Luminex multifunctional flow dot matrix analyzer Luminex 200



Product Description:

Luminex ® The 200TM multifunctional flow cytometer is one of Luminex's patented technology products and currently the highest rated high-throughput detection platform. The global installed capacity exceeds 10000 units. As of January 2009, over 48 products have been developed based on this technology platform, with a total of approximately 300 indicators that have passed strict validation by the US FDA and entered clinical applications. It also has China CFDA certification.

Application areas:
It involves infectious diseases detection, pharmacogenomics detection, personalized medical detection, HLA matching, autoimmune disease detection, allergen detection, gene mutation detection, tumor marker detection, HPV typing and many other fields. Testing 100 indicators at once can detect both proteins and nucleic acids, providing better services for clinical use and scientific research.


Product features:

  • High throughput, high speed
    • Each microsphere serves as a separate detection object and can perform a large number of biological tests simultaneously. Only 10-20 μ l of trace samples are needed to detect up to 100 indicators at once, with a maximum of 10000 tests per hour, truly achieving "high throughput" and "high speed"
  • Versatility
    • XMAP technology can be applied to various biological tests, including immune analysis, gene typing, gene expression, enzyme analysis, etc. It can detect both proteins and nucleic acids. In addition to clinical use, it can also be used for scientific research CDC、 Blood stations, agricultural and animal husbandry, biological and pharmaceutical professional laboratories, etc
  • High flexibility
    • Microspheres can be connected to specific probes, antigens, or antibodies to meet the needs of different customers
  • HIGH SENSITIVITY
    • The detection limit can reach 0.2pg/ml
  • good repeatability
    • Class homogeneous reaction mode, each indicator has 1000-5000 reaction units, analyze 100 times and take the median mean
  • High accuracy
    • The detection range reaches 3.5-6 orders of magnitude, with strong consistency with ELISA and mass spectrometry analysis
  • Low cost
    • Flow cytometry fluorescence technology requires a small amount of reagents for joint detection, which can effectively reduce the cost of clinical application