Shanghai Zhonglian Fa Environmental Protection Development Co., Ltd
Home>Products>UniBest Portable MetalSafe handheld trace heavy metal analyzer from the United States
Product Groups
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
  • Address
    228 Meiyuan Road, Enterprise Plaza, Jing'an District, Shanghai
Contact Now
UniBest Portable MetalSafe handheld trace heavy metal analyzer from the United States
UniBest Portable MetalSafe handheld trace heavy metal analyzer from the United States
Product details


Brief introduction

Anodic stripping voltammetry, with its extremely low cost and high sensitivity, is currently replacing traditional atomic absorption methods and widely used in environmental emergency monitoring, tap water detection, electroplating and surface treatment industry wastewater detection, food, pharmaceutical, hospital wastewater monitoring, and other fields in Europe and America. AmericaEPAWhen institutions have listed it as a standard testing method, keep track of the location, such asEPA7063reach7472wait.

2、 Electrode principle

cause100A nanobelt electrode is composed of nanobelt electrodes, and the signals generated by each small electrode are accumulated to enhance the total signal, thereby increasing sensitivity and reducing the lower detection range. No other commercial electrode can be so fast, sensitive, and accurate. The combination of nanobelt electrode and square wave anodic stripping voltammetry can accurately measure Faraday current by subtracting the background current from the measured current, effectively improving the signal-to-noise ratio. This signal processing method further enhances the sensitivity of the instrument, with fast electrode scanning speed and up to10bend over/Seconds, no need for deoxygenation during detection.3、 Main features

1 Testing time:30-120Seconds, the preparation time before detection only takes a few minutes

2 At least detectable heavy metal ions6Species, including: arsenic (including arsenic)With arsenicV)Cadmium, copper, mercury, lead, zinc, and can also be extended to detect chromium, manganese, nickel, antimony, tinthalliumIroncobaltclass

3 Can support users to develop more detection methods for heavy metal ions, built-in10Multiple programmable menus, free upgrade program provided by Chinese agents within two years of purchase

4 Detection accuracy:±3-5%0100ppb

5 Accuracy:1ppb

6 resolving power:0.1ppb

7 According to the different types of heavy metal ions measured, three types of three in one electrodes are provided as alternatives (nanobelt iridium working electrode, nanobelt carbon working electrode, glassy carbon working electrode)

8 Handheld touch screen intelligent software operation, data processing, and display terminal

9 The three in one electrode has stable performance and is easy to maintain and clean

10Nanobelt electrodes form electrode bundles, improving sensitivity20times

11Remove illegal pulling interference current without the need for oxygen removal during detection

12Reusable times of electroplating solution:≥100order

13The electrode scanning speed is fast and can reach10bend over/second

14Power supply: portable rechargeable battery

15Data storage capacity: up to storage capacity1,000,000Measurement data

4、 Product Features

1 Detection spectrum width:MetalSafeThe portable heavy metal analyzer can detect heavy metals including arsenic (arsenic) through software settingsarsenicV)Cadmium, copper, mercury, lead, zinc, and can also be extended to detect chromium, manganese, nickel, tin, thallium, iron, cobalt, antimonyGold and bismuthPlasma heavy metals. This instrument has superior scalability and supports the development of more heavy metal detection methods independently.

2 Nanobelt technology has high precision and sensitivity.UniBestThe company's proprietary nanobelt electrode is actually made up of100Composed of individual electrodes, it can provide unparalleled speed and sensitivity.

3 The three in one electrode has stable performance and is easy to maintain and clean. Each small electrode occupies a small surface, and the scanning speed reaches10bend over/Seconds make the measurement speed very fast.

4 The system software is equipped with standard addition method, standard curve method, automatic calculation of dilution factor, automatic saving of all data for future query, and report function.

5 Electroplating solution can be reused100Secondly, it has less pollution discharge and lower instrument usage costs.

6 Strong anti-interference ability: The first and second types of metals in the periodic table (such as sodium, potassium, etc.) do not interfere with the detection. Improve the accuracy of the instrument.

7 Support for self-developed extended detection methods: In addition to the metal ion detection methods currently provided by manufacturers, the device itself supports users to develop dozens of heavy metal ion detection methods according to their needs.

8 Low operating cost: The power consumption cost of the instrument is very low when it is turned on, and the amount of reagents and consumables such as standard solutions is minimal.

9 Easy to use: light weight, small size, easy to carry. It can be used for laboratory testing as well as field testing.

10Field use: Rechargeable batteries ensure sustainable power supply, handheld touch screen intelligent software operation and data processing, and display terminals control the measurement program of the instrument and display and output readings.

11Working hours: The handheld touch screen intelligent software operation, data processing, and display terminal of the instrument achieve low power consumption, have ultra long battery life, and can work continuously for up to6to8Hours, standby time can reach200Hour.

12Additional features: The instrument operating system can be optionally equipped with a global positioning system to provide real-time location information and a built-in wireless network card for remote data transmission. Facilitate leaders to timely understand the on-site situation for faster decision-making and command.

13Communication interface:RS-232reachUSBInterface.

14Safety guarantee: The reaction design is safe, and operators can avoid contact with toxic substances such as mercury when using it. The electrode bismuth film method can be used instead of the electrode mercury film method, which can effectively avoid environmental pollution during the detection process.

15Heavy metal detection in liquids: The operation is very convenient,MetalSafeWidely used in environmental emergency monitoringIn the fields of measurement, drinking water sources, tap water, surface water, water for food and beverage (health products), and biopharmaceuticals.

16Heavy metal detection in solids: heavy metal ions need to be extracted from the sample to be tested first,MetalSafePortable trace heavy metal analyzers are widely used for the determination of heavy metal content in solid substances such as soil, food, and solid waste.

5、 Technical parameters

Technical indicators of nanobelt electrode

electrode type

Three in one nanoribbon iridium electrode

Three in one nanobelt carbon electrode

Three in one glassy carbon electrode

Measurement elements

Cadmium, copper, lead, zinc

arsenicAs3+As5+Total arsenic, mercury

Chromium, manganese, nickel, antimony, tin, thallium

measuring range

0. 1ppbto100ppm

0.1ppbto100ppm

0.1ppbto100ppm

Lower detection limit

Cadmium:≥0.1ppb

Copper:≥0.1ppb

Lead:≥0.1ppb

Zinc:≥0.1ppb

Arsenic:0.1ppb

Mercury:0.1ppb

Chromium:0.1 ppb

Manganese:0.1ppb

Nickel:0.1 ppb

Antimony:0.1ppb

Tin:0.1 ppb

Thallium:0.1ppb

Accuracy andICP-MSperhapsAACompared to errors less than

<5%

<5%

<5%

Chemical Reagents

Cadmium, copper, lead, zinc standard solution(20ppm)And supporting reagents

Arsenic and mercury standard solutions(20ppm

And supporting reagents

Standard solutions of chromium, manganese, nickel, antimony, tin, and thallium 20ppm)And supporting reagents

Other consumables

Disposable cups of deionized water (or distilled water)(30-50mL

Electrode polishing pad

Deionized water (or distilled water)

Disposable cup(30-50mL

Electrode polishing pad

Deionized water (or distilled water)

Disposable cup(30-50mL

Electrode polishing pad

Upper limit resolution

0.1 ppb

check the accuracy

±5% (@100 ppb)

Instrument weight

1. 3kg

Operation range

Temperature range(0-40°C), humidity range(20-90%

Operating system requirements

Microsoft Windowssystem

Data file format

outputEXCELperhapsMATLABWaiting format

Suitcase size

500x410x190mm

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!