overview
The YN610 series motor protector is -A comprehensive low-voltage motor protection device. Capable of various voltage and current protection functions in engineering applicationsThe functions of switch input, two-way RS485 communication, and analog output provide the most economical, effective, and reasonable means for industrial production process control and distribution automation. Establish a safe, reliable, simple, fast, and powerful system for motor protection, measurement control, management, and communication that meets fieldbus requirements for users. The product complies with the electromagnetic compatibility standards IEC61000-4, 2-3-4-5-5-8-11, and level 4.
characterization
• Three phase current measurement function
• Zero sequence or leakage current measurement function
• Three phase voltage measurement function
• Complete motor voltage and current protection
• Auxiliary power supply AC85V-450V/DClOOV~SSOV supports power supply for zero wire motor applications
• Support local/remote communication control for start stop and forward/reverse start, Y/1::,. Multiple types of startup, including startup
• LCD display, on-site setting of protection control parameters
• Easy and flexible installation/maintenance
• Can be networked with mainstream PLCs and DCS
• Can connect to MODBUS field industrial bus to achieve network communication
• Design license according to relay protection standards
• Three proof treatment of circuit board supports use in harsh environments
Compliant with standards
YN610 series products have strong electromagnetic compatibility and a complete electromagnetic compatibility design, suitable for use in strong electrical interference environments
Naming meaning
FEATURES
• Real time measurement function Ua Ub、Uc、la、lb、IC、IO、P、Q、S、COSF、Freq、Ep、Eq
• Switch input: 10 switch inputs
• Switching output: 6-channel switching output
• LED indication: 6-way LED lights indicate motor operation, faults, and communication
• Ao transmission: 2-channel 4-20mA output, load 5500ohm
• Communication: 2 RS485 channels, supporting standard Modbus RTU
• relay protection
TECHNICAL INDEX
Product Example
terminal diagram
Typical applications
Protection startup mode
After the device is activated, DO3 closes and the start button SB2 is pressed. KM1 coil is powered on, and the motor starts. When a fault trips, DO3 disconnects, KM1 coil loses power, and the motor stops. Press SB1 to stop
Direct startup mode
Bidirectional startup mode
Bidirectional quick action mode
Resistance voltage reduction starting method
Star delta relay starting method
Star delta relay open-loop starting method
Star delta relay closed-loop starting mode
Self coupling voltage reduction starting mode