ISWHB horizontal stainless steel explosion-proof pipeline pumpsummary:
ISWHB horizontal stainless steel explosion-proof pipeline pumpAccording to the IS typecentrifugal pumpA high-efficiency and energy-saving product designed with a unique structural combination and manufactured strictly in accordance with international standard ISO2858 and the latest national pipeline centrifugal pump standard JB/T53058-93. The pump is optimized and designed using advanced hydraulic models in China. At the same time, depending on the usage temperature, medium, etc., in the ISW typePipeline pumpBased on this, hot water pumps, high-temperature pumps, chemical pumps, oil pumps, etc. have been derived, which are currently standardized and promoted products in China.
ISWHB horizontal stainless steel explosion-proof pipeline pumpcharacteristic:
Smooth operation: The absolute concentricity of the pump shaft and excellent dynamic and static balance of the impeller ensure smooth operation without any vibration.
Drip proof: Hard alloy seals made of different materials ensure that there is no leakage during the transportation of different media.
Low noise: The water pump supported by two low-noise bearings runs smoothly, with almost no noise except for weak motor noise.
Low failure rate: The structural reinforcement is reasonable, and the key parts are matched with international first-class quality, greatly improving the fault free working time of the whole machine.
Easy maintenance: Replacing seals and bearings is simple and convenient.
More land saving: The exit can be arranged in three directions: left, right, and up, which is convenient for pipeline layout and installation, saving space.
ISWHB horizontal stainless steel explosion-proof pipeline pumpWorking conditions:
1. The suction pressure is ≤ 1.0Mpa, or the maximum working pressure of the pump system is ≤ 1.6Mpa, that is, the pump suction inlet pressure+pump head is ≤ 1.6Mpa, and the pump static pressure test pressure is 2.5Mpa. Please specify the system working pressure when ordering. When the working pressure of the pump system is greater than 1.6Mpa, it should be separately stated when ordering. In order to use cast steel materials for the overcurrent components and connecting parts of the pump during manufacturing.
2. Environmental temperature<40 ℃, relative humidity<95%.
3. The volume content of solid particles in the conveyed medium shall not exceed 0.1% of the unit volume, and the particle size shall be less than 0.2mm
Note: If the medium used is with small particles, please specify when ordering so that wear-resistant mechanical seals can be used.
ISWHB horizontal stainless steel explosion-proof pipeline pumpMain purpose:
1ISW horizontal pipeline centrifugal pumpUsed for transporting clean water and other liquids with physical and chemical properties similar to clean water, suitable for industrial and urban water supply and drainage, high-rise building pressurized water supply, garden irrigation, fire pressure boosting, and equipment matching. Operating temperature T: ≤ 80 ℃.
2ISWR hot water pipeline pump | circulating pumpWidely applicable to energy, metallurgy, chemical, textile, papermaking, as well as hotels, restaurants and other boiler high-temperature hot water pressurized circulation transportation and urban heating system circulation pumps, ISWR operating temperature T: ≤ 120 ℃, WRG operating temperature T: ≤ 240 ℃.
3ISWH Stainless Steel Chemical Pipeline PumpFor conveying liquids that do not contain solid particles, are corrosive, and have a viscosity similar to water. They are suitable for industries such as petroleum, chemical, metallurgical, power, papermaking, food, pharmaceuticals, and synthetic fibers. The operating temperature is T:- 20 ℃ -120 ℃.
4ISWB horizontal pipeline oil pumpUsed for transporting petroleum products such as gasoline, diesel, kerosene, etc., operating temperature T:- 20 ℃ -120 ℃.
5ISWD series horizontal low-speed pumpAdapt to situations where low environmental noise is required.
