Multidimensional gas chromatograph (gas analysis system)
Multidimensional gas chromatograph (gas analysis system)
Product details
Multidimensional gas chromatograph (gas analysis system)
Scope of application:
Coke oven gas, artificial gas, converter gas, blast furnace gas, natural gas, refinery gas, water gas, semi water gas, liquefied petroleum gas
Introduction to Gas Analysis:
The gas analysis system uses automatic ten way valve automatic injection cutting and blowback technology to solve the full analysis of gases such as hydrogen, oxygen, nitrogen, carbon monoxide, carbon dioxide (ppm level CO and CO2 can be analyzed by installing a converter), methane, ethane, ethylene, acetylene, propane, cyclopropane, propylene, propyne, n-butane, isobutane, n-butene, isobutene, isobutene, maleic, isobutene, isopentane, n-pentane, 1,3-butadiene, n-hexane, etc. in one injection.
Execution standards:
GB/T 10410-2008 Gas Chromatography Analysis Method for Constant Components of Artificial Gas and Liquefied Petroleum Gas
GB/T 12208-2008 Determination of Composition and Impurity Content of Artificial Gas
GB/T 11062-1998 "Calculation Method for Heating Value, Density, Average Density, and Wopo Index of Natural Gas"
SH/T 0230-92 "Determination of Composition of Liquefied Petroleum Gas (Chromatography Method)"
GB/T 13610-2003 "Composition Analysis of Natural Gas - Gas Chromatography Method"
GB/T 12206-2006 "Determination of Heating Value and Relative Density of Urban Gas"
GB 10410.1-89 "Gas Chromatography Analysis Method for Components of Artificial Gas"
GB 10410.2-89 "Gas chromatographic analysis of constant components in natural gas"
GB 10410.3-89 "Gas Chromatography Analysis of Liquefied Petroleum Gas Components"
Performance characteristics:
Based on the new generation high-performance and high stability GC-7900 gas chromatograph, it operates reliably and stably.
◆ Wide applicability, can be used for various types of gas analysis.
Adopting a multidimensional chromatography system, up to 6 injection or cutting valves can be driven, and n packed columns or capillary columns can be installed as needed.
Injection method: Valves can be connected in series for injection or injected separately, which can achieve split injection without splitting.
Detector: thermal conductivity detector, hydrogen flame detector, flame photometric detector, and installation of conversion furnace. It can be used in series or separately.
◆ Equipped with 4/8 liter aluminum bottles for multi-component standard mixed gas or single component gas.
◆ Dual channel chromatography workstation, supporting Windows XP operating system, allows for free storage, data processing, and report printing of chromatographic analysis spectra.
◆ It can be equipped with a dedicated chromatography workstation for natural gas analysis, which can calculate technical parameters such as calorific value, white number, relative density, compressibility factor, etc. of natural gas.
◆ It can achieve online automatic analysis, and through the installation of pipeline instruments, it can automatically sample on a periodic basis. It can monitor and calibrate the process sample gas continuously without the need for manual calibration. The probe of the pipeline can be manually sampled and tested in places where it has not been laid, which is flexible and reliable.
Instrument technical specifications:
1. Hydrogen flame ionization detector (FID):
Cylindrical collection electrode structure design, quartz nozzle, extremely responsive
Detection limit: ≤ 8 × 10-12G/s (n-hexadecane/isooctane)
Baseline noise: ≤ 2 × 10-13A
Baseline drift: ≤ 2 × 10-12A/30min
Linear: ≥ 106
Stable time: Ten minutes
2. Thermal conductivity detector (TCD):
Adopting a semi diffusive structure
The power supply adopts constant current control mode
Sensitivity: ≥ 3000mV · ml/mg, high sensitivity ≥ 8000mV · ml/mg
Baseline noise: ≤ 10 μ V.
Baseline drift: ≤ 100 μ V/30min.
Linear: ≥ 104
3. Large screen LCD display:
Clearly display the set values, measured values, and protection values of each temperature channel
Real time display of instrument status
Touch sensitive keyboard, menu based operation
4. Temperature control indicators:
Column box: 5 ℃~399 ℃ at room temperature with an accuracy of ± 0.1 ℃
Sample injector: 5 ℃~399 ℃ at room temperature with an accuracy of ± 0.1 ℃
Detector: 5 ℃~399 ℃ at room temperature with an accuracy of ± 0.1 ℃
5. Quantitative repeatability RSD ≤ 3%
6. Qualitative repeatability RSD ≤ 1%
7. Detection range: 0.01% -99.99%
System composition:
Scope of application:
Coke oven gas, artificial gas, converter gas, blast furnace gas, natural gas, refinery gas, water gas, semi water gas, liquefied petroleum gas
Introduction to Gas Analysis:
The gas analysis system uses automatic ten way valve automatic injection cutting and blowback technology to solve the full analysis of gases such as hydrogen, oxygen, nitrogen, carbon monoxide, carbon dioxide (ppm level CO and CO2 can be analyzed by installing a converter), methane, ethane, ethylene, acetylene, propane, cyclopropane, propylene, propyne, n-butane, isobutane, n-butene, isobutene, isobutene, maleic, isobutene, isopentane, n-pentane, 1,3-butadiene, n-hexane, etc. in one injection.
