Kipp&Zonen Solrad handheld radiation data measuring instrument
Kipp&Zonen Solrad handheld radiation data measuring instrument
Product details

Solrad handheld radiation data measuring instrument is a convenient and fast data acquisition and measurement instrument. It can easily connect various radiation sensors of Kipp&Zonen, conveniently and quickly read measurement data, and can be widely used in fields such as meteorology, agriculture, industry, and education.

The built-in monitor of Solrad can display the radiation values measured by the Kipp&Zonen radiation sensors connected to it. The measuring instrument can refer to the calibration coefficient of the sensor when reading measurement data, so the measurement value displayed on the monitor is the automatically calibrated value.

Solrad can also integrate the measured radiation values, and the integration setting can be manually reset or automatically reset. Automatic reset is performed at zero time (controlled by the built-in clock). The integrated value will be stored in the memory, and up to 31 sets of radiation values can be stored.

According to actual needs, Solrad can automatically record values and retain the measurement values for each day of the month in memory.

You can connect the Solrad handheld radiation data measuring instrument and computer together through the computer's COM interface (RS-232), and import the actual measured data and integrated values of Solrad into your computer through the operating software. The data stored on the computer can be further processed using data processing software such as Excel.

Main technical parameters

Function: Real time display or reading of integration values, reset mode after integration, manual or automatic setting of internal clock. Can store up to 31 sets of integral values

Matching sensor types: CMP, CM4, SP/PAR LITE2, CUV5, UVS series

A/D conversion resolution: 1:10.000

Offset:< 5 μ V (at -20 ℃~40 ℃)

Linear error:< 1 LBS

Conversion rate:>10 sample values/s

Integral: The integral value is updated every two seconds, and the maximum integral value for all sensors is 231

Power supply: 9VDC (standard); 8~24VDC, maximum 50mA

Battery life:>25 hours (alkaline battery, model PP3); Or use a DC power adapter

Interface: RS232 (9600 baud rate)

Working temperature:- 10℃~40℃

Size: 100cm × 197cm × 50mm

Weight: 450g