ISWHB horizontal stainless steel explosion-proof pipeline pump technology selection:
Oil pump Model |
internet traffic |
lift |
efficiency |
rotational speed |
Motor Power |
Cavitation residue |
|
(m 3 /h) |
(l/s) |
||||||
15-80 |
1.5 |
0.42 |
8 |
34 |
2800 |
0.18 |
2.3 |
20-110 |
2.5 |
0.69 |
15 |
34 |
2800 |
0.37 |
2.3 |
20-160 |
2.5 |
0.69 |
32 |
25 |
2900 |
0.75 |
2.3 |
25-110 |
4 |
1.11 |
15 |
42 |
2900 |
0.55 |
2.3 |
25-125 |
4 |
1.11 |
20 |
36 |
2900 |
0.75 |
2.3 |
25-125A |
3.6 |
1.0 |
16 |
35 |
2900 |
0.55 |
2.3 |
25-160 |
4 |
1.11 |
32 |
32 |
2900 |
1.5 |
2.3 |
25-160A |
3.7 |
1.03 |
28 |
31 |
2900 |
1.1 |
2.3 |
32-125 |
5 |
1.39 |
20 |
44 |
2900 |
0.75 |
2.3 |
32-125A |
4.5 |
1.25 |
16 |
43 |
2900 |
0.5 |
2.3 |
40-100 |
6.3 |
1.75 |
12.5 |
54 |
2900 |
0.55 |
2.3 |
40-100A |
5.6 |
1.56 |
10 |
52 |
2900 |
0.37 |
2.3 |
40-125 |
6.3 |
1.75 |
20 |
46 |
2900 |
1.1 |
2.3 |
40-125A |
5.6 |
1.56 |
16 |
45 |
2900 |
0.75 |
2.3 |
40-160 |
6.3 |
1.75 |
32 |
40 |
2900 |
2.2 |
2.3 |
40-160A |
5.9 |
1.64 |
28 |
39 |
2900 |
1.5 |
2.3 |
40-160B |
5.5 |
1.53 |
24 |
38 |
2900 |
1.1 |
2.3 |
40-200 |
6.3 |
1.75 |
50 |
33 |
2900 |
4.0 |
2.3 |
40-200A |
5.9 |
1.64 |
44 |
31 |
2900 |
3.0 |
2.3 |
40-200B |
5.3 |
1.47 |
36 |
29 |
2900 |
2.2 |
2.3 |
40-250 |
6.3 |
1.75 |
80 |
28 |
2900 |
7.5 |
2.3 |
40-250A |
5.9 |
1.64 |
70 |
28 |
2900 |
5.5 |
2.3 |
40-250B |
5.5 |
1.53 |
60 |
27 |
2900 |
4.0 |
2.3 |
40-100(I) |
12.5 |
3.47 |
12.5 |
62 |
2900 |
1.1 |
2.3 |
40-100(I)A |
11 |
3.05 |
10 |
60 |
2900 |
0.75 |
2.3 |
40-125(I) |
12.5 |
3.47 |
20 |
58 |
2900 |
1.5 |
2.3 |
40-125(I)A |
11 |
3.05 |
16 |
57 |
2900 |
1.1 |
2.3 |
40-160(I) |
12.5 |
3.47 |
32 |
52 |
2900 |
3.0 |
2.3 |
40-160(I)A |
11.7 |
3.25 |
28 |
51 |
2900 |
2.2 |
2.3 |
40-160(I)B |
10.4 |
2.89 |
22 |
50 |
2900 |
1.5 |
2.3 |
40-200(I) |
12.5 |
3.47 |
50 |
46 |
2800 |
5.5 |
2.3 |
40-200(I)A |
11.7 |
3.25 |
44 |
45 |
2900 |
4.0 |
2.3 |
40-200(I)B |
10.6 |
2.94 |
36 |
44 |
2900 |
3 |
2.3 |
40-250(I) |
12.5 |
3.47 |
80 |
38 |
2900 |
11 |
2.3 |
40-250(I)A |
11.6 |
3.22 |
70 |
38 |
2900 |
7.5 |
2.3 |
40-250(I)B |
10.8 |
3.0 |
60 |
37 |
2900 |
7.5 |
2.3 |
40-250(I)C |
10.0 |
2.78 |
52 |
36 |
2900 |
5.5 |
2.3 |
50-100 |
12.5 |
3.47 |
12.5 |
62 |
2900 |
1.1 |
2.3 |
50-100A |
11 |
3.05 |
10 |
60 |
2900 |
0.75 |
2.3 |
50-125 |
12.5 |
3.47 |
20 |
58 |
2900 |
1.5 |
2.3 |
50-125A |
11 |
3.05 |
16 |
57 |
2900 |
1.1 |
2.3 |
50-160 |
12.5 |
3.47 |
32 |
52 |
2900 |
3.0 |
2.3 |
50-160A |
