Brief introduction
AmericaUniBestYoubaida Group Co., LtdX-MetGas 6000 CEMSThe system is a highly ranked monitoring technology instrument for heavy metal flue gas emissions. It has been continuously operating for many years in monitoring heavy metal flue gas emissions, with long-term reliability and only requiring maintenance once a month.
X- MetGas6000As an online testing method for environmental monitoring, it is an alternative to manual methods for discontinuous monitoring of heavy metal pollution sources and on-site heavy metal hazards. It can be conducted regularly and continuously in the United StatesEPAmethod29The required heavy metal testing and analysis of heavy metal raw material gases.XRFThe method is a non-destructive testing technique that allows for sample preservation and reanalysis. The instrument also compares the excess, blank, and flow rate of each sample with the standard sample. This device is recognized by the environmental protection department for various heavy metalsCEMSSystem.
2、 Product principle
AmericaUniBestYoubaida Group Co., LtdX- MetGas6000The multi heavy metal online monitoring system is a sampling system based on a disc belt filter and adopted from the United StatesEPA IO 3.3Non destructive nature of the methodXFluorescence ray principle detection technology (i.eXRF)Automated Multi MetalsCEMSSystem. The method of capturing samples using an active filter membrane was employed to collect the samples. At the beginning of this process, the constant velocity flue gas sample was taken from the digestion chamber and extracted through a chemical reaction filter. Gas phase metal deposits on the active reaction membrane, and the deposited sample is automatically processed by the built-in systemXRFInstrument for analysis. At the same time, the next sample will continue to be collected. existX- MetGas6000In the system, in addition to daily self checks15Sampling and analysis are carried out simultaneously and continuously outside the second.
3、 Main features
1、 useEPA IO 3.3Non destructive nature of the methodXFluorescence ray principle for determining heavy metals in particulate solid matter in the air
2、 all-weather24Hour continuous automatic sampling, sampling analysis time interval15-240Minutes optional
3、 And simultaneously analyze up to in the ambient air online23Plant heavy metal elements and display their respective concentrations, store historical data, and generate data reports
4、 Monitoring element: Can simultaneously detect silverAg, arsenicAs, JinAuBariumBaCadmiumCdChromiumCr, CalciumCa, cobaltCoCopperCuAntimonySbPotassiumK, IronFeGalliumGa, MercuryHgManganeseMnNickelNi, leadPbPalladiumPdSeleniumSe, tinSnThalliumTlVanadiumVZincZn
5、 Non destructive analysis of samples, no need to process the filter membrane on site
6、 Measurement range:0-10 mg/dscm(Dry standard cubic meterDry standard cubic meter), report results every fifteen minutes
7、 Accuracy: achievable95%
8、 Accuracy: achievable98%
9、 Linear: correlation coefficient greater than0.98
10Lower detection limit:ngLower detection limit(sampling60minute)
11Sampling flow rate:16.7 lps(Rising)/Seconds)
12Provide storage of monitoring data, easy transmission and processing of on-site data to the on-site data acquisition system, andEXCELTable Output
13Reliable data: including daily sample exceedance, blank correction, calibration of various metal elements, flow calibration, and other functions
14Automatic alarm and control function
15Remote data transmission and control
16Equipment supporting data analysis and management software
17Open communication protocol
18Accurate, reliable, and easy to use,EPAapprove
19Working environment temperature:25±5℃Upper limit of relative humidity95%;
20Power supply:220V±10%,50HZ
4、 Technical indicators
1、 Basic configuration: analyzer host, samplerPM2.5、PM10Cutting headTSPCutting head, pump, and control system, etc
2、 sample time(Min):15
3、 sample flow(lpm):1.00
4、 sampling volume(m3):0.015
5、 Filter membrane: active
6、 Filter membrane density(mg/cm2):4
7、 Detector:SDD
8、 Anode tube:Rh
9、 Tube power supply(Watts):50
10Number of triggering conditions:3
5、 Application Fields
Mainly used for online monitoring of heavy metal pollution sources in the following air and flue gas: garbage incinerators (hazardous waste, sewage, municipal, medical), cement plants, lime plants, foundries, coal-fired power plants, industrial kilns and boilers, small and medium-sized metal smelters, etc.
VITechnical Parameter
X-MetGas 6000Low detection limit of various heavy metal online monitoring systems(µg/m3)
Serial Number |
element |
atomicity |
Lower detection limit(µg /m3) |
1 |
Crchromium |
24 |
0.20 |
2 |
Mnmanganese |
25 |
0.20 |
3 |
Feiron |
26 |
0.80 |
4 |
Cocobalt |
27 |
0.25 |
5 |
Ninickel |
28 |
0.25 |
6 |
Cucopper |
29 |
0.40 |
7 |
Znzinc |
30 |
0.20 |
8 |
Asarsenic |
33 |
0.10 |
9 |
Seselenium |
34 |
0.10 |
10 |
Brbromine |
35 |
0.40 |
11 |
Srstrontium |
38 |
0.25 |
12 |
Agsilver |
47 |
4.50 |
13 |
Cdcadmium |
48 |
2.40 |
14 |
Sntin |
50 |
90.00 |
15 |
Sbantimony |
51 |
6.00 |
16 |
Bapalladium |
56 |
91.00 |
17 |
Hgmercury |
80 |
0.30 |
18 |
TIthallium |
81 |
0.30 |
19 |
Pblead |
82 |
0.50 |
7、 Similar products
1、 AmericaUniBestYoubaidaPortable MetalSafeHandheld trace heavy metal analyzer
2、 AmericaUniBestYoubaidaMetalSafe ProProfessional level sequencing batch trace heavy metal analyzer in laboratory
3、 AmericaUniBestYoubaidaMetalGuardType online water quality warning trace heavy metal analyzer
4、 AmericaUniBestYoubaidaMetalAlertType online water total arsenic, cadmium, chromium, copper, iron, mercury, manganese, nickel, lead, zinc analyzer
5、 AmericaUniBestYoubaidaX-MetGas ™ 6000-AirType online environmental air heavy metal monitoring instrument
6、 AmericaUniBestYoubaidaeasyTestseriesQuick Pb Cd HgHandheld water quality heavy metal analyzer