The Taishuang TS7X series grating spectrophotometer is a grating spectrophotometer that 3nh Company has spent 3 years carefully designing and fully owns independent intellectual property rights. The instrument uses a 1000 line precision scintillation grating as the spectral element, a silicon photovoltaic array with a relatively large photosensitive area as the detector, and a high lifetime full spectrum LED as the light source. The optical resolution is less than 10nm in the visible light range.
Under the D8 geometric optical illumination conditions recommended by CIE, the Taishuang TS7700 spectrophotometer can accurately measure the SCI and SCE reflectance data of samples/fluorescent samples. It can accurately measure and express various color difference formulas and color indices in multiple color spaces. With the help of the Tai Shuang TS7700 spectrophotometer, accurate color transfer can be easily achieved, and it can also be used as a detection device for accurate color matching systems.
The Taishuang TS7700 spectrophotometer is also widely used in color difference quality control of various products. The Taishuang TS7700 is equipped with high-end color management software, which can be connected to a computer for further functional expansion. The instrument has stable performance, accurate color measurement, and powerful functions. It is widely used in industries such as plastic electronics, paint and coatings, textile printing and dyeing, printed paper products, automotive, medical, cosmetics, and food, as well as in scientific research institutions and laboratory fields.
Characteristics of Taishuang TS7700 spectrophotometer
Technical parameters of Taishuang TS7700 spectrophotometer
PRODUCT MODEL | Tai Shuang TS7700 |
Illumination | D/8 (diffuse illumination, receiving in 8 ° direction); SCI/SCE measurement; Including UV/exclusion UV measurement; Complies with the standard CIE No.15, GB/T 3978,GB 2893,GB/T 18833,ISO7724-1,ASTM E1164,DIN5033 Teil7 |
characteristic | Dual testing caliber, used for accurate color analysis and transmission in the laboratory; Used for accurate color measurement and quality control in industries such as plastic electronics, paint and ink, textile and clothing printing and dyeing, printing, ceramics, etc; Can be used for measuring fluorescent samples. |
Integral sphere size | Φ40mm |
lighting source | Combination full spectrum LED light source, UV light source |
Spectral method | Planar grating spectroscopy |
a sensor | Silicon photodiode array (double row 40 groups) |
Measuring wavelength range | 400~700nm |
wavelength interval | 10nm |
Half bandwidth | 10nm |
Reflectance measurement range | 0~200% |
measuring aperture | Dual caliber: MAV:Φ8mm/Φ10mm; SAV:Φ4mm/Φ5mm |
Light containing method | Simultaneously testing SCI/SCE |
color space | CIE LAB,XYZ,Yxy,LCh,CIE LUV,s-RGB,HunterLab,βxy,DIN Lab99 Munsell(C/2) |
colour-difference formula | ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00, DINΔE99,ΔE(Hunter) |
Other chromaticity indicators | WI(ASTM E313,CIE/ISO,AATCC,Hunter), YI(ASTM D1925,ASTM 313), The same color spectral index Mt, Stain fastness, color fastness, strength, coverage 8 degrees glossiness, 555 color tone classification |
Observer's perspective | 2°/10° |
Observing light source | D65,A,C,D50,D55,D75,F1,F2(CWF),F3,F4,F5,F6,F7(DLF),F8,F9,F10(TPL5),F11(TL84),F12(TL83/U30) |
display | Spectral chart/data, sample chromaticity values, color difference values/graph, qualified/unqualified results, color simulation, color bias |
Time | About 1.5 seconds (testing SCI/SCE simultaneously takes about 3.2 seconds) |
repeatability | Spectral reflectance: MAV/SCI, Standard deviation within 0.08% (400~700nm: within 0.18%): Chromaticity value: MAV/SCI, Δ E * ab within 0.03 (after preheating correction, measure the average value of the whiteboard 30 times at intervals of 5 seconds) |
Inter station difference | MAV/SCI, Δ E * ab within 0.15 (average value measured on 12 color plates of BCRA series II) |
Measurement method | Single measurement, average measurement (2-99 times) |
locate mode | Display screen camera framing positioning, stabilizing film positioning |
size | Length X width X height=129X76X217mm |
weight | About 600g |
battery level | Lithium battery, 6000 times within 8 hours |
Lighting source lifespan | More than 3 million measurements in 5 years |
display | TFT True Color 3.5inch, Capacitive Touch Screen |
interface | USB, Bluetooth ® four point two |
Store data | 1000 standard samples and 30000 test samples (one data can include SCI/SCE at the same time) |
language | Simplified Chinese, English, traditional Chinese |
Operating temperature range | 0~40 ℃, 0~85% RH (no condensation), altitude: below 2000m |
Storage Temperature Range | -20~50 ℃, 0~85% RH (no condensation) |
Standard accessory | Power adapter, data cable, manual, quality management software (official website download), black and white calibration box, protective cover, wristband, Ø 8mm platform caliber, Ø 8mm pointed caliber, Ø 4mm platform caliber, Ø 4mm pointed caliber |
Optional Accessories | Micro printer, powder testing box |
Note: | Technical parameters are for reference only, subject to actual sales of products |