Kemu Electronics (Shanghai) Trading Co., Ltd
Home>Products>Lithium battery material moisture content analyzer MKC-710M/S+ADP-611
Lithium battery material moisture content analyzer MKC-710M/S+ADP-611
The lithium battery material moisture analyzer MKC-710M/S+ADP-611 is suitable for testing and analyzing the moisture content of lithium battery positi
Product details


Lithium battery material moisture content analyzer MKC-710M/S+MKV-710B+ADP-611

Coulombic Karl Fischer Moisture Analyzer MKC-710M/S
GB/T 19282-2014 Analysis Method for Lithium Hexafluorophosphate Products (Determination of Moisture)
HG/T 4066-2015 Lithium Hexafluorophosphate (Determination of Moisture)
HG/T 4067-2015 Lithium Hexafluorophosphate Electrolyte (Determination of Moisture)
HG/T 4790-2014 Fluorinated Ethylene Carbonate (Determination of Moisture)
HG/T 5157-2017 Diethyl Carbonate for Industrial Use (Determination of Moisture)
HG/T 5158-2017 Industrial Methyl Ethyl Carbonate (Determination of Moisture)
HG/T 5391-2018 Industrial Ethylene Carbonate (Determination of Moisture)
SJ/T 11568-2016 Electrolyte solvents for lithium-ion batteries (determination of moisture)
SJ/T 11723-2018 Electrolytes for Lithium ion Batteries (Determination of Moisture)
SJ/T 11724-2018 Electrolytes for Lithium Primary Batteries (Determination of Moisture)
SJ/T 11732-2018 Specification for Organic Electrolytes for Supercapacitors (Moisture Testing)
YS/T 1302-2019 Lithium Difluorosulfonylimide Electrolyte for Power Batteries (Determination of Moisture)

Coulombic Karl Fischer Moisture Analyzer MKC-710M/S+Karl Fischer Drying Furnace ADP-611
GB/T 24533-2019 Graphite based Negative Electrode Materials for Lithium ion Batteries (Appendix B Determination of Moisture Content)
GB/T 37386-2019 Activated Carbon (Moisture) for Supercapacitors
HG/T 5628-2019 Lithium Oxalate Borate (Determination of Moisture)

Capacity Karl Fischer Moisture Analyzer MKV-710B
GB/T 20252-2014 Lithium Cobaltate (Moisture Content)
GB/T 26031-2010 Lithium nickelate (moisture content)
GB/T 30835-2014 Carbon composite lithium iron phosphate cathode material for lithium-ion batteries (moisture content)
GB/T 30836-2014 Lithium titanate and its carbon composite negative electrode materials for lithium-ion batteries (moisture content)
GB/T 33822-2017 Nano Lithium Iron Phosphate (Determination of Moisture)
GB/T 3702-2018 Lithium nickel manganese oxide (moisture content)
YS/T 677-2016 Lithium Manganese Oxide (Determination of Moisture Content)
YS/T 798-2012 Lithium Nickel Cobalt Manganese Oxide (Determination of Moisture Content)
YS/T 825-2012 Lithium Titanate (Moisture Determination)
YS/T 1027-2015 Lithium Iron Phosphate (Determination of Moisture Content)
YS/T 1125-2016 Lithium Nickel Cobalt Aluminate (Determination of Moisture Content)
YS/T 1127-2016 Nickel Cobalt Aluminum Three Element Composite Hydroxide (Determination of Moisture Content)
YS/T 1030-2017 Rich lithium manganese based cathode material (moisture content)

Coulombic Karl Fischer moisture analyzerMKC-710M/SMain features:
1. Adopting a large 8.4-inch color LCD touch screen for operation and control.
2. The touch screen is operated through wireless Bluetooth, which is safer and reduces the risk.
3. After connecting the touch screen MCU-710 to the battery, it can be carried and operated.
4. User permission setting function to prevent incorrect settings and facilitate control.
5. Real time display of titration curve, moisture content, and parameters during the measurement process.
6. Rapid electrolysis rate of 2.6mgH2O/min to shorten measurement time.
7. The measurement results can be stored on a USB flash drive and generate PDF experimental reports.
8. Connect the ADP-611 furnace to automatically determine the appropriate heating temperature.

