characteristic:

-Efficient and Low Consumption New Design
-Box type construction, suitable for year-round operation
-Single sample bottle 250 ml (borosilicate glass)
-Sample thermoelectric integrated heating and cooling
-The electronic components for controlling the on/off of the fan are built into a lockable electronic box
-Automatic optical detection of fog presence, automatic on/off of sampler
-Durable side air duct blower (pump mode operation) with a long lifespan
-Temperature and humidity detector, analog signal output, built-in in protective louvers
-Temperature controlled shutdown (when below 2 ℃ or above 17 ℃) to avoid fog condensation at 0 ℃ or fan overheating.
-(Optional) Data logger with PCB NES memory to record temperature, humidity, switch time, etc. Programmable and easy to read (such as through terminal program Putty or similar programs)






Technical Description:

Automatic switch control system

Laser fog visibility sensorONED250Detectable visibility of fog. When the visibility remains below a certain set value during a certain period of time, the control circuit will turn on the vacuum pump, and the fog sampler will continue to collect fog samples. On the contrary, control the vacuum pump to turn off and stop sampling.

When the ambient temperature is below2At ℃, fog sampling will also stop to prevent the sampling port from freezing and blocking. Under most meteorological conditions, when the ambient temperature is above17At ℃, there is usually no fog, so no sampling is taken (the specific temperature threshold can be set by the customer).

This automatic switch control system can also prevent possible damage caused by continuous long-term operation of the fan by turning it off.

Sample temperature control

The automatic sample thermoelectric heating and cooling system enables the instrument to operate throughout the year. Ensure that the chemical composition of the sample remains unchanged for a prolonged period of time.

Data logger (optional)

Data logger (built-in) can record the opening of the pump/Basic information such as shutdown, temperature and humidity. Programmable and easy to read (such as through terminal programs)PuttyOr similar programs).

Technical Parameter

Sampler (built-in)

long*wide*High:360*130*260 mm

Weight: make an appointment1.9 Kg

Sampling port: 120*120 mm

Operating temperature:+0…40

Sample bottle: 250 mlBorosilicate glass sample bottle

Sampling height: about1800 mm(Base optional)

Instrument size:

long*wide*High:440*750*1090 mm(including blinds and optional fog sensor)

Weight: Approximately70 Kg

Power supply:220/230 V50/60 Hz1300 W

Standard configuration:

SAMPLER

Side air duct blower

Sample thermoelectric automatic cooling/Heating system

Solid enclosure (suitable for field work)

Fog detector

warm/humidity sensor

Document materials

Optional configuration:

Sample without thermoelectric automatic cooling/Heating system

standby250 mlGlass sample bottle

Data logger (withPCB NESMemory)

Base




In the main components/English translation

Fog detector

Fog sensor

Temperature sensor with hundred leaf box

Temperature sensor with shelter

control unit

Control unit

data acquisition(optional)

Data logger(optional)

Base (optional)

Stand base (optional)

vacuum pump

Vacuum pump

Sampling cavity

Sample container

Fog sampler

Fog sampler




Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!