The LZ series metal tube float flowmeter adopts the principle of variable area measurement and is produced as a metal tube float flowmeter. A flowmeter mainly consists of three basic parts: 1. measuring tube body; 2. Cone shaped float; 3. Indicator. The displacement of the float is proportional to the flow rate, and through a magnetic coupling system, the displacement of the float is transmitted to the indicator in a non-contact manner to indicate the flow rate. Different converters can also be installed to convert flow values into standard 4-20mA electric remote transmission signals, achieving functions such as remote display, recording, integration, and control.
LZ series metal tube float flowmeter, suitable for measuring liquids and gases. In the design of measuring tubes, various structural types of measuring tubes have been configured for different pipeline conditions and special fluid measurement requirements, such as insulation jacket type, damper type, etc. In addition to standard options, special designs can also be made for users, such as high-pressure and high-temperature types, to meet their requirements to the greatest extent possible.
The LZ series metal tube float flowmeter can provide reliable and applicable functional combinations for various application scenarios in indicator design. As indicated by on-site pointers, LCD displays instantaneous and cumulative flow rates, etc. In terms of indicator power supply selection, there are battery power supply, 24VDC power supply, and 220VAC power supply, which are convenient for users to choose based on on-site conditions. The LZ series metal tube float flowmeter is widely used in industries such as petroleum, chemical, power plants, food, pharmaceutical, water treatment, and other fields due to its simple structure, long service life, linear scale, and ability to measure liquids and gases.
■Technical Parameter
Square indicator
Circular indicator
Instrument model
LZ series metal tube float flowmeter
Medium temperature -80 ∽ 200 ℃ standard type
measuring range
(Point value) Select from flow chart
0-85 ℃ anti-corrosion type (fluorine lined)
water
20℃ 2.5-150,000L/h
-80-300 ℃ high temperature type
Air 1.013bar ABS 20 ℃ 0.07-3000m ³/h
Environmental temperature -25 ∽ 60 ℃
Range ratio
10: 1 5:1
Protection level IP65
accuracy class
1.5 2.5
Electrical signal output signal 4-20mA (two-wire system)
pressure loss
Refer to the flow chart
Linearity 1%
Measuring tube
Orifice measuring tube Cone measuring tube
Temperature effect 0.5%/10 ℃
scale division
Divided by traffic units
Electrical interface M20 × 1.5 standard type
Instrument caliber
DN15-DN150
Power supply 24V DC standard type
Flange connection
DN15-DN50/PN4.0 DN80-DN150/PN1.6
Power consumption ≤ 3W
Flange standard
GB/T9119-2000
Limit alarm power supply 24V DC
It can also be manufactured according to the flange standards provided by the user
Power consumption ≤ 3W
Insulation jacket flange DN15 DN25/PN4.0
Contact capacity 3A/220V
Insulation jacket
Φ20
Working temperature -25 ∽ 60 ℃
special type
High pressure type, threaded type, and other special types
Explosion proof grade Exib Ⅱ CT5 Exd Ⅱ BT5
Viscosity
DN15≤5mPa.s
Explosion proof related equipment
Intrinsic safety barrier LB906
DN25~ DN150≤250mPa.s
LZZLocal indication type
LZDElectric remote transmission type
caliber
15
20
25
32
40
50
65
80
100
125
150
structural style
F10 bottom in top out type (can be default)
F11 lower inlet side outlet type
F12 side in side out type
F13 right in left out type
F14 left in right out type
Liquid receiving material
RR0
316 / 0Cr18Ni12Mo2Ti
Applicable to structural types
F10
F11
F12
F13
F14
RR1
304 / 1Cr18Ni9Ti
F10
F11
F12
F13
F14
RL
316L
F10
F11
F12
F13
F14
RP
PTFE
F10
Ti
titanium alloy
F10
HC
Hastelloy alloy
F10
additional structure
T
Jacket type
Suitable for measuring device types
F10
Z
Damping type
F10
F11
F12
F13
F14
G
High temperature type
F10
F11
F12
F13
F14
Y
High pressure
F10
F11
F12
F13
F14
indicator
(For remote transmission 4-20mA standard current signal indicators,+HART protocol can be selected)
On site pointer displays instantaneous flow rate
24VDC power supply, on-site pointer displays instantaneous flow, non-contact transmitter, remote transmission of 4-20mA standard current signal
Equipped with an upper limit alarm point output
Equipped with a lower limit alarm point output
Equipped with an upper limit and a lower limit alarm point outputdefault
ES
K1
K2
K12
JSB
Battery powered,
LCD displays instantaneous flow and cumulative flowJSC
240VAC power supply, LCD displays instantaneous flow and cumulative flow
24V DC power supply, LCD displays instantaneous flow and cumulative flow
24V DC power supply, LCD display for instantaneous and cumulative flow, remote transmission of 4-20mA standard current signal
For remote transmission of 4-20mA standard current signal indicators, the+HART protocol can be selectedJSD
JSE
HART
Explosion proof type
default
Common
Square indicator
Exi
Intrinsic safety explosion-proof type
Square indicator
Exd
Explosion proof type
Circular indicator
Example: LZ □ - □□□□□□□ Note: No options can be left blank. LZ D-15 /F10/RR0/T/ES/HART/Exi
