Intelligent lighting controller
model: XY-0208-LD
1 overview
XY-0208-LD(Light controller with LCD display)The intelligent street lamp controller adopts computer control technology and uses multiple sets of timers to control the lights on sitePLCImplement intelligent control of the lamp through communication interfaces. Intelligent controllers are widely used in lighting systems, building electrical control, and other fields such as industrial, commercial, and civil buildings. They are also suitable for fire electrical control and protection systems such as fire fans and fire pumps in modern buildings. They are widely used in public lighting environments such as municipal roads, highways, bridges, tunnels, underground garages, gardens, docks, sightseeing lights, sports plazas, amusement parks, advertising light boxes, and specialized lighting environments such as office buildings, homes, and schools. Applicable types of lighting fixtures: high-pressure sodium lamps, low-pressure sodium lamps, metal halide lamps, high-pressure mercury lamps, fluorescent lamps, and all other gas discharge lighting fixtures. Using a controller can effectively save resource consumption, reduce waste, and achieve the Internet of Things.
II Functional Features
1. Adopting advanced foreign microprocessor chips, it has high reliability, small error, and strong stability.
2. Equipped with power-off data protection, the clock operates continuously without the need for battery replacement, maintaining clock operation for over ten years.
3. 32Group working mode: The lighting time can be set by the user, with a range of00:00to23:59The turning off time can be set by the user, with a range of00:00to23:59.
4. Equipped with automatic/Manual conversion is convenient for the maintenance of electrical equipment or the needs of major celebrations.
5. Strong anti-interference ability, high-power relay output, can be connected220VContactor or or380VContactors have a long service life.
6. Can be equipped with light control and used in conjunction with time. (Please indicate with light control when ordering)
7. LCD display with 8 buttons;
8. Equipped with fully open and fully closed buttons;
9. Equipped with fully open and fully closed input terminals;
10. Equipped with fire linkage24VSignal, linkage feedback interface dry contact signal;
11. Power off memory function;
12. Remote centralized control and on-site control
13. Emergency manual control
14. Panel time setting and software time setting
15. Panel load status display and software settings
16. Can be equipped with external illumination detection and human infrared microwave induction
17. Wireless control can be added;
18. Standard rail installation
III Technical Parameter
1. Working power supply:direct-current12V DC ,electric current1A ;
2. operation temperature:- 10-65Celsius;
3. Overall Power Consumption:Standby less than3W ;Work less than6W ;
4. Timing error:30S/Year
5. Control interval:24Hour;
6. Number of time periods:32A timer;
7. Work schedule: daily/weekly/once a day
8. Timer: Maximum32A timer;
9. Communication port:RS485interface,default:Baud rate9600, N ,8,1,address1;
10. Communication protocol:modbus RTU
11. External dimensions :90x100x65mm
4 Introduction to Panel and Wiring
Ø Button Description
1. 《 Up button, used for option selection
2. 》Move down button, used for option selection
3. ∧ Add button, used for numerical addition
4. ∨ Minus button, used for numerical subtraction
5. ENTConfirm button, used for option confirmation
6. ESCCancel button, used to return without saving
7. ON Fully open button, used to close all relays and turn on all lights
8. OFFFull off button, used to disconnect all relays and turn off all lights
Ø pilot lamp
1. Operation indicator light, normal 1Shining once every second or so;
2. Communication indicator light, used for communication indication;
3. Fire indicator light, used for firefighting purposes24VInput instructions;
Ø LCD screen Used to display menus and numerical values
Ø Output terminal description
11
N
) Working power supply:DC12V Connect separately12V+,GND, communication220VPower supply usageL,NTerminal.
