VIP member
AKF-1 Capacity Method Karl Fischer Moisture Analyzer
Market quotation: 26800RMB
Product details

1. Product name: Fully automatic volumetric Karl Fischer moisture analyzer
2. Model: AKF-1
3. Range of moisture content determination: 0.001∽100.00%; (10ppm~100%)
4. Titration control accuracy: 0.001ml (20ml high-precision burette)
5. Measurement resolution: 1ppm
6. Measurement repeatability: 99.7% (10mgH20)
7. Sample testing time: tens of seconds to minutes;
8. Method storage: 5;
9. Storage of measurement result data: 60 sets
10. Titration component: piston head, 20ml long-life automatic burette;
11. Valve and pipeline materials: three-way two-way electromagnetic drive control valve, anti-corrosion material pipeline and sealing joint;
12. External electrode: Double platinum plate electrode
13. Display mode: LCD screen (version: Chinese version, English version optional)
14. Auxiliary settings: titration delay, endpoint delay, waste liquid bottle overflow warning, calibration assistance;
15. Operating environment humidity: ≤ 80%
16. Power environment: 110-220V/50HZ
17. Gross weight of the instrument: 5.5Kg

1. The instrument adopts a fully enclosed titration cell with extremely low system drift. It automatically changes solvents and discharges waste liquids to avoid the escape of toxic reagents and the infiltration of environmental moisture; Special nuts and seals are used for pipeline joints, and various bottle caps are designed to accommodate various reagent bottles;
2. High precision titration control technology; Equipped with high-precision piston and titration control technology, the 20ml burette can control an accuracy of less than 1 microliter, ensuring accurate system measurement results; After the burette is filled with reagents and continuously measured, the normal wear and failure rate of the instrument is much lower than that of an instrument that requires the burette to be refilled after analyzing a sample once;
3. Fully automatic measurement, intelligent endpoint algorithm, can use various Karl Fischer reagents, and the measurement results of different Karl Fischer reagents are indistinguishable; The measurement is simple, rapid, and accurate; It can achieve functions such as automatic suction and discharge of Karl Fischer reagent, automatic measurement of drift, automatic calculation of results, solvent suction, waste liquid discharge, and stirring speed regulation;
4. The instrument automatically adjusts the titration speed based on the moisture content and reagent water equivalent, without the need for manual setting of fast and slow drops. The measurement is fast and accurate, with an average sample testing time of about 2 minutes;
Equipped with a suspended transmission component installation method and scientifically structured equipment, the instrument operates with extremely low noise and is easier to maintain; Intelligent fault recognition, automatic shutdown of hardware faults, and protection of important components;
5. Minimalist human-machine interface, equipped with Chinese LCD display screen, real-time display of measuring pump injection volume, detection time, reagent consumption, current water volume, drift and other detection parameters;
6. The instrument displays multiple results simultaneously (moisture content, percentage content, and consumption of Karl Fischer reagent), displays titration dynamic curves, and automatically memorizes measurement results; Save detection data, can be equipped with a dedicated data printer;
7. The instrument has multiple auxiliary detection functions: delayed titration, endpoint delay, custom endpoint, waste liquid bottle overflow warning, calibration assistance, result statistics and storage, etc;