11.7 |
3.25 |
28 |
51 |
2900 |
2.2 |
2.3 |
50-160B |
10.4 |
2.89 |
22 |
50 |
2900 |
1.5 |
2.3 |
50-200 |
12.5 |
3.47 |
50 |
46 |
2900 |
5.5 |
2.3 |
50-200A |
11.7 |
3.25 |
44 |
45 |
2900 |
4.0 |
2.3 |
50-200B |
10.6 |
2.94 |
36 |
44 |
2900 |
3 |
2.3 |
50-250 |
12.5 |
3.47 |
80 |
38 |
2900 |
11 |
2.3 |
50-250A |
11.6 |
3.22 |
70 |
38 |
2900 |
7.5 |
2.3 |
50-250B |
10.8 |
3.0 |
60 |
37 |
2900 |
7.5 |
2.3 |
50-250C |
10.0 |
2.78 |
52 |
36 |
2900 |
5.5 |
2.3 |
50-100(I) |
25 |
6.94 |
12.5 |
69 |
2900 |
1.5 |
2.5 |
50-100(I)A |
22.3 |
6.19 |
10 |
67 |
2900 |
1.1 |
2.5 |
50-125(I) |
25 |
6.94 |
20 |
68 |
2900 |
3.0 |
2.5 |
50-125(I)A |
22.3 |
6.19 |
16 |
66 |
2900 |
2.2 |
2.5 |
50-160(I) |
25 |
6.94 |
32 |
63 |
2900 |
4.0 |
2.5 |
50-160(I)A |
23.4 |
6.5 |
28 |
62 |
2900 |
4.0 |
2.5 |
50-160(I)B |
21.6 |
6.0 |
24 |
58 |
2900 |
3.0 |
2.5 |
50-200(I) |
25 |
6.94 |
50 |
58 |
2900 |
7.5 |
2.5 |
50-200(I)A |
23.5 |
6.53 |
44 |
57 |
2900 |
7.5 |
2.5 |
50-200(I)B |
21.8 |
6.06 |
38 |
55 |
2900 |
5.5 |
2.5 |
50-250(I) |
25 |
6.94 |
80 |
50 |
2900 |
15 |
2.5 |
50-250(I)A |
23.4 |
6.5 |
70 |
50 |
2900 |
11 |
2.5 |
50-250(I)B |
21.6 |
6.0 |
60 |
49 |
2900 |
11 |
2.5 |
50-315(I) |
25 |
6.94 |
125 |
40 |
2900 |
30 |
2.5 |
50-315(I)A |
23.7 |
6.58 |
113 |
40 |
2900 |
22 |
2.5 |
50-315(I)B |
22.5 |
6.25 |
101 |
39 |
2900 |
18.5 |
2.5 |
50-315(I)C |
20.6 |
5.72 |
85 |
38 |
2900 |
15 |
2.5 |
Pump model |
internet traffic |
lift |
efficiency |
rotational speed |
Motor Power |
Cavitation residue |
|
(m 3 /h) |
(l/s) |
||||||
65-100 |
25 |
6.94 |
12.5 |
69 |
2900 |
1.5 |
2.5 |
65-100A |
22.3 |
6.19 |
10 |
67 |
2900 |
1.1 |
2.5 |
65-125 |
25 |
6.94 |
20 |
68 |
2900 |
3.0 |
2.5 |
65-125A |
22.3 |
6.19 |
16 |
66 |
2900 |
2.2 |
2.5 |
65-160 |
25 |
6.94 |
32 |
63 |
2900 |
4.0 |
2.5 |
65-160A |
23.4 |
6.5 |
28 |
62 |
2900 |
4.0 |
2.5 |
65-160B |
21.6 |
6.0 |
24 |
58 |
2900 |
3.0 |
2.5 |
65-200 |
25 |
6.94 |
50 |
58 |
2900 |
7.5 |
2.5 |
65-200A |
23.5 |
6.53 |
44 |
57 |
2900 |
7.5 |
2.5 |
65-200B |
21.8 |
6.06 |
38 |
55 |
2900 |
5.5 |
2.5 |
65-250 |
25 |
6.94 |
80 |
50 |
2900 |
15 |
2.5 |
65-250A |
23.4 |
6.5 |
70 |
50 |
2900 |
11 |
2.5 |
65-250B |
21.6 |
6.0 |
60 |
49 |
2900 |
11 |
2.5 |
65-315 |
25 |
6.94 |
125 |
40 |
2900 |
30 |
2.5 |
65-315A |
23.7 |
6.58 |
113 |
40 |
2900 |
22 |
2.5 |
65-315B |
22.5 |
6.25 |
101 |
39 |
2900 |
18.5 |
2.5 |
65-315C |
20.6 |
5.72 |
85 |
38 |
2900 |
15 |
2.5 |
65-100(I) |
50 |
13.9 |
12.5 |
73 |
2900 |
