M411D AC/DC current and voltage meter
M411D AC/DC current and voltage meter
Product details

SC 7533 series
Three and a half digit voltmeter, ammeter, sensor secondary meter
Thank you for choosing the current and voltage meter produced by Idao company. Before use, please read these instructions for proper operation and installation of the connecting instrument.

Overview of functional components
1. Measurement process value display LED
2. Inaccurate calibration of instrument scale and adjustable potentiometer position correction
3. Inaccurate calibration of instrument zero point and adjustable potentiometer position

Voltage and current measurement

model Range (maximum resolution) Input impedance Input limit
SC7533-DV 19.99mV 1.999V
19.99V 199.9V
600V
>4Mohm 20%F.S
SC7533-DA 19.99mA 1.999A
5.00A standard 75mV input
<10hm 15%F.S
SC7533-AV
19.99V 199.9V
600V
>4Mohm 20%F.S
SC7533-AA 19.99mA 1.999A
Standard 5.00A input
<10hm 15%F.S
Measurement inaccuracy:0.5%F.STwo words
Explanation: When measuring AC current, if the input current is greater than 5A, an electrical transformer CT must be connected to the input terminal. CT
The secondary transformation ratio current is 5A.
When measuring AC voltage, if the input voltage is greater than 1000V, a voltage transformer PT must be connected to the input terminal. The secondary transformation ratio voltage of PT is 100V.
When measuring with a DC ammeter, if the input current is greater than 5A, a current divider must be connected to the input terminal, and the secondary voltage ratio of the divider is 75mV.
Technical Parameter Display mode
0.56 "red LED display measurement accuracy0.5%R.D
3Digital sampling period
2 times per second response time
0.25/second Overflow display
1 "or" -1 " series-mode rejection
>NMR 40dB(50Hz/60Hz) Polarity display
“-” Measurement method
Dual integration A/D conversion operating environment0-50
(Relative humidity 35% -85%) supply voltage
165V-265V 50Hz/60Hz Reactance strength
AC1500V/1 minute tested according to standard between terminals Dielectric Strength
<50MOHM (DC500V, tested according to standard between terminals)
others