Description: Electric remote transmission/DN15 caliber/bottom in and top out type/material 0Cr18Ni12Mo2Ti/jacket type/4-20mA/HART protocol/intrinsic safety explosion-proof
caliber
Water (L/h) 20 ℃ 101325Pa
Air (m ³/h) 20 ℃ 101325Pa.abs
High pressure loss (Kpa)
Material RRO RR1 RL
Material PTFE
Material RRO RR1 RL
Material RRO RR1 RL
Material PTFE
15
2.5-25
0.07-0.7
6.5
4-40
2.5-25
0.11-1.1
6.5
5.5
6-60
4-40
0.18-1.8
6.6
5.5
10-100
6-60
0.28-2.8
6.6
5.6
16-160
10-100
0.4-4.0
6.8
5.8
25-250
16-160
0.7-7.0
7.2
6.1
40-400
25-250
1.0-10
8.6
6.1
60-600
40-400
1.6-16
11.1
7.3
25
100-1000
60-600
3.0-30
7.0
5.9
160-1600
100-1000
4.5-45
8.0
6.0
250-2500
160-1600
7-70
10.8
6.8
400-4000
250-2500
11-110
15.8
9.2
50
600-6000
250-2500
18-180
8.0
6.5
1000-10000
400-4000
25-250
11.0
6.8
1600-16000
600-6000
40-400
16.2
9.4
2000-20000
1000-10000
60-600
16.2
14.5
80
2500-25000
1600-16000
60-600
8.2
6.9
4000-40000
2000-20000
100-1000
9.5
8.1
5000-50000
2500-25000
150-1500
9.5
8.1
100
6000-60000
4000-40000
180-1800
8.0
9.5
8000-80000
5000-50000
240-2400
10.0
9.2
10000-100000
8000-80000
300-3000
10.0
9.2
125
10000-100000
8000-80000
300-3000
10.0
8.5
25000-125000
10000-100000
12.2
10.1
150
25000-125000
10000-100000
11.0
9.2
30000-150000
30000-125000
13.2
12.1
Note: When used for measuring liquids, it should be ensured that the working pressure is not less than twice the pressure loss; When used for measuring gases, it should be ensured that the working pressure is not less than five times the pressure loss to ensure stable operation of the flowmeter; 2. Customized specifications such as DN20, DN32, DN40, DN65 can be made according to user requirements.
■magnetic filter:
If the medium contains ferromagnetic particles, a magnetic filter should be installed at the inlet of the flowmeter. The magnetic filter is equipped with magnetic rods arranged in a spiral pattern to minimize pressure loss. There are two types of magnetic filters that are suitable for all instrument sizes. The material is 304, 316 or 316L. When used for corrosive media, the cylinder and magnetic rod are wrapped in PTFE to prevent corrosion by the medium. The flange connection size of the magnetic filter is the same as the corresponding flowmeter.■damping:
If the inlet flow rate (pressure) of the flowmeter is unstable, especially for gas measurement, a damper structure is designed to ensure the measurement accuracy of the instrument and extend its service life. Its structure is shown in the figure.
For gases with small particles or dust, dampers are not suitable for use. In this situation, to ensure normal operation, it is required that the inlet pressure be greater than 5 times the instrument pressure loss. For DN15 caliber, a pressure regulator (constant current regulator) can also be used to stabilize the flow rate.■ Signal wiring:
Electric signal output power supply 24V DC standard type
Output signal 4-20mA (two-wire system) linearity 1% temperature effect 0.5%/10 ℃
High load resistance 270 Ω (24V DC)
Electrical interface M20 × 1.5 standard type
Power consumption ≤ 3W
Explosion proof grade ib Ⅱ CT5
Explosion proof associated equipment safety barrier LB906Intrinsic safety explosion-proof system
The LZD series metal tube float flowmeter must be used in conjunction with the LB906 Zener safety barrier to form an intrinsically safe explosion-proof system. The wiring of this security system should avoid the influence of external electromagnetic interference as much as possible, and the cable distribution parameters should be controlled within 0.08 μ F and 2 mH. The high operating voltage of the control room instruments connected to the safety barrier or the high voltage that may be generated internally shall not exceed 250V rms. The safety barrier must be installed in a safe place. The installation, use, and maintenance of safety barriers should comply with the user manual. Users must carefully read the product manual and comply with the "Electrical Safety Regulations for Explosive Hazardous Areas of the People's Republic of China" when installing, using, and maintaining the LZD series metal tube float flowmeter.
The casing of the metal tube float flowmeter is equipped with a grounding terminal, and users should ensure reliable grounding during use.Upper and lower limit alarm switch:
The limit switch alarm device of LZ series metal tube float flowmeter consists of limit pointer, contactless switch, asymptotic board, built-in amplification relay, and power supply. The power supply needs to be installed separately. When the asymptotic board passes through the gap of the contactless switch, an alarm signal is generated. Users can install one or two alarm systems as needed, and the switch points can be set through the limit pointer on the dial to achieve preset alarms for the upper, lower, or upper and lower limits of any flow rate. The position of the limit pointer simultaneously indicates the limit value.
Limit alarm power supply 24V DC; Power consumption ≤ 3W; Contact capacity 3A/220V; Working temperature -25 ° C to 60 ° C. The limit switch alarm device adopts a pre-set conversion amplification relay in the table, which directly outputs a contact capacity of 3A/220V normally open (standard type) or normally closed signal.
Attributes [Origin] Chinese Mainland [Flow meter type] rotameter