Jiangsu Zhongneng Instrument Technology Co., Ltd
Home>Products>ZN310A high static pressure transmitter
ZN310A high static pressure transmitter
ZN310A high static pressure transmitter
Product details
ZN310A high static pressure transmitter

ZN310AHigh static pressure transmittercharacteristic

Excellent performance and stability
The ZN series adopts monocrystalline silicon resonant sensor technology. Monocrystalline silicon does not exhibit hysteresis in response to changes in pressure or temperature, making it an ideal material. Monocrystalline silicon resonant sensors minimize the effects of overvoltage, temperature changes, and static pressure, providing unparalleled long-term stability.

Small and lightweight design
Due to the use of ASIC amplifier design to reduce packaging size, as well as the miniaturization of membrane box structure and flanges, the weight of this model has been reduced to half of the original model. ASIC design not only reduces the number of parts, but also improves the reliability of the amplifier.

Fieldbus communication capability
Fieldbus is a bidirectional digital communication system, an innovative technology for configuring instrument control systems, and also a promising replacement product for the widely used standard 4-20mA analog communication in field instruments.
The ZN series offers two fieldbus modes, FOUNDATION fieldbus low voltage mode and PROFIBUS PA equipment, to achieve collaborative work between Yokogawa Electric and other suppliers. In terms of software, the JT series uses two AI function blocks to calculate differential pressure and static pressure, thereby achieving flexible instrument configuration.

ZN31ZN310A Absolute Pressure Transmitter Specification ZN310A Absolute Pressure Transmitter ZN310A Absolute Pressure Transmitter
L film box M film box A film box
Measurement range 0~10kPa abs
(0~2.9521inHg abs) 0~130kPa abs
(0~38inHg abs) 0~3MPa
(0~430psia)
Measurement range: 0.67~10kPa
(0.2~2.95inHg) 1.3~130kPa
(0.382~38inHg) 0.03~3MPa
(4.312~430psi)
Accuracy ± 0.21% ± 0.151% ± 0.151%
Protection level IP67, NEMA 4X, And JIS C0920 immersion proof type
Explosion proof specification FM, CENELEC ATEX,CSA,IECEx
Output signal 4-20mA DC or FOUNDATION? Fieldbus or PROFIBUS PA two-wire digital communication
Power supply BRAN and HART: 10.5~42V DC (intrinsic safety type: 10.5~30V DC)
Fieldbus: 9~32V DC (Intrinsic Safety Entity Mode 9~24V DC, Intrinsic Safety FISCO Mode 9~17.5V DC)
Environmental temperature -40~85 ℃ (-40~185 ℉) (ordinary type)
-30~80 ℃ (-22~176 ℉) (with built-in indicator)
Process temperature M and A membrane box: -40~120 ℃ (-40~248 ℉) (ordinary type)
L film box: -40~100 ℃ (-40~212 ℉) (ordinary type)
Maximum overvoltage 500kPa abs
(72psia) 500kPa abs
(72psia) 4.5MPa abs
(645psia)
Install 2-inch pipe installation
Material of the liquid receiving component: membrane box SUS316L (membrane: Hastelloy C-276)
Container flange SUS316
Aluminum alloy or SUS316 stainless steel shell (optional)


ZN310A Absolute Pressure Transmitter Selection Table

Basic specification code ZN310A-DMS5A-92NN

Item 1:

Output signal - D 4-20mA DC/with digital communication (BRAN protocol)
-E 4-20mA DC/with digital communication (HART protocol)
-F FF fieldbus communication

Item 2:

Measurement range (capsule) M 1.3-130KPa abs (9.6-960mmHg abs)
A 0.03-3MPa abs(0.3-30kgf/cm2 abs)

Item 3:

Material S of the liquid receiving component
JIS SCS14A JIS SUS316L JIS SUS316

Item 4:

Process interface 0 without process connector (Rcl/4 internal thread on chamber flange)
1 Rcl/4 internal thread process joint
2 Rcl/2 internal thread process joint
3 l/4NPT internal thread process joint
4 l/2NPT internal thread process joint
5. No process joint (1/4NPT internal thread on the chamber flange)