2) communicationRS485:D+(A),D-(B);
3) Fire feedback switch:NO COMRelay normally open
4) Photosensor:S- S+;
5) Fire start interface:24V+,24V-;
6) External all on/off interface: fully open, fully closed, common terminal;
7) First switch:NO1 CM1 Relay normally open and common terminal;
8) Second switch:NO2 CM2 Relay normally open and common terminal;
9) Third switch:NO3 CM3 Relay normally open and common terminal;
10) Fourth switch:NO4 CM4 Relay normally open and common terminal;
11) Fifth switch:NO5 CM5 Relay normally open and common terminal;
12) Sixth switch:NO6 CM6 Relay normally open and common terminal;
13) Seventh switch:NO7 CM7 Relay normally open and common terminal;
14) Eighth switch:NO8 CM8 Relay normally open and common terminal;
5 Introduction to LCD Menu
1) Start screen
2) main interface
main menu 0 Add:001 HH:MM:SS 1* * * * * * 6 7* * * * * * 12 YYYY-MM-DDweek01 explain Add:Device communication address,current time:time:divide:second The current status of the light *service, 0light off Display on each line6The status of a light;Display in total12A lamp current date,week
set timer 4 timer: 1-32 Status: Enabled/Deactivate Repeat: Every day/every week/Single time/ Date:2018-07-05 Time:18:30 Action: ************ Confirm return Manual switch5 Open:1-12 close:1-12 System Reset return explain press “<”Button or “>”key Select project settings timer:press∧∨ Modified Timer,press“>”Press button down state:Enable the current timer repeat:Timer working mode; date:Single work mode displays date,Display the week on a weekly basis Set timer time:18:30 action(Display the current relay number) press∧∨ Fully open or fully closed Select a single relay to enable,press∧∨ key on or off,pressENTNext relay pressENTButton modification return,pressESCPress the button to return without saving explain press “<”Button or “>”key Select project settings open:press∧∨ Select relay switch channel pressENTKey execution close:press∧ ∨ Select relay switch channel pressENTKey execution System Reset: pressENTPress the button to reset to factory settings return pressENTButton modification return,pressESCPress the button to return without saving
VI Usage
(1) Device address modification
(II) Modify system time
pressENTkey enter1menu
(3) Time:20:15:00 <
1) time:> 20:15:00 < time: 20:15>00 < time: 20>15:00 <
2) pressENTChoose to modify in minutes or seconds
3) date: 2018>07:23 < < date:> 18:07:23 <
4) press<perhaps>Select the date for modification
5) press∧∨ Modify the size of the selected data
6) pressENTChoose to modify year, month, or day
7) date: 2018:07>23 < <
8) Then select 'modify' and return
9) Week:06 < <
10) Or pressESEReturn without saving
(1) set timer
1) Press on the main interfaceENTEnter the settings menu
2) press<perhaps>Press the button to select timer settings,Enter the timer settings menu
3) Select Timer0-31,maximum32timers;
4) state:Select Enable,Enable,timer,
Time for relay activation
Deactivate:The relay does not operate when the time is up.
5) Repeat: Every day/every week/Single time
Select working mode
every day:Daily time until relay action.
every week:Below are options for weekly selection1-7Working hours;
Single time:setting year,the moon,sun,Hour, minute, second,Time to Relay
action.Only work once.
6) time:Time of relay action;
7) action:Select the relay that will activate when the timer expires
select
8) after that press ∧∨ Modify* On or off0
9) pressENTSelect the next relay ,common9Relays
10) final selection Confirm return
11) Timer time up,Relay automatically turns on or off the light.
(II) Set examples
1) give an example every day18: thirtyTurn on all the lights,every day6:00Turn off all lights
2) analysis:use2timers,Like a timer0 18: thirtyTurn on all the lights ,timer1 6: 00Turn off all lights
Ø timer0 18:30fully open set up
3) pressENTenterSet menu1
4) press<perhaps>Press the button to select and set the timer,Press the confirm buttonENT
5) Enter the timer settings menuset timer4-1
6) press<perhaps>key Select Timer
7) Select Timer: 0press ∧∨ Modify
8) press<perhaps>key Select Status
9) Status: Enabled press ∧∨ is modified to enable
10) press<perhaps>key selective repeat
11) Repeat: Every day press ∧∨ is modified toevery day
12) press<perhaps>key Timing
13) Time:18:30 :00 < 1 ************ 12 <
14) press When modifying ∧∨:divide:second
15) pressENTKey selection time,divide,second
16) Select the third line,Lamp switch operation
17) press ∧∨ is modified to open*
18) pressENTPress the button to select the next relay
19) 9Relays Select all as*********
20) Select confirm and return,pressENTkey
21) 18:30fully open timer0 Settings completed
Ø timer1 6:00Fully closed set up
1) pressENTenterSet menu1
2) press<perhaps>Press the button to select and set the timer,Press the confirm buttonENT
3) Enter the timer settings menuset timer4-1
4) press<perhaps>key Select Timer
5) Select Timer: 0press ∧∨ Modify
6) press<perhaps>key Select Status
7) Status: Enabled press ∧∨ is modified to enable
8) press<perhaps>key selective repeat
9) Repeat: Every day press ∧∨ is modified toevery day
10) press<perhaps>key Timing
11) Time:>06:30 :00 <
12) press When modifying ∧∨:divide:second
13) 1 0000000000 12 <
14) Select the third line,Lamp switch operation
15) press ∧∨ is modified to open*
16) pressENTPress the button to select the next relay
17) 9Relays Select all as0000000000
18) Select confirm and return,pressENTkey
19) 06:00Fully closed timer1 Settings completed
1 communication protocol
1. Communication protocol supportmodbus RTU;
Default Address1, baud rate9600,N(No verification),8(8Digit data),1(1Stop position)
2. RELAY CONTROL Use function code5Or function code0FRead the relay status usage function code1
Register address |
thoroughfare name |
Data investigation |
|
0 |
auxiliary word for ordinal numbers1Road relay |
close:01 05 00 00 FF 00 8C 3A |
|