Execution standards:
GB/T 10410-2008 Gas Chromatography Analysis Method for Constant Components of Artificial Gas and Liquefied Petroleum Gas
GB/T 12208-2008 Determination of Composition and Impurity Content of Artificial Gas
GB/T 11062-1998 "Calculation Method for Heating Value, Density, Average Density, and Wopo Index of Natural Gas"
SH/T 0230-92 "Determination of Composition of Liquefied Petroleum Gas (Chromatography Method)"
GB/T 13610-2003 "Composition Analysis of Natural Gas - Gas Chromatography Method"
GB/T 12206-2006 "Determination of Heating Value and Relative Density of Urban Gas"
GB 10410.1-89 "Gas Chromatography Analysis Method for Components of Artificial Gas"
GB 10410.2-89 "Gas chromatographic analysis of constant components in natural gas"
GB 10410.3-89 "Gas Chromatography Analysis of Liquefied Petroleum Gas Components"
Performance characteristics:
Based on the new generation high-performance and high stability GC-7900 gas chromatograph, it operates reliably and stably.
◆ Wide applicability, can be used for various types of gas analysis.
Adopting a multidimensional chromatography system, up to 6 injection or cutting valves can be driven, and n packed columns or capillary columns can be installed as needed.
Injection method: Valves can be connected in series for injection or injected separately, which can achieve split injection without splitting.
Detector: thermal conductivity detector, hydrogen flame detector, flame photometric detector, and installation of conversion furnace. It can be used in series or separately.
◆ Equipped with 4/8 liter aluminum bottles for multi-component standard mixed gas or single component gas.
◆ Dual channel chromatography workstation, supporting Windows XP operating system, allows for free storage, data processing, and report printing of chromatographic analysis spectra.
◆ It can be equipped with a dedicated chromatography workstation for natural gas analysis, which can calculate technical parameters such as calorific value, white number, relative density, compressibility factor, etc. of natural gas.
◆ It can achieve online automatic analysis, and through the installation of pipeline instruments, it can automatically sample on a periodic basis. It can monitor and calibrate the process sample gas continuously without the need for manual calibration. The probe of the pipeline can be manually sampled and tested in places where it has not been laid, which is flexible and reliable.
Instrument technical specifications:
1. Hydrogen flame ionization detector (FID):
Cylindrical collection electrode structure design, quartz nozzle, extremely responsive
Detection limit: ≤ 8 × 10-12G/s (n-hexadecane/isooctane)
Baseline noise: ≤ 2 × 10-13A
Baseline drift: ≤ 2 × 10-12A/30min
Linear: ≥ 106
Stable time: Ten minutes
2. Thermal conductivity detector (TCD):
Adopting a semi diffusive structure
The power supply adopts constant current control mode
Sensitivity: ≥ 3000mV · ml/mg, high sensitivity ≥ 8000mV · ml/mg
Baseline noise: ≤ 10 μ V.
Baseline drift: ≤ 100 μ V/30min.
Linear: ≥ 104
3. Large screen LCD display:
Clearly display the set values, measured values, and protection values of each temperature channel
Real time display of instrument status
Touch sensitive keyboard, menu based operation
4. Temperature control indicators:
Column box: 5 ℃~399 ℃ at room temperature with an accuracy of ± 0.1 ℃
Sample injector: 5 ℃~399 ℃ at room temperature with an accuracy of ± 0.1 ℃
Detector: 5 ℃~399 ℃ at room temperature with an accuracy of ± 0.1 ℃
5. Quantitative repeatability RSD ≤ 3%
6. Qualitative repeatability RSD ≤ 1%
7. Detection range: 0.01% -99.99%
System composition:
name | Model and configuration | origin |
gas chromatograph | GC-7900/7890/9860, TCD detector, FID detector | Shanghai |
sampling device | Pneumatic valve automatic sampling | Shanghai |
Cutting method | Pneumatic valve automatic cutting | Shanghai |
chromatographic column | Customize according to specific customer requirements | Shanghai |
data processing system (Choose one) |
Dual channel data processing system (instrument signal with two outputs) | Shanghai |
Gas dedicated workstation | Shanghai | |
Carrier gas for chromatography (Customized according to requirements) |
Nitrogen generator 300ml/min, 500ml/min | Shanghai |
Hydrogen generator 300ml/min, 500ml/min | Shanghai | |
Nitrogen purity 99.999% | Shanghai | |
Argon purity 99.999% | Shanghai | |
Helium purity 99.999% | Shanghai | |
Standard gas | 4/8 liter aluminum bottle with pressure reducing valve (customized according to customer needs) | Shanghai |
Starter Kits | Shanghai | |
Computer, printer | self-provide |