Item 5:

Bolt and nut material A JIS SCM435 130KPa absolute pressure (960mmHg absolute pressure) 3MPa (30kgf/cm2 absolute pressure)
B JIS SUS630 130KPa absolute pressure (960mmHg absolute pressure) 3MPa (30kgf/cm2 absolute pressure)
C JIS SUH660 130KPa absolute pressure (960mmHg absolute pressure) 3MPa (30kgf/cm2 absolute pressure)

Item 6:

Installation method -2 vertical piping connection, right high pressure, upper installation process joint
-3 vertical piping connections, high pressure on the right, lower installation process joint
-6 Vertical piping connections, left high pressure, upper installation process joint
-7 Vertical piping connection, left high pressure, lower installation process joint
-8 horizontal piping connections, high pressure on the right side
-9 horizontal piping connection, high pressure on the left side

Item 7:

Electrical interface 0 G1/2 internal thread, one electrical interface
2 1/2NPT internal thread two electrical interfaces without blind plugs
3 Pg13.5 internal thread two electrical interfaces without blind plugs
4 M20 internal thread with two electrical interfaces, no blind plugs
5 G1/2 internal thread two electrical interfaces, one blind plug
7 1/2NPT internal thread two electrical interfaces, one blind plug
8 Pg13.5 internal thread two electrical interfaces, one blind plug
Two electrical interfaces with 9 M20 internal threads and one blind plug

Item 8:

Hidden Display Table D Digital Display Table
E digital display strap measurement range setting button
N None

Item 9:

Installation bracket A JIS SECC 2 "pipe installation (flat type)
B JIS SUS304 2 "pipe installation (flat type)
C JIS SECC 2 "Pipe Installation (L-type)
D JIS SUS304 2 "Pipe Installation (L-type)
N None

3、 Additional functions of ZN310A absolute pressure transmitter

Item 1:

Explosion proof and intrinsic safety types are not specified
NF1 NEPSI Explosion proof License: d Ⅱ CT6 Environmental Temperature: -40-60 ℃ Electrical Interface: 1/2NPT
FF1 FM Explosion proof Permit C1: I-II&III Div 1&2, Gps. B, C, D, E, F&G NEMA 4X Temperature: C1:T6
FF15 FM Explosion proof License C1: I-II&III Div 1&2, Gps. B, C, D, E, F&G NEMA 4X Temperature: C1:T6
KF1 CENELEC (KEMA) Explosion proof License: EExd Ⅱ CT4 T5、T6
KF5 CENELEC (KEMA) Explosion proof License: EExd Ⅱ CT4 T5、T6
CF1 CSA Explosion proof License C1: I-II&III Div, 1&2, GPS, B, C, D, E, F,&G ENCL: Type4X Temperature: CI:T4、T5、T6
CF15 CSA Explosion proof License C1: I-II&III Div, 1&2, GPS, B, C, D, E, F,&G ENCL: Type4X Temperature: CI:T4、T5、T6
NS1 NEPSI intrinsic safety license: ia Ⅱ CT4 environmental temperature: -40-60 ℃ electrical interface: 1/2NPT
FS1 FM intrinsic safety license intrinsic safety C1: I-II&III Div, 1&2, GPS, B, C, D, E, F,&G non combustible C1: I-II&III Div, 1&2 Gps、B、C、D、E、F&G
KS1 CENELEC (KEMA) intrinsic safety license: EEx ia Ⅱ CT4
CS1 CSA intrinsic safety license: C1: I-II&III Div, 1&2, Gps, A, B, C, D, E, F&G ENCL: Type4X Temperature C1: T4
FU1 includes FF1 and FS1
KU1 includes KF1.KS1 and N-type KEMA, N-type EX nA Ⅱ CT4
CU1 includes CF1 and CS1
SU1 SAA explosion-proof and intrinsically safe with spark free Ex d Ⅱ CT6/T5/T4 IP67, Ex ia Ⅱ CT4 IP67, Ex n Ⅱ CT4 IP67
KS5
CENELEC (KEMA) intrinsic safety explosion-proof: [Entity mode]: EEx ia Ⅱ CT4; [Fisco mode]: EEx ia Ⅱ CT4/EEx ia Ⅱ BT4

