ZetaProbe is an easy-to-use, easy-to-use, and accurate Zeta potential analyzer. For samples with concentrations up to 60% v/v. It can be directly measured without dilution or sample pretreatment, even for paste, gel, cementMaterials that are difficult to measure with other instruments can be directly measured using ZetaProbe.
Traditional measurement methods require dilution of the sample or other processing, which is time-consuming and prone to errors. The patented Multiple Frequency Electro Acoustic technology of ZetaProbe fully automatic Zeta potential analyzer can completely avoid these troubles, and can directly measure the Zeta potential in the original state of the sample, allowing sample concentrations up to 60% by volume. The ZetaProbe instrument has a compact structural design, with a built-in automatic titration device, multifunctional sensors, and highly user-friendly operating software, making the measurement of Zeta potential so simple and fast.
The fully automatic titration device can automatically and quickly provide the isoelectric point (IEP) for acid determination and the selection formula for dispersant or flocculant for quantitative concentration titration. In addition, the ZetaProbe Zeta potential analyzer can automatically correct particle size and double layer distortion, which other instruments cannot achieve. Moreover, the operating software of the instrument is easy to use and powerful, making it very suitable for scientific research and quality control in factories.
Measurement parameters
-potentials
-Dynamic migration rate
-conductivity
-ph value
-temperature
-Isoelectric point (IEP)
CD Company provides a wide range of services to help you fully utilize this powerful new measuring device, ZetaProbe and Acoustic Sizer IIx, which can be applied to optimize control in factories, QA/QC, The use of scientific research or academic institutions.
Main application areas
·ceramics | ·Edible colloids | ·Biological colloid | ·Homogenization control |
·Paint and Ink |
·latex |
·paper coating |
·Catalyst and Boiling |
·Coal slurry |
·adhesive |
·pharmaceutical production |
·grind |
·paint |
·Mineral processing |
·Filtration/Dehydration |
·Polishing composite materials, etc |
·Natural milk |
·clay |
·Wet grinding/grinding |
|
·phosphor | ·mineral | ·Surface coating control |
Application Cases
Optimization of dispersant dosage: Adding polymer electrolyte DarvanC to alumina suspension, it was found that the value of Zeta potential is related to the amount of polymer electrolyte DarvanC added and pH
Accurate isoelectric point (IEP) measurement: The same IEP is 6.9 instead of 7.8, and the Zeta potential values of two samples with different concentrations are almost the same at different PH.
Titration of titanium dioxide suspension sample in 0.1M potassium chloride solution using ZetaProbe and automatic background correction