1、 Product Introduction: LT-UHZ series magnetic flap (column) level gauge, made of high-quality stainless steel material, is suitable for measuring th
Product details
1、 Product Introduction:
LT-UHZ seriesMagnetic flip plate (column) level gaugeMade of high-quality stainless steel materials, it is suitable for measuring the medium liquid level of various towers, tanks, tank ball descriptors, boilers and other equipment. The entire process of measurement is highly sealed, leak proof, and has no blind spots. The display is eye-catching, the reading is intuitive, and the measurement range is large. First, equip a limit switch to achieve upper and lower limit alarm and control of liquid level. Optional liquid level transmitter can convert liquid level signals into 4-20mADC standard signals, enabling remote detection, indication, recording, and control. This series of products is widely used for liquid level measurement and control of various towers, tanks, tanks, and boiler equipment in the production processes of industries such as power, petroleum, chemical, metallurgical, environmental protection, shipbuilding, and construction. This series of products complies with the HG/T21584-95 magnetic liquid level juice industry standard of the Ministry of Chemical Industry.
2、 Structural principle:
The liquid level gauge works based on the principles of buoyancy and magnetic coupling. When the liquid in the side container rises and falls, the float in the main tube of the level gauge also rises and falls accordingly. The permanent magnetic steel inside the float is transmitted to the on-site indicator through magnetic coupling, driving the red and white flip column to flip 180 °. When the liquid level rises, the flip column changes from white to red, and when the liquid level drops, it changes from red to white. The red and white boundary of the indicator is the actual height of the medium liquid level in the container, thus achieving the indication of the liquid level. Install limit switches to achieve liquid level alarm and control, and install transmitters to achieve standard signal output for display and control.
3、 Installation diagram:


4、 Technical parameters:
Measurement range: 0-150-6000mm (can be negotiated for orders larger than 6000mm), accuracy: ± 10mm
Medium density: 0.4-20g/cm3, medium density difference: ≥ 0.15g/cm3
Work pressure:- 0.1-42MPa
Working temperature:- 160-450℃
Connection flange: The flange diameter is DN20-DN150, and the flange standard adopts the HG20592-97 flange standard of the Ministry of Chemical Industry. For other flange standards, please indicate them when ordering.
Environmental vibration: frequency ≤ 25HZ, amplitude ≤ 0.5mm.
Flange material: carbon steel, 304, 316L
Follow speed: ≤ 0.08m/s
Medium viscosity: ≤ 0.04Pa
Main tube material: 1Cr18Ni9Ti, 304, 316L PP、PTEE, 304 stainless steel lined with PTEE.
Main pipe diameter: ¢ 48, ¢ 57, ¢ 62mm.
Magnetic flip column material: ≤ 80 ℃: ABS plastic, ≥ 80 ℃: ceramic or metal.
Display material: ≤ 80 ℃: ABS plastic, ≥ 80 ℃: aluminum alloy.
Installation method: Vertical installation.
Discharge valve: ball valve, needle valve.
5、 Product features:
LT-UHZ seriesMagnetic flip plate (column) level gaugeThe components are made of 1Cr8NiTi, 316L, 304 stainless steel lined with PTEE (polytetrafluoroethylene), PVC, PP and other materials, as well as imported components, which have excellent reliability and corrosion resistance. Its characteristics are very significant:
The design is simple, compact, sturdy and reliable, with a long lifespan and no maintenance work required for long-term outdoor installation and use;
The measuring tube is completely isolated from the liquid level display part, liquid level transmitter, and alarm switch in terms of pressure resistance and gas resistance;
Wide range of working pressure, with pressure resistance ranging from vacuum to 42MPa;
Wide working temperature range, suitable for temperatures ranging from -160-450 ℃;
Widely used for measuring liquid levels that are highly corrosive, flammable, explosive, toxic, highly radioactive, agitated, and contaminated;
All models can choose the Dingyou magnetic alarm switch to achieve automatic control or alarm of high and low liquid levels;
Each model can be equipped with a 4-20mADC liquid level transmitter for remote centralized measurement and control.
6、 Product target audience:
LT-UHZ seriesMagnetic flip plate (column) level gaugeIt can be widely used in various industries such as petroleum, chemical, oil field, medicine, food, and wine industry to measure and display the liquid level, liquid level, and interface between 1Cr8NiTi, 304+PTEE (polytetrafluoroethylene), 316L, PVC, PP compatible liquid media in storage tanks, tanks, reaction tanks, fermentation tanks, oil fields, liquefied gas, liquid hydrogen, strong acid and alkali liquids, weak acid and alkali liquids, power plant boiler steam drums, high and low pressure heaters, deaerators, drain tanks, return water tanks, high and low pressure heaters, condensers, evaporators, and other pressure vessels. There are multiple installation forms for you to choose from to meet the requirements of different occasions and environments.
7、 Additional function options:
Magnetic limit switch:
Normally open: merge above the alarm point
Normally closed: disconnected above the alarm point
Switch capacity: 250VAC1A (resistive) 250VAC0.3A (inductive)
Switch lifespan: 100000 cycles
Liquid level transmitter:
Output current: 4-20mADC
Resolution: ± 1- ± 10mm
Load resistance: 500 Ω (when powered by 24VDC)
Transmission distance:> 3000m
Working power supply: 16-30VDC
Intelligent liquid level transmitter:
Output current: 4-20ADC
Resolution: 0.2mm
Load resistance: 500 Ω (when powered by 24VDC)
Transmission distance:> 3000m
Working power supply: 16-30VDC
Form of jacket:
Steam jacket and water circulation jacket are a layer of cylinder added to the main pipe of the liquid level gauge for the circulation of steam, circulating water or thermal oil.
Vacuum jacket is a layer of vacuum cylinder added outside the main tube of the liquid level gauge to insulate the measured medium from the outside.
Double layered jacket generally refers to adding another layer of vacuum jacket outside the steam tracing jacket.
The electric heat tracing system wraps an electric heat tracing strip around the main pipe of the liquid level gauge to heat the medium.

[Return to previous page]
Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!