Item 2:

Explosion proof sealing joint not specified
G71 Connection Port: 1/2NPT Applicable Cable Outer Diameter: Φ 8.5 ± 0.5 (1 piece)
G72 Connection Port: 1/2NPT Applicable Cable Outer Diameter: Φ 8.5 ± 0.5 (1 piece)
G81 Connection Port: 1/2NPT Applicable Cable Outer Diameter: Φ 8.5 ± 0.5 (2 pieces)
G82 Connection Port: 1/2NPT Applicable Cable Outer Diameter: Φ 8.5 ± 0.5 (2 pieces)

Item 3:

Painting: Color change or painting change not specified
P1 color change only applies to the transmitter housing Munsell symbol code: N1.5, black
The P2 color change is only applicable to the transmitter housing Munsell logo code: 7.5BG4/1.5 green
P7 color change only applies to transmitter housing metal silver
X1 paint change epoxy tree baking paint

Item 4:

Lightning protection device not specified
A transmitter power supply voltage: 10.5-32V DC (intrinsic safety type: 10.5-30V DC) Maximum allowable current: 6000A (1X4 μ S), repeated 1000A (1X40 μ S) 100 times

Item 5:

Prohibition of oil treatment or prohibition of water and oil treatment not specified
K1 degreasing and cleaning treatment
K2 degreasing and cleaning treatment, and the membrane box is filled with fluorine oil, with a usage temperature of -20-80 ℃
K5 degreasing, washing and drying treatment
K6 degreasing, cleaning, and drying treatment membrane box filled with fluorine oil, operating temperature -20-80 ℃

Item 6:

Calibration unit not specified
D1 P correction (Psi unit)
D3 bar calibration (in bar units)
D4 M correction (kgf/cm2)

Item 7:

The sealing treatment of SUS630 nuts is not specified
Surface coating of SUS630 bolts and nuts for Y fastening chamber flange (liquid silicone rubber)

Item 8:

Long exhaust plug not specified

U
Total length: 112mm (standard type: 32mm)

Item 9:

High precision unspecified
HAC accuracy: ± 0.075%

Item 10:

130Pa abs {lmmHg abs} certification does not specify
S1 minimum input pressure: 130Pa abs (1mmHg abs) within the calibration range

Item 11:

Output set to low side or NAMUK NE43 unspecified when CPU exception occurs
C1 low side: ≤- 5%(3.2mA DC)
C2 (NAMUK NE43) [output signal 3.8-20.5mA] fault alarm output -5%, below 3.2mA
C3 (NAMUK NE43) [output signal 3.8-20.5mA] fault alarm output 110%, above 21.6mA

Item 12:

Stainless steel amplifier housing not specified
E1 amplifier housing material: SCS14A stainless steel (equivalent to SUS316L cast stainless steel or ASTM CF-8M)

Item 13:

Quick response unspecified
F1 refresh time: ≤ 0.125 seconds Response time (including minimum damping time constant): up to 0.3 seconds

Item 14:

PID/LM function not specified
LC1 PID control function, Link Master function

Item 15:

Configuration not specified
R1 User Configuration Software

Item 16:

Gold plated film not specified
A1 sealing membrane gold-plated

Item 17:

Container flange option not specified
N1 without exhaust plug
N2 N1 and without process joints, with DIN 19213 7/16 inch x 20 internal threads (installation threads) machined on both sides of the chamber flange, and blind plugs on the rear side
N3 N1, N2 chamber flange, diaphragm, body, and blind plug accessory manufacturing certification

Item 18:

Stainless steel license plate not specified
N4 JIS SUS304 stainless steel tag plate fixed on the transmitter

Item 19:

Accessory manufacturing certificate not specified
M01 chamber flange
M11 chamber flange, process joint

Item 20:

Pressure test leakage test certificate not specified
T04 L membrane box test pressure: 50KPa test fluid nitrogen retention time of 10 minutes
T03 A membrane box test pressure: 3MPa test fluid nitrogen retention time 10 minutes 0A absolute pressure transmitter specification