Product Overview: 4-72/79 Carbon Steel Fan
The efficiency and specific A-level of the 4-72 and 4-79 centrifugal fans meet or exceed the A-level standards set by the Ministry of Machinery Industry. Widely used in various large and medium-sized factories, civil buildings, large venues and other ventilated places.
4-72 and 4-79 centrifugal fans are used for general ventilation and air exchange, conveying air or other gases that are not flammable, explosive, or corrosive. The gas is free of viscous substances and contains no more than 150 mg/m of dust and hard particles3.
F4-72/79 is a corrosion-resistant centrifugal fan used for transporting corrosive gases. It can be made of materials such as fiberglass, steel plate, stainless steel, etc.
B4-72/79 is an explosion-proof centrifugal fan used for transporting flammable and explosive gases. The motor is equipped with an explosion-proof motor, made of cast aluminum impeller or non-metallic materials.
FB4-72/79 is a corrosion-resistant and explosion-proof centrifugal fan used for transporting corrosive and flammable gases.
Fan Configuration Table
1. Fan casing: | Carbon steel Q235B (Baosteel) |
2. Fan impeller: | Optional carbon steel impeller, fiberglass impeller, stainless steel impeller, aluminum impeller |
3. Bearing box: | Oil bath bearing box (excluding direct connection type) |
4. Bearing brand: | NSK、SKF、HRB |
5. Transmission group: | American style non knock disassembly and assembly belt pulley imported high tension belt (excluding direct connection type) |
6. Belt brand: | MITSUBOSHI |
7. Motor: | Domestic well-known brands |
8. Pedestal: | Double layer shock-absorbing pedestal stainless steel shock absorber |
9. Protective cover: | Standard belt protection cover, motor rain cover, bearing box cover |
10. Inspection port: | Detachable maintenance port threaded drain outlet |
11. Protective coating: | Two layers of rust prevention spray and one layer of vertical stripe spray |
12. Impeller balance level: | Compliant with ISO1940 standard 2.5mm/s grade |
13. Vibration level of the whole machine: | Compliant with ISO2372 standard 4.5mm/s grade |


-
shock-absorption device
Tianhong fanThe entire series of fans come standard with a double-layer shock-absorbing pedestal and stainless steel shock absorbers to reduce noise and vibration and extend the service life of the fans.
-
impeller
Tianhong fanQ235 steel impeller, SUS304 stainless steel impeller, and explosion-proof motor can be equipped with aluminum impeller.
-
casing
Tianhong fanMade of carbon steel Q235B material, the outer layer is sprayed with anti rust paint and metal fluorocarbon paint, effectively preventing aging and corrosion caused by sun and rain exposure.
-
electrical machinery
Tianhong fanAdopting high-efficiency and energy-saving professional fan matching motors, all of which have passed ISO9001 and national explosion-proof center certification. They can be equipped with BT4, CT4, variable frequency explosion-proof and other high-efficiency energy-saving motors, and are equipped with fiberglass protective covers.
-
Bearing group
Tianhong fanEquipped with NSK, SKF, HRB and other brand bearings, oil bath bearing box, imported Japanese Samsung high tension belt and American style non knock disassembly pulley, all equipped with fiberglass protective cover.
-
shield
Tianhong fanStandard motor rain cover, belt protection cover, and bearing box protection cover to solve outdoor rain and sun protection problems and extend the service life of the fan.






1、 Introduction to Tianhong Commissioned Experimental Laboratory (a large domestic wind turbine inspection laboratory):
1: Our laboratory has passed the qualification review of the Energy Efficiency Labeling Management Center of China National Institute of Standardization and obtained the qualification of Energy Efficiency Testing Laboratory for Ventilation Fan Energy Efficiency Labeling. After the fan products are tested by the center, they can be directly registered online and labeled with energy efficiency labeling based on the test report, and then produced and sold.
2: Our laboratory has 198 quality inspection projects for fan products, and the parameters have passed national laboratory accreditation and metrological certification.
2、 The power performance and noise testing laboratory ensures the accuracy of the results through the following methods:
1. Strictly follow standards such as ISO 5801 (GBT 1236), ISO 13350 (GBT 19843), ISO 5802 (GBT 10178) for design, construction, and testing operations;
2. The aerodynamic performance test adopts advanced multi nozzle method, replacing the traditional pitot static pressure tube to test flow rate, further improving accuracy;
3. The laboratory extensively uses new precision testing equipment and measuring devices;
4. Laboratory equipment and measuring tools have undergone strict calibration and regular re inspection and self calibration;
5. Multiple national level laboratories in China have conducted multiple "same machine inter laboratory comparisons" and participated in the capacity verification activities of ventilation fan testing laboratories carried out by national institutions.

3、 In addition to aerodynamic performance and noise detection functions, the laboratory also has the following testing capabilities:
1. Conduct impeller overspeed test according to JB/T 6445 Industrial Ventilation Fan Impeller Overspeed Test.
2. Conduct fan vibration testing in accordance with standards such as JB/T 8689 "Vibration Testing and Limits for Ventilators".
3. Conduct thrust testing on tunnel jet fans in accordance with the ISO 13350 standard for performance testing of industrial ventilation fans and jet fans.
Ensuring the efficiency of Tianhong's product research and development, reliable quality control, and improving the accuracy and authenticity of technical data.