major function
lAutomatically restore network connections and establish reliable onesTCPconnect;
lSupport simultaneous with4The function of connecting and communicating with a server;
lThe RS485 serial port baud rate can be set to 1200~Common values between 115200bps;
lSupport data collection for various types of energy metering devices, including electric energy meters (including single-phase electric energy meters, three-phase electric energy meters, multifunctional electric energy meters), power monitoring devices, electricity measurement modules, water meters, gas meters, cold and hot meters, flow meters, etc;
lSupports multiple instrument communication protocols, includingModbus RTU protocol, multifunctional energy meter communication protocolDL/T 645—1997、CJ/T 188-2004Agreements, etc;
lsupport128tower800A collection point;
lSupports two data collection modes: data collection based on data center commands and active timed collection, with a collection cycle that can be from1Minutes to2Flexible hourly configuration;
l2GB dedicated storage space supports at least1Backup of energy consumption data for years or more;
lSupport breakpoint resume function. Due to transmission network failures and other factors, the collected energy consumption data cannot be transmitted remotely on time. After the transmission network is restored to normal, the data collector can resume the collection of historical energy consumption data at breakpoints;
lSupport the localization and diagnosis of faults in the data collection system, and enable the reporting of fault information to the data center;
lSupporting visual data services and management software;
lSupport software upgrades;
lIn addition to the above functions, it also meets the other functional requirements of the data collector in the technical guidelines of the "Energy Consumption Monitoring System for State Office Buildings and Large Public Buildings".
Flexible configuration method
lCan be done throughWEBBrowser configuration system and operating parameters;
lCan be accessed through an independent super terminalConsoleSerial port configuration system and operating parameters;
lThe system and operating parameters can be configured through data collection management software.
lAutomatically restore network connections and establish reliable onesTCPconnect;
lSupport simultaneous with4The function of connecting and communicating with a server;
lThe RS485 serial port baud rate can be set to 1200~Common values between 115200bps;
lSupport data collection for various types of energy metering devices, including electric energy meters (including single-phase electric energy meters, three-phase electric energy meters, multifunctional electric energy meters), power monitoring devices, electricity measurement modules, water meters, gas meters, cold and hot meters, flow meters, etc;
lSupports multiple instrument communication protocols, includingModbus RTU protocol, multifunctional energy meter communication protocolDL/T 645—1997、CJ/T 188-2004Agreements, etc;
lsupport128tower800A collection point;
lSupports two data collection modes: data collection based on data center commands and active timed collection, with a collection cycle that can be from1Minutes to2Flexible hourly configuration;
l2GB dedicated storage space supports at least1Backup of energy consumption data for years or more;
lSupport breakpoint resume function. Due to transmission network failures and other factors, the collected energy consumption data cannot be transmitted remotely on time. After the transmission network is restored to normal, the data collector can resume the collection of historical energy consumption data at breakpoints;
lSupport the localization and diagnosis of faults in the data collection system, and enable the reporting of fault information to the data center;
lSupporting visual data services and management software;
lSupport software upgrades;
lIn addition to the above functions, it also meets the other functional requirements of the data collector in the technical guidelines of the "Energy Consumption Monitoring System for State Office Buildings and Large Public Buildings".
Flexible configuration method
lCan be done throughWEBBrowser configuration system and operating parameters;
lCan be accessed through an independent super terminalConsoleSerial port configuration system and operating parameters;
lThe system and operating parameters can be configured through data collection management software.