidity detector, analog signal output, built-in in protective louvers
-Temperature controlled shutdown (when below 2 ℃ or above 17 ℃) to avoid fog condensation at 0 ℃ or fan overheating.
-(Optional) Data logger with PCB NES memory to record temperature, humidity, switch time, etc. Programmable and easy to read (such as through terminal program Putty or similar programs)
Technical Description:
Automatic switch control system
Laser fog visibility sensorONED250Detectable visibility of fog. When the visibility remains below a certain set value during a certain period of time, the control circuit will turn on the vacuum pump, and the fog sampler will continue to collect fog samples. On the contrary, control the vacuum pump to turn off and stop sampling.
When the ambient temperature is below2At ℃, fog sampling will also stop to prevent the sampling port from freezing and blocking. Under most meteorological conditions, when the ambient temperature is above17At ℃, there is usually no fog, so no sampling is taken (the specific temperature threshold can be set by the customer).
This automatic switch control system can also prevent possible damage caused by continuous long-term operation of the fan by turning it off.
Sample temperature control
The automatic sample thermoelectric heating and cooling system enables the instrument to operate throughout the year. Ensure that the chemical composition of the sample remains unchanged for a prolonged period of time.
Data logger (optional)
Data logger (built-in) can record the opening of the pump/Basic information such as shutdown, temperature and humidity. Programmable and easy to read (such as through terminal programs)PuttyOr similar programs).
Technical Parameter
Sampler (built-in)
long*wide*High:360*130*260 mm
Weight: make an appointment1.9 Kg
Sampling port: 120*120 mm
Operating temperature:+0…40℃
Sample bottle: 250 mlBorosilicate glass sample bottle
Sampling height: about1800 mm(Base optional)
Instrument size:
long*wide*High:440*750*1090 mm(including blinds and optional fog sensor)
Weight: Approximately70 Kg
Power supply:220/230 V,50/60 Hz,1300 W
Standard configuration:
SAMPLER
Side air duct blower
Sample thermoelectric automatic cooling/Heating system
Solid enclosure (suitable for field work)
Fog detector
warm/humidity sensor
Document materials
Optional configuration:
Sample without thermoelectric automatic cooling/Heating system
standby250 mlGlass sample bottle
Data logger (withPCB NESMemory)
Base
In the main components/English translation
Fog detector
Fog sensor
Temperature sensor with hundred leaf box
Temperature sensor with shelter
control unit
Control unit
data acquisition(optional)
Data logger(optional)
Base (optional)
Stand base (optional)
vacuum pump
Vacuum pump
Sampling cavity
Sample container
Fog sampler
Fog sampler