Turb 555IR Laboratory Turbidity Analyzer (WTW GmbH, Germany)Product Introduction:
The Turb 555IR laboratory turbidity meter has a very wide testing range, from 0.0001 to 10000 NTU, and is used in applications ranging from ultrapure water, drinking water, soft drinks to wastewater. The measurement system comes with 4 sensors, which can not only test 90 ° scattered light and 180 ° transmitted light, but also achieve ratio testing to improve the resistance to stray light and chromaticity. The testing unit can choose EBC, which can be used in the beer industry. The comprehensive AQA function ensures testing accuracy and stability, such as allowing users to set calibration intervals, password protection for calibration, timed calibration, and access to files required for quality assurance.
Optional turbidity flow tank, capable of continuous flow measurement, with pressure up to 4 bar.
The instrument is equipped with backlight display, making reading convenient and simple. The testing resolution is high, and users can choose the appropriate resolution. The instrument adopts a menu based operation, which is very simple to operate.
Standard configuration
Complete supply, including 4 AMCO standard solutions, can calibrate 4000NTU. For applications measuring up to 10000 NTU, larger standard solutions can also be selected. Due to precision manufacturing, AMCO standard solution is more stable and accurate in the long term than Formazine standard solution
Turb 555IR Laboratory Turbidity Analyzer (WTW GmbH, Germany)Technical parameters:
model | Turb 555 IR | |
measuring principle | 90°Scattered light turbidity method Ratio testing method 180°Transmittance turbidity method |
|
Lighting | infraredLED | |
measure range |
NTU | 0 ten thousand |
FNU | 0 ten thousand | |
EBC | 0 two thousand four hundred and fifty | |
Nephelos | – | |
FAU | 0 ten thousand | |
resolution | 0.0001 NTU from 0.0001 ... 9.9999 NTU 0.001 NTU from 10.000 ... 99.999 NTU 0.01 NTU from 100.00 ... 999.99 NTU 0.1 NTU from 1000.0 ... 9999.9 NTU |
|
accuracy | 0 1000 NTU: ±2%Measurement value or±0.01 NTU 1000 ... 4000 NTU: ±5%Measurement value 4000 ... 10000 NTU: ±10%Measurement value |
|
repeatability | ±1%Measurement value or±0.01 NTU | |
correct | Automatic calibration from 1-5 o'clock | |
reaction time | < 6second | |
Colorimetric tube | 28 x 70 mmCircular colorimetric tube, 25 mlSample Volume | |
AQAfunction | Calibration interval monitoring Generate calibration records after calibration is completed Set and calibrate with password protection Timing controlleddata transfer |
|
operate temperature | 0 50 °C | |
power supply | 100 - 240 VAC ±10% / 47 - 63 Hz |
3、 Selection
Turb 555IR | High performance red light laboratory turbidity meter, containing calibration solution (0.02-10.0-100-1750 NTU)and3An empty test tube, optional: with a pressure resistance of1barContinuous measurement slotD-Turb(600605) | 600210 |