3.0 |
3.0 |
65-100(I)A |
44.7 |
12.4 |
10 |
72 |
2900 |
2.2 |
3.0 |
65-125(I) |
50 |
13.9 |
20 |
72.5 |
2900 |
5.5 |
3.0 |
65-125(I)A |
45 |
12.5 |
16 |
71 |
2900 |
4.0 |
3.0 |
65-160(I) |
50 |
13.9 |
32 |
71 |
2900 |
7.5 |
3.0 |
65-160(I)A |
46.7 |
13.0 |
28 |
70 |
2900 |
7.5 |
3.0 |
65-160(I)B |
43.3 |
12.0 |
24 |
69 |
2900 |
5.5 |
3.0 |
65-200(I) |
50 |
13.9 |
50 |
67 |
2900 |
15 |
3.0 |
65-200(I)A |
47 |
13.1 |
44 |
66 |
2900 |
11 |
3.0 |
65-200(I)B |
43.5 |
12.1 |
38 |
65 |
2900 |
7.5 |
3.0 |
65-250(I) |
50 |
13.9 |
80 |
59 |
2900 |
22 |
3.0 |
65-250(I)A |
46.7 |
13.0 |
70 |
59 |
2900 |
18.5 |
3.0 |
65-250(I)B |
43.3 |
12.0 |
60 |
58 |
2900 |
15 |
3.0 |
65-315(I) |
50 |
13.9 |
125 |
54 |
2900 |
37 |
3.0 |
65-315(I)A |
46.5 |
12.9 |
110 |
54 |
2900 |
30 |
3.0 |
65-315(I)B |
44.5 |
12.4 |
100 |
53 |
2900 |
30 |
3.0 |
65-315(I)C |
41 |
11.4 |
85 |
51 |
2900 |
22 |
3.0 |
80-100 |
50 |
13.9 |
12.5 |
73 |
2900 |
3.0 |
3.0 |
80-100A |
44.7 |
12.5 |
10 |
72 |
2900 |
2.2 |
3.0 |
80-125 |
50 |
13.9 |
20 |
72.5 |
2900 |
5.5 |
3.0 |
80-125A |
45 |
12.5 |
16 |
71 |
2900 |
4.0 |
3.0 |
80-160 |
50 |
13.9 |
32 |
71 |
2900 |
7.5 |
3.0 |
80-160A |
46.7 |
13.0 |
28 |
70 |
2900 |
7.5 |
3.0 |
80-160B |
43.3 |
12.0 |
24 |
69 |
2900 |
5.5 |
3.0 |
80-200 |
50 |
13.9 |
50 |
67 |
2900 |
15 |
3.0 |
80-200A |
47 |
13.1 |
44 |
66 |
2900 |
11 |
3.0 |
80-200B |
43.5 |
12.1 |
38 |
65 |
2900 |
7.5 |
3.0 |
80-250 |
50 |
13.9 |
80 |
59 |
2900 |
22 |
3.0 |
80-250A |
46.7 |
13.0 |
70 |
59 |
2900 |
18.5 |
3.0 |
80-250B |
43.3 |
12.0 |
60 |
58 |
2900 |
15 |
3.0 |
80-315 |
50 |
13.9 |
125 |
54 |
2900 |
37 |
3.0 |
80-315A |
46.5 |
12.9 |
110 |
54 |
2900 |
30 |
3.0 |
80-315B |
44.5 |
12.4 |
100 |
53 |
2900 |
30 |
3.0 |
80-315C |
41 |
11.4 |
85 |
51 |
2900 |
22 |
3.0 |
80-100(I) |
100 |
27.8 |
12.5 |
76 |
2900 |
5.5 |
4.5 |
80-100(I)A |
89 |
24.7 |
10 |
74 |
2900 |
4.0 |
4.5 |
80-125(I) |
100 |
27.8 |
20 |
76 |
2900 |
11 |
4.5 |
80-125(I)A |
89 |
24.7 |
16 |
74 |
2900 |
7.5 |
4.5 |
80-160(I) |
100 |
27.8 |
32 |
76 |
2900 |
15 |
4.5 |
80-160(I)A |
93.5 |
26.0 |
28 |
74 |
2900 |
11 |
4.5 |
80-160(I)B |
86.6 |
24.1 |
24 |
72 |
2900 |
11 |
4.5 |
80-200(I) |
100 |
27.8 |
50 |
74 |
2900 |
22 |
4.0 |
80-200(I)A |
93.5 |
26.0 |
44 |
73 |
2900 |
18.5 |
4.0 |
80-200(I)B |
87 |
24.2 |
38 |
71 |
2900 |
15 |
4.0 |
80-250(I) |
100 |
27.8 |
80 |
69 |
2900 |
37 |
4.0 |
80-250(I)A |
93.5 |
26.0 |
70 |
68 |
2900 |
30 |
4.0 |
80-250(I)B |
87 |
24.2 |
60 |
