1、 (Side firing) Leeb Hardness Tester TIME5130- Product Overview:
The (side firing) Leeb hardness tester TIME5130 is a measuring and testing instrument developed based on the Leeb hardness test theory and advanced microelectronics technology for measuring the hardness of metal materials. It can be used for a wide range of metal material tests, especially for measuring the hardness of large, heavy, non removable, small space, different directions, and special parts of workpieces. This Leeb hardness tester displays hardness values digitally, with small size, light weight, simple testing, convenient portability, high inspection efficiency, and minimal damage to the test surface. This Leeb hardness tester can play an important role in ensuring product quality and conducting metal material failure analysis.
2、 (Side firing) Leeb hardness tester TIME5130- Functional features:
The release button of the impact device is located on the side, making operation more convenient;
1.5-inch OLED display screen, 128 × 64 graphic dot matrix, high brightness, high contrast, clear information display;
Equipped with a USB interface for easy connection to a computer;
● It has the function of automatically identifying common impact directions;
Can store the average of 200 measurements;
● The upper and lower limits of the hardness value can be pre-set, and there will be a display prompt if it exceeds the range, making it convenient for users to measure in batches;
Equipped with voltage display and undervoltage prompt, with undervoltage automatic shutdown function;
● There is a software calibration function for indicating values;
● Use 2 AAA type 1.5V (7 #) dry batteries for easy replacement at any time;
● It has an automatic shutdown function without operation, and the duration of automatic shutdown can be adjusted;
According to user requirements, upper computer software can be equipped, and measurement data can be transmitted to the upper computer in Microsoft Word or Excel format, meeting higher requirements for quality assurance activities and management.
Main purpose and scope of application:
Installed mechanical or long-term assembly components;
Mold cavity, heavy-duty workpieces;
Failure analysis of pressure vessels, steam turbine generators and their equipment;
Measuring workpieces with limited space;
● Bearings and other components;
● Material differentiation in metal material warehouses;
Rapid inspection of multiple measurement points on a large scale of large workpieces;
3、 (Side firing) Leeb hardness tester TIME5130- Applicable standards:
JB/T 9378-2001 Chinese Machinery Industry Standard Leeb Hardness Tester
GB/T 17394-1998 National Standard of the People's Republic of China Metal Leeb Hardness Test Method
JJG747-1999 National Metrological Verification Regulations of the People's Republic of China Leeb Hardness Tester
4、 (Side firing) Leeb hardness tester TIME5130- Technical parameters:
The release button of the impact device is located on the side, making operation more convenient;
1.5-inch OLED display screen, 128 × 64 graphic dot matrix, high brightness, high contrast, clear information display;
Equipped with a USB interface for easy connection to a computer;
● It has the function of automatically identifying common impact directions;
Can store the average of 200 measurements;
● The upper and lower limits of the hardness value can be pre-set, and there will be a display prompt if it exceeds the range, making it convenient for users to measure in batches;
Equipped with voltage display and undervoltage prompt, with undervoltage automatic shutdown function;
● There is a software calibration function for indicating values;
● Use 2 AAA type 1.5V (7 #) dry batteries for easy replacement at any time;
● It has an automatic shutdown function without operation, and the duration of automatic shutdown can be adjusted;
According to user requirements, upper computer software can be equipped, and measurement data can be transmitted to the upper computer in Microsoft Word or Excel format, meeting higher requirements for quality assurance activities and management.
|
measurement range |
See table for details 1(170 ~ 960)HLD (17.9-69.5)HRC |
|
D Type high-precision impact device
Indication error and indication repeatability |
See table for details 2 ± 6HLD ( HLD=760 When) |
|
measurement direction |
360° |
|
Range of upper and lower limit settings |
( 170-960 ) HLD |
|
Operating temperature |
|
|
Working Voltage |
3V |
|
power supply |
AAA Type1.5V(7#)Dry battery2section |
|
Communication interface standard |
USB 2.0 |
|
Overall dimensions |
197×66× |
|
heavy quantity |
about |
|
Standard Configuration |
Host1TaiwanAAAType1.5V(7#)Dry battery2Section, small support ring1Only nylon
Brush(I)1Only Leeb hardness block (high value)1block |
|
Optional configuration |
Upper computer software, data cables, various irregular support rings |