Coulombic Karl Fischer Moisture Analyzer MKC-710M/S Technical Parameters:

form

Automatic Karl Fischer moisture analyzer

Instrument model

MKC-710M

MKC-710S

Instrument composition

MCU-710M+MKC-710
Solvent exchange unit (optional)

MCU-710S+MKC-710
Solvent exchange unit (optional)

measuring method

Karl Fischer Coulomb electric quantity method

measuring range

Moisture content: 1μg~300mgH2O(1000mg)
Bromine Value Bromine Index Content

Measurement pool

Diaphragm type measuring cell or non diaphragm type measuring cell

Accuracy

Relative standard deviation: less than 0.3% (n=10), according to standard measurement methods and reference materials

Display resolution

0.1μg

Control method

Constant current pulse time control

Endpoint detection

Dual platinum detection electrode AC polarization method

End point judgment method

Drift stability judgment, or setting measurement time

Reagent demand

Anode solution: 100mL (150mL), catholyte: 5mL

measuring method

120 measurement methods

Key operation

touch screen

display

1) 8.4-inch color LCD screen, 800x600 dots

2) English/Japanese/Chinese/Korean/Russian/Spanish/German/French

3) Four channels are displayed simultaneously
(Can be connected to a potentiometric titrator or a volumetric/coulombic moisture analyzer simultaneously)

3) One channel display

calculation

Concentration calculation, statistical calculation (mean, standard deviation, relative standard deviation), automatic input of blank values

Data storage

500 sets of sample results

GLP certification

Register operator/use group management
Performance check: Remind the scheduled check date/record the check results
Trial drug lifespan: indicating the date of trial drug replacement and the responsiveness of the trial drug
Time management: Display operation time

External output

RS-232C × 4
Printer, electronic balance, data software (SOFT-CAP),
Moisture evaporator, multi sample automatic sampler

USB × 1
USB flash drive, thermal printer, A4 printer, keyboard, barcode machine, foot switch,
USB hub

SS-BUS X 1 : APB

LAN x 1 : Computer (PC)

Expand functions

Measurement unit:
Potentiometric titrator (AT-710)
Capacity Moisture Meter (MKV-710)
Coulombic Moisture Analyzer MKC-710
Four measuring units

Moisture evaporator: ADP-611


Fully automatic Karl·Free rest drying ovenADP-611Main features:
1. Connect the Karl Fischer moisture analyzer and control the operating program with the Karl Fischer moisture analyzer.
2. The sample boat is automatically fed into the heating furnace using magnetic force to reduce the influence of moisture.
3. Automatic scanning function for sample evaporation temperature to find the suitable heating temperature for the sample.
4. The pipeline from the heating furnace to the titration cup is equipped with a heating and insulation device to prevent low-temperature condensation.

Fully automatic Karl·Free rest drying ovenADP-611Technical parameters:
Temperature control range: 50-300 ° C.
Heater device: Pyrex glass tube, inner diameter 30X length 335mm.
Gas transmission: 1) Nitrogen, 2) Air pump (additional accessories to be purchased).
Gas drying: Zeolite desiccant X2.
Gas flow rate: 70-300 mL/min.

Capacity based Karl Fischer moisture analyzerMKV-710Bmain features:
1. The design of the driving part of the burette is compact and simple, occupying only A4 size.
2. The operation is very simple, just press the PRE-TITR and START keys to measure.
3. Equipped with a 1/20000 high-resolution burette, bubbles are not easily attached to the tube wall.
4. The measurement results can be stored on a USB drive and generate a PDF experimental report.
5. Built in a set of burette units, which can be expanded to two sets without increasing space.
6. The burette unit can be quickly replaced and maintained, facilitating the use of different titrants.
7. Simultaneously measure the moisture content using Coulomb method and volumetric method by connecting with MCU-710.

Capacity based Karl Fischer moisture analyzerMKV-710Btechnical parameter:
Name and Model: Karl Fischer Moisture Analyzer MKV-710B.
Instrument composition: MKV-710+solvent exchange unit (optional).
Measurement method: Karl Fischer titration method.
Measurement range: 1) Moisture content: 0.1-500mg H2O, 2) Moisture concentration: 10ppm~100% H2O.
Burette accuracy: burette volume: 10mL, accuracy: ± 0.015mL, repeatability: ± 0.005mL.
Endpoint determination: Determine the endpoint when the duration of the polarized potential is within the specified range, with endpoint time ranging from 1 to 99 seconds.
Titration form: forward titration/reverse titration (additional purchase of a second set of burettes is required).
Solvent demand: 30mL to 100mL (S-type titration cup).
Measurement methods: 20 sets of measurement methods.
Input settings: Key input.
Display: LCD display, available in six languages: Chinese, English, Japanese, Korean, Russian, and Spanish.
Calculation: concentration calculation, statistical calculation, automatic input of blank value and titration degree.
Data storage: 100 sets of sample results.
GLP certification: Registered operator/user group management, titrant management, performance testing, time management.
External output: RS-232C (printer/balance/data software/Karl Fischer oven), USB (USB flash drive/thermal printer/keyboard/barcode machine/foot switch/USB hub/Android device), SS-BUS(APB)。
Expansion function: Second set of burette driver unit.

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!