Conner (Shanghai) Environmental Technology Co., Ltd
Home>Products>TSI Multi Parameter Ventilation Meter 9555 Series from the United States
TSI Multi Parameter Ventilation Meter 9555 Series from the United States
Introduction to TSI Multi Parameter Ventilation Meter Instrument in the United States: The 9555 series is a portable and handheld multifunctional vent
Product details

TSI Multi Parameter Ventilation Meter in the United StatesInstrument Introduction:
The 9555 series is a portable and handheld multifunctional ventilation testing instrument. These instruments can be equipped with differential pressure sensors and multiple wide range, plug-in probes. Users can choose the most suitable probe from a variety of probes with different functions according to their actual testing needs. Simply plug in the probe to achieve multiple tests. These probes can measure wind speed, temperature, relative humidity, CO, and CO2. The parameters that can be calculated include air volume, heat flux, turbulence, wet bulb temperature, and dew point temperature.


TSI Multi Parameter Ventilation Meter in the United StatesMain features:
-High level precision, especially at low wind speeds;
-Zui can display 5 test parameters simultaneously;
-Optional "smart" plug-in probes, including CO2 and impeller probes;
-Large screen display;
-Manual or continuous data recording function;
-Includes TRAKPROTM and LogDat2TM software;
-Name of user-defined test data group;
-Supports Bluetooth ®) printer;
-Quick calibration and repair service - simply return the probe.


Technical parameters:
9555, 9555-A, 9555-P, and 9555-X models

Wind speed (960 and 962 TA probes)
Range 0~9999 ft/min (0~50m/s)
Accuracy of ± 3% of 1&2 readings, or ± 3ft/min (± 0.015m/s) (whichever is greater)
Resolution 1 ft/min (0.01m/s)

Wind speed (applicable to 9555, 9555-A, 9555-P probes)
Range 3 250~15500 ft/min (1.27~78.7m/s)
Accuracy 4 at 2000 ft/min (10.16 m/s), ± 3%
Resolution 1 ft/min (0.01m/s)

Wind speed (955 type impeller probe)
Range 50~6000 ft/min (0.25~30m/s)
Accuracy reading of ± 1%, or ± 4ft/min (± 0.02m/s)
Resolution 1 ft/min (0.01m/s)

Duct size
Size 1-250 inches, The increment is 0.1 inches (1~635cm, increment of 0.1cm)

Volume flow rate
The actual range is a function of wind speed, pressure, duct size, and K coefficient

Temperature (964 and 966 TA probes, 980 and 982 IAQ probes)
Range: 14-140 ℉ (-10-60 ℃)
Accuracy 5 ± 0.5 ℉ (0.3 ℃)
Resolution 0.1 ℉ (0.1 ℃)

Temperature (960 and 962 TA probes)
Range 0-200 ℉ (-18-93 ℃)
Accuracy 5 ± 0.5 ℉ (0.3 ℃)
Resolution 0.1 ℉ (0.1 ℃)

Temperature (995 impeller probe)
Range 32-140 ℉ (0-60 ℃)
Accuracy 5 ± 2.0 ℉ (0.1 ℃)
Resolution 1.0 ℉ (0.1 ℃)

Relative humidity (Type 964 and 966 TA probes, Type 980 and 982 IAQ probes)
Range 0-95% RH
Accuracy 6 ± 3% RH
Resolution 0.1% RH

Carbon monoxide (982 IAQ probe with CO function)
Range 0-500 ppm
Accuracy of 7 readings ± 3%, or ± 3ppm (whichever is greater)
Resolution 0.1 ppm

Carbon dioxide (980 and 982 IAQ probes)
Range 0-5000 ppm
Accuracy: ± 3% of the reading, or ± 50ppm, whichever is greater
Resolution 0.1 ppm

Static pressure/differential pressure (applicable to 9555, 9555-A, 9555-P models)
Range 9-15~+15H2O (-28.0~+28.0 mmHg, -3735~+3735 Pa)
± 1% ± 0.005 inH2O (± 0.01 mmHg, ±1Pa)
Resolution 0.001 in. H2O (1 Pa, 0.01mmHg)

Atmospheric pressure
Range 2.036-36.648 in. Hg (517.15~930.87 mmHg)
2% accuracy reading

Temperature range of the instrument
Operating temperature (host) 40-113 ℉ (5-45 ℃)
Storage temperature -4~140 ℉ (-20~60 ℃)

Data storage capacity of 26500 data and 100 data sets

Data collection interval of 1 second to 1 hour

User defined time constant

Instrument size 3.8 in. x 8.3 in. x 2.1 in. (9.7 cm x 21.1 cm x 5.3 cm)

Instrument weight (with battery) 0.8lbs (0.36kg)

Instrument probe size
Probe length 40 in. (101.6 cm)
Probe top diameter 0.28 in. (7.0 mm)
Probe base diameter 0.51 in. (13.0 mm)

Bendable probe size
The length of the bent part is 7.8 in. (19.7 cm)

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!