24217-U, 24205-UvOCOL gas-phase capillary column
Specially designed for volatile organic compounds (VOCs), ensuring better retention and superior separation of volatile substances. Used for direct in
Product details
Designed for volatile organic matter (VOCs(,Ensures better retention and better separation of volatile substances. For direct sampling or combined blow-up capture.
VOCOL ™ Capillary GC Column
Item number
Description
28463-U
20m×0.18mm, df 1.00μm (Supelco)
24129-U
10m×0.20mm, df 1.20μm (Supelco)
24205-U
30m×0.25mm, df 1.50μm (Supelco)
24154
60m×0.25mm, df 1.50μm (Supelco)
24217-U
60m×0.32mm, df 1.80μm (Supelco)
24157
60m×0.32mm, df 3.00μm (Supelco)
25320-U
30m×0.53mm, df 3.00μm (Supelco)
25381
60m×0.53mm, df 3.00μm (Supelco)
25358
105m×0.53mm, df 3.00μm (Supelco)
23313-U
60m×0.75mm, df 1.50μm (Supelco)

Fixed phase: bonded, proprietary fixed phase
≤0.32 mm I.D., 2 μm:~250 °C
≤0.32 mm I.D., ≥2 μm:~230 °C
≥0.53 mm I.D., 2 μm:~250 °C
≥0.53 mm I.D., ≥2 μm:~230 °C
Application: Medium polar column for analysis of volatile organic compounds(VOCs). It has good retention and resolution for strong volatile compounds and can be used for direct samplingGCAnalyze or sweep captureGCAnalysis.
Supelco VocolGas phase capillary column technical parameters
Designed for volatile organic matter (VOCs(,Ensures better retention and better separation of volatile substances. For direct sampling or combined blow-up capture
Applicable toUS EPA 502.2, 524.2, 624, 8240, 8260,?and8021Wait Method
USPCode: None
Fixed phase: bonded, proprietary fixed phase
Temperature Range: Room Temperature-250°C

Supelco VocolGas phase capillary column main application
Medium polar column for analysis of volatile organic compounds (VOCs). It has good retention and resolution for strong volatile compounds and can be used for direct samplingGCAnalyze or sweep captureGCAnalysis.

VOCOLThe gas chromatography column isEPANational standards, tobacco line marking and other methods to designate a dedicated column for volatile analysis. Such as national standardsYC/T 207-2006Determination of Volatile Organic Compounds in Cigarette Bars and Box Packaging Top Air Chromatography andGB-T-5750-2006Volatile substances in standard test methods for living drinking water1,1-Vinyl dichloride(GB/T5750.8-2006:5.1)designated columns.