The Mettler HX204 halogen moisture analyzer has the best measurement performance. The Mettler HX204 halogen moisture analyzer provides accurate and fast results. The Mettler HX204 halogen moisture analyzer can be cleaned in 30 seconds. The surface under the scale of the Mettler HX204 halogen moisture analyzer is flat and completely sealed, making it easy to clean quickly.
readability | 0.01% / 0.001% |
Repeatability (SD) (2 g sample) | 0.05% |
Repeatability (SD) (10 g sample) | 0.01% |
display mode | % MC, % DC, % ATRO MC/ DC, g, g/kg MC, g/kg DC |
Range of measurement | 200g |
readability | 1mg/0.1mg |
temperature range | 40-230°C |
Open the lid | Motorized |
Weighing unit testing | Indication error of any quality point, default 100g |
Heating unit testing | 2-point temperature calibration for calibration and arbitrary temperature settings |
Fully Automatic Calibration Technology (FACT) | correct |
Calibration of weighing unit | Indication error of any quality point, default 100g |
Heating unit calibration | 2-point temperature calibration for arbitrary temperature definition (default: 100/160 ° C) |
temperature program | Standard, gentle, fast, and tiered |
Method storage | 300 |
Control Chart | correct |
Drying curve | correct |
Qualified/unqualified judgment | correct |
Horizontal control | LevelControl system with warning function |
Best measurement performance
Hanging scale pan
The innovative suspended scale design of the halogen moisture analyzer avoids the influence of the heat from the sample chamber on the scale, and improves the measurement results by eliminating the negative thermal effects of the symmetrical unit. The high-performance MonoBloc weighing unit of the halogen moisture analyzer can provide maximum range and optimal resolution (200g, 0.1mg, (HX204 model)), and the halogen moisture analyzer can meet the most demanding tasks.
Accurate and fast results
Second generation halogen lamp heating technology
The halogen moisture analyzer surpasses the best quality. The second-generation halogen heating technology of the halogen moisture analyzer minimizes the amount of hot material and enhances performance by shortening the heating/cooling cycle and precise temperature control. The halogen moisture analyzer uses a cold instrument for the first measurement, and the accuracy of subsequent measurements using a hot instrument is the same.
Clean in 30 seconds
The halogen moisture analyzer has a smooth and sealed surface
The weighing unit is located behind the instrument, and spilled samples will no longer damage the weighing unit. The surface below the scale of the halogen moisture analyzer is very flat and completely sealed, making it easy and fast to clean.