ZY-DLSR-EX-4 thermocouple/millivolt single/dual channel input safety barrierDetailed information:

The single channel thermocouple or millivolt signal from the hazardous area is isolated and transmitted to output single/dual current or voltage signals to the safe area. The instrument has automatic compensation for cold end temperature and can be connected to the safe area through a configured communication interface for serial communication networking. It is an intelligent safety barrier product with online fault self diagnosis function. Users can also set the input signal type and output range of this product through a dedicated handheld Chinese programmer.

Explosion proof mark:
[Exia]ⅡC

Number of safety barrier channels:
Single/Dual Channel

Transmission accuracy:
± 0.2% F.S (excluding cold end compensation accuracy)


Dangerous area allows input signals:
Thermocouple: K、E、S、B、J、T、R、N
Millivolts: 0~20mV, 0~75mV, 0~100mV The signal type and range are determined at the time of ordering and can also be programmed by oneself.

Output signal to the safe zone:
DC current: 4~20mA
Note: Signal types such as 0~10mA, 0~20mA, 0~5V, 1~5V, 0~10V, etc. are required. Please confirm when ordering, or you can program them yourself.

The output of the safety barrier relay is:
Response time: less than 20mS
Allow (resistive) load: AC125V 0.5A,DC24V 1A
Output load capacity:
4-20mA:0~300Ω; 0-10mA:0~600Ω
0(1)-5V:≥500KΩ; 0-10V:≥ 1MΩ
(Please specify when placing an order if higher load capacity is required)

Certification parameters (between terminals 1 and 2) of the National Explosion proof Electrical Product Quality Supervision and Inspection Center (CQSTI):
Um =250VAC/DC,Uo=11.2V,Io=17.3mA,Po=48.5mW
ⅡC : Co=1.28μF,Lo=82.8mH,
ⅡB : Co=8.82μF,Lo=248.4mH,
ⅡA : Co=37.8μF,Lo=662.4mH,

Cold end compensation accuracy: ± 1 ℃ (preheating for 30 minutes)

ZY-DLSR-EX-4 safety barrierpower waste:
1.2W (24 power supply, single 20mA output)
1.8W (24V power supply, dual 20mA output)

ZY-DLSR-EX-4 safety barrierCalibration:
This product adopts intelligent digital design, which can ensure long-term accuracy within the specified range. If calibration is required, please choose the dedicated product provided by our company
Operate with a handheld Chinese programmer.

Selection method:

model
explain
ZY-DLSR-EX-4
LCD detection terminal safety type
Thermocouple input, single/dual output
Channel
Default is single channel
D
Dual input channel
First output
1
4-20mA
2
1-5V
3
0-10mA
4
0-5V
5
0-10V
6
0-20mA
7
1: 1 millivolt signal output
second output
Default no second output
1
4-20mA
2
1-5V
3
0-10mA
4
0-5V
5
0-10V
6
0-20mA
Communication and alarm functions (if this option is selected, there will be no second output function)
Default is no communication function
T1
485 communication (single output only)
T2
232 communication (single output only)
A1
Alarm relay output (single output only)
A2
Alarm relay output (dual output)


ZY-DLSR-EX-4 safety barrierexplain:
1. Single channel products can have up to two outputs; Dual channel products can only correspond to one output per channel.
2. Communication or alarm products only have a single input and can only output up to one analog signal (current or voltage)
3. Products containing alarms need to indicate whether they are in the upper or lower limit alarm mode (or modified through our company's dedicated programmer), and whether the alarm contacts are in the normally open or normally closed state.
When selecting the dual alarm relay output, there is no analog signal (current or voltage) output function.
5. If different input signals are required for dual channel products, please contact our company for special ordering
6. Please specify the input type and corresponding output range of the thermocouple when placing an order. If the user needs to program it themselves, please choose the dedicated handheld programmer provided by our company for operation.
7. When selecting millivolt output, there is a 1:1 linear proportional relationship between linear millivolt input and output; When the input signal is a thermocouple (non-linear), the millivolt output corresponds to the millivolt charge of the input thermocouple (the same non-linear signal), and does not include temperature compensation.
The wiring diagram of the safety barrier:
Width x Height x Depth (18 x 100 x 115mm)
点击查看大图片

sellafterclothesaffairbearNuo
Through the various products sold by our company, we guarantee to provide sales of products and spare parts at the same price within two years,And provide corresponding technical support free of charge according to the requirements of the demander.
Our company is responsible for free maintenance and technical support, as well as skill training for the customer's employees, in case of any quality issues with the products provided within one year (excluding vulnerable parts or accessories).
Due to quality issues with the products provided by our company, it has been verified by our technical department,The company will dispatch professional technical personnel to the site to handle the problem to customer satisfaction (domestic)72Hours, Jiangsu, Zhejiang, Shanghai48Arrive at the scene within hours),Technical support is available6Respond within hours.

If you are correctZY-DLSR-EX-4 thermocouple/millivolt single/dual channel input safety barrierIf you are interested and would like to learn more detailed product information, please fill out the following form to directly contact the manufacturer:
Comments Box
Products of interest: *
Your organization: *
Your name: *
contact number: *
Detailed address:
Common email:
Any of your requests, opinions, or suggestions:
*
Verification Code: * Please enter the result (Arabic numerals), for example: Three plus four=7




Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!