Shanghai Liancheng Pump Industry Co., Ltd
Home>Products>WQ Engineering Sewage Submersible Pump
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    17502143888
  • Address
    1st Floor, Building 13, 1881 Zhengbo Road, Fengxian District, Shanghai
Contact Now
WQ Engineering Sewage Submersible Pump
The medium transported by the WQ engineering sewage pump is normal temperature slurry (less than 40 degrees), with a pH value between 6-8. The magazin
Product details

product overview
The medium transported by the WQ engineering sewage pump is normal temperature slurry (less than 40 degrees), with a pH value between 6-8. The magazine content ratio of sewage and sewage submersible pumps is 20%, and the particle size is not greater than 3.5mm. The magazine content ratio of unobstructed submersible pumps is 45%, and the particle size is not greater than 18mm

Product Features
The product is non clogging, anti winding, small in size, compact in structure, and highly efficient. It can pump clean water as well as liquids containing particles and magazines. It has oil leakage, overload, undervoltage, and phase loss alarm systems, effectively protecting safe operation.

application
Widely applicable for the drainage and irrigation of sewage in construction sites, coal mines, metallurgy, printing and dyeing, textiles and other occasions, and can also be used for the drainage and irrigation of clean water.

Model Meaning
For example: WQ9-22-2.2
WQ Engineering Sewage Pump
9-Flow rate (m3/n)
22 Head (m)
2.2- Motor power

Product model
Supporting pipe diameter (mm)
Maximum external dimensions
Speed (r/min)
Height (mm)
Width (mm)
WQ12.5-15-1.5
50
489
220
2860
WQ45-9-2.2
80
520
308
2860
WQ20-16-2.2
65
527
265
2860
WQ9-25-2.2
50
516
292
2860
WQ65-8-3
100
580
356
2860
WQ25-16-3
65
537
265
2860
WQ15-28-3
50
450
320
2860
WQ65-12-4
100
580
356
2860
WQ40-15-4
100
547
369
2860
WQ15-35-4
50
550
321
2860
WQ12-40-4
50
550
322
2860
WQ15-42-4L
50
2860
WQ65-16-5.5
100
655
340
2860
WQ40-20-5.5
80
620
361
2860
WQ18-50-5.5
50
720
456
2860
WQ45-22-7.5
80
635
293
2860
WQ40-30-7.5
80
635
293
2860
WQ20-40-7.5
65
796
314
2860
Troubleshooting:

Fault phenomenon

Cause analysis

Exclusion method

Insufficient traffic

Or no water will come out

1. Impeller rotation error

2. Is the valve open and intact

3. The pipeline is blocked

4. Low speed

5. Head too high

6. The density of the pumping medium is relatively high

7. High viscosity of the medium

8. Damaged sealing ring (at the mouth ring)

1. Adjust the rotation direction of the impeller

2. Check, repair, and eliminate

3. Clean up debris

4. Check electrical equipment and circuits

5. Change the pump or reduce the head

6. Dilute with water to reduce concentration

7. Reduce viscosity

8. Replace

Unstable operation

1. Unbalanced impeller

2. Bearing damage

1. Send to the manufacturer for replacement or calibration

2. Replace the impeller

The pump cannot start

1. Lack of phase

2. Impeller stuck

3. Winding, connector or cable open circuit

4. Stator winding burnt out

5. Electrical control malfunction

1. Check the circuit for repair

2. Remove debris

3. Use an ohmmeter to check and repair

4. Repair and replace the winding

5. Repair or replace

Excessive current

1. Low working voltage

2. Pipeline and impeller blockage

3. Transporting liquids that have passed or have high viscosity

4. Using a lift that is too high

1. Adjust the working voltage

2. Clean the pipeline and replace the winding

3. Change density or viscosity

4. Reduce traffic and increase traffic

Low insulation resistance

1. Leakage at the power supply terminal of the cable

2. Cable damage

3. Mechanical seal wear leads to leakage

4. Failure of each O-ring seal

5. The casing is corroded by the medium and leaks water

1. Tighten the compression nut

2. Replace

3. Replace

4. Replace

5. Repair



Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!