8600 Energy Dispersive X-ray Fluorescence Spectrometer
8600 Energy Dispersive X-ray Fluorescence Spectrometer
Product details

RoHSInstructions,EN71-3Toy instructions,94/62/ECPackaging instructions, F,Cl,Br,ISpecialized detector for halogen-free testing and other instructions

Product Features

18600It is specifically designed for halogen-freeRoHSEN71A product designed in accordance with environmental regulations.

2Breaking the traditional straight line design of instruments, adopting a streamlined integrated design, the instrument is stylish and elegant.

3Adopting the latest technology from the United StatesSi-pinDetector, electrically cooled instead of liquid nitrogen cooled, with small size, accurate data analysis, and low maintenance cost.

4Adopting self-developed technologySESThe signal processing system effectively improves the sensitivity of measurement and makes the measurement more accurate.

5One click automatic testing, simpler and more convenient to use, with a more user-friendly interface.

6Seven types of optical path calibration and collimation systems, automatically switching according to different samples.

7Multiple anti radiation leakage design, radiation protection level belongs to the highest level of similar products.

8Optimize the integrated heat dissipation design to greatly improve the overall heat dissipation performance and ensure the safe operation of core components.

9The unique temperature monitoring technology of the movement ensures the safe and reliable operation of the radiation source, effectively extending its service life and reducing usage costs.

10Multiple instrument accessory protection system, and can be monitored throughout the entire process through software,Make the instrument work more stably and safely.

11ROHSSpecialized testing software, standard window design, user-friendly interface, and easy operation.

12This machine adoptsUSB2.0Interface, effectively ensuring accurate, high-speed, and efficient transmission of data.

Main hardware configuration of the instrument

1 Si-pinElectric cooled semiconductor detector:(Latest detector)

1.1. Si-pinElectric cooled semiconductor detector; resolving power:149±5Electron volt

1.2.Amplification circuit module:Regarding the characteristics of the sampleXRadiation detection; Collect information through detection,Further enlarge.

2 XX-ray excitation device:

2.1.Maximum output of filament current:1mA

2.2 .Belongs to semi consumable components with a service life greater than20000hour

3 High voltage launch device:

3.1.Maximum voltage output:50kV

3.2.minimum5kvControllable adjustment

3.3.Equipped with voltage overload protection

4 Multi-channel analyzer:

4.1.Convert the collected analog signals into digital signals,And provide the processing results to the upper computer software;

4.2 The maximum number of roads: 4096

4.3 Includes signal enhancement processing function;

5Optical path filtering module

5.1 reduceXInterference during the transmission of the radiation path ensures accurate signal reception by the detector;

5.2 Integrate the collimator with the filter;

6 Collimator automatic switching module

6.1 Up to7The selection and caliber are respectively8-1, 8-2, 8-3, 8-4#,6, four, two#.

7 Filter automatic switching module

7.1Free selection and switching of five types of filters.

8 Free combination module of collimator and filter

8.1 Up to dozens of collimators and filters can be freely combined.

9 Automatic selection module for work curve

9.1 Automatically selecting work curves, eliminating manual selection, avoiding human operational errors, and presenting automation and intelligence more perfectly, making operation more humane and convenient.