VIP member
77022AST, 77023ASTec CHIRALDEX B-DM Gas Capillary Chromatography Column
The fixed phase bonded β - cyclodextrin derivative (2,3-di-O-methyl-6-t-butyl silyl) of B-DM capillary column has a wide range of chiral selectivity.
Product details
Product Description:U.S.ASupelcoChromatography DepartmentAstec ® CHIRALDEX ®Gas chromatography columnGCCapillary column, specifications and models includeB-DM,B-DA,B-TA,B-PM,B-PH,B-DPWaiting series.
B-DMFixed phase bonding of capillary columns?β-Cyclodextrin derivatives(2,3-di-O-methyl-6-t-butyl silyl?)With a wide range of chiral choices, it combines withPMandPHStage selectivity, resolving chiral issues of aliphatic, alkene, and aromatic enantiomers.
MAOT = 200℃ (constant temperature line)220℃ (program temperature)
Temperature limit:-10°Cto200 °CIsothermal temperature,The program temperature can be set to220 °C
Through special derivative methods, CHIRALDEX B-DMThe concentration of cyclodextrin significantly increases in the polysiloxane carrier. This fixation is very useful for many free acids and bases.B-DMCan be separated and fully methylatedβMost of the substances separated by cyclodextrin stationary phase,But the degree of separation is higher.B-DMThe selectivity includesB-PMandB-PHApplication of Phase,But the performance is even more outstanding.
B-DMFixed phase bonding of capillary columns?β-Cyclodextrin derivatives(2,3-di-O-methyl-6-t-butyl silyl?)With a wide range of chiral choices, it combines withPMandPHStage selectivity, resolving chiral issues of aliphatic, alkene, and aromatic enantiomers.
MAOT = 200℃ (constant temperature line)220℃ (program temperature)
Temperature limit:-10°Cto200 °CIsothermal temperature,The program temperature can be set to220 °C
Through special derivative methods, CHIRALDEX B-DMThe concentration of cyclodextrin significantly increases in the polysiloxane carrier. This fixation is very useful for many free acids and bases.B-DMCan be separated and fully methylatedβMost of the substances separated by cyclodextrin stationary phase,But the degree of separation is higher.B-DMThe selectivity includesB-PMandB-PHApplication of Phase,But the performance is even more outstanding.
Item number | describe |
77021AST | Astec CHIRALDEX ™ B-DM gas-phase capillary column L × I D.10m×0.25mm, df0.12μm, 1 piece/pack |
77022AST | Astec CHIRALDEX ™ B-DM? Gas capillary column? L×I. D.20m×0.25mm, df0.12μm, 1 piece/pack |
77023AST | Astec CHIRALDEX ™ B-DM gas-phase capillary column L × I D.30m×0.25mm, df0.12μm, 1 piece/pack |
77024AST | Astec CHIRALDEX ™ B-DM gas-phase capillary column? L×I. D.40m×0.25mm, df0.12μm, 1 piece/pack |
77025AST | Astec CHIRALDEX ™ B-DM gas-phase capillary column L × I D.50m×0.25mm, df0.12μm, 1 piece/pack |
Online inquiry