Static grounding alarm/fixed static grounding alarm
Static grounding alarm is a standardized product for anti-static in oil loading and unloading situations. It can not only guide the static electricity
Product details

Detailed information on DS/SA-MA static grounding alarm/fixed static grounding alarm:

Static grounding alarm/fixed static grounding alarmProduct Introduction:

Static grounding alarm is a standardized product for anti-static in oil loading and unloading situations. It can not only guide the static electricity generated during liquid transportation to the ground, but also automatically detect the grounding status throughout the process. When the grounding is poor or disconnected, sound an alarm to ensure the safety of production operations.

On the basis of DS/SA-MA, DS/SA-MA products have added automatic wire collection function, greatly improving the convenience of equipment operation.

 Static grounding alarm/fixed static grounding alarmUsage scenario:

1. Gas station unloading port;

2. Loading and unloading locations at gas stations;

3. Unloading sites for liquid chemicals such as chemical plants;

4. Others such as paint factories, pharmaceutical factories, etc

5. If applied to oil tanker terminals, please click to go to the dedicated DS/SA-MC type for oil tankers.
 Technical parameters:
1. Explosion proof grade: ExiaIICT6
2. Detecting resistance: < 60Ω
3. Alarm volume:> 90dB (30cm straight-line distance measurement)
4. Dimensions: 260mm × 260mm × 150mm
5. Standard wire length: The clamp end wire is 7 meters long, and the grounding end wire is 3 meters long.

 Reference national standards:

1. GB50156-2002 "Design and Construction Specification for Automobile Gas Filling Stations I":
Article 10.3.2 stipulates that the unloading sites for gasoline tank trucks and liquefied petroleum gas tank trucks at refueling stations should be equipped with lightning protection grounding devices for tank truck unloading, and static grounding devices capable of detecting jumper wires and monitoring the status of grounding devices should be installed.
Article 10.3.4 stipulates that the grounding resistance of the anti-static grounding device should not exceed 100 ohms.
2. GB50074-2002 "Design Code for Petroleum Storage":
Article 14.3.11 stipulates that anti-static grounding devices used for cross connections in oil loading and unloading areas should use anti-static grounding instruments that can detect grounding conditions.
Article 14.3.15 stipulates that the grounding resistance of the anti-static grounding device should not exceed 100 ohms.

Quality Service Commitment:1.The warranty period is 18 months, with lifetime free maintenance.2.During the warranty period, except for human factors, we will repair or replace any defects or malfunctions caused by improper instrument design, materials, or processes free of charge3.Upon receiving notification from the user that the provided instrument has malfunctioned, respond within ten minutes.4.Ensure timely provision of necessary spare parts and consumables to users at the most favorable prices