66 |
2900 |
30 |
4.0 |
80-315(I) |
100 |
27.8 |
125 |
66 |
2900 |
75 |
4.0 |
80-315(I)A |
95 |
26.4 |
113 |
66 |
2900 |
55 |
4.0 |
80-315(I)B |
90 |
25 |
101 |
65 |
2900 |
45 |
4.0 |
80-315(I)C |
82 |
22.8 |
85 |
63 |
2900 |
37 |
4.0 |
Pump model |
internet traffic |
lift |
efficiency |
rotational speed |
Motor Power |
Cavitation residue |
|
(m 3 /h) |
(l/s) |
||||||
100-100 |
100 |
27.8 |
12.5 |
76 |
2900 |
5.5 |
4.5 |
100-100A |
89 |
47 |
10 |
74 |
2900 |
4.0 |
4.5 |
100-125 |
100 |
27.8 |
20 |
76 |
2900 |
11 |
4.5 |
100-125A |
89 |
24.7 |
16 |
74 |
2900 |
7.5 |
4.5 |
100-160 |
100 |
27.8 |
32 |
76 |
2900 |
15 |
4.5 |
100-160A |
93.5 |
26.0 |
28 |
74 |
2900 |
11 |
4.5 |
100-160B |
86.5 |
24.1 |
24 |
72 |
2900 |
11 |
4.5 |
100-200 |
100 |
27.8 |
50 |
74 |
2900 |
22 |
4.0 |
100-200A |
93.5 |
26.0 |
44 |
73 |
2900 |
18.5 |
4.0 |
100-200B |
87 |
24.2 |
38 |
71 |
2900 |
15 |
4.0 |
100-250 |
100 |
27.8 |
80 |
69 |
2900 |
37 |
4.0 |
100-250A |
93.5 |
26.0 |
70 |
68 |
2900 |
30 |
4.0 |
100-250B |
87 |
24.2 |
60 |
66 |
2900 |
30 |
4.0 |
100-315 |
100 |
27.8 |
125 |
66 |
2900 |
75 |
4.0 |
100-315A |
95 |
26.4 |
113 |
66 |
2900 |
55 |
4.0 |
100-315B |
90 |
25.0 |
101 |
65 |
2900 |
45 |
4.0 |
100-315C |
82 |
22.8 |
85 |
63 |
2900 |
37 |
4.0 |
125-100 |
160 |
44.4 |
12.5 |
82 |
2900 |
11 |
4.0 |
125-100A |
143 |
39.7 |
10 |
77 |
2900 |
7.5 |
4.0 |
125-125 |
160 |
44.4 |
20 |
80 |
2900 |
15 |
4.0 |
125-125A |
143 |
39.7 |
16 |
77 |
2900 |
11 |
4.0 |
125-160 |
160 |
44.4 |
32 |
78 |
2900 |
22 |
4.0 |
125-160A |
150 |
41.7 |
28 |
76 |
2900 |
18.5 |
4.0 |
125-160B |
138 |
38.3 |
24 |
73 |
2900 |
15 |
4.0 |
125-200 |
160 |
44.4 |
50 |
77 |
2900 |
37 |
5.5 |
125-200A |
150 |
41.7 |
44 |
76 |
2900 |
30 |
5.5 |
125-200B |
138 |
38.3 |
37.5 |
75 |
2900 |
30 |
5.5 |
125-250 |
160 |
44.4 |
80 |
75 |
2900 |
55 |
5.0 |
125-250A |
150 |
41.7 |
70 |
74 |
2900 |
45 |
5.0 |
125-250B |
138 |
38.3 |
60 |
73 |
2900 |
37 |
5.0 |
125-315 |
160 |
44.7 |
125 |
70 |
2900 |
90 |
5.0 |
125-315A |
150 |
41.7 |
110 |
70 |
2900 |
75 |
5.0 |
125-315B |
143 |
39.7 |
100 |
69 |
2900 |
75 |
5.0 |
125-315C |
134 |
37.2 |
88 |
67 |
2900 |
55 |
5.0 |
150-200 |
200 |
55.6 |
12.5 |
78 |
1450 |
15 |
3.0 |
150-200A |
176 |
49.7 |
10 |
76 |
1450 |
11 |
3.0 |
150-250 |
200 |
55.6 |
20 |
79 |
1450 |
18.5 |
3.0 |
150-250A |
184.4 |
51.2 |
17 |
78 |
1450 |
15 |
3.0 |
150-250B |
167 |
46.4 |
14 |
76 |
1450 |
11 |
3.0 |
150-315 |
200 |
55.6 |
32 |
78 |
1450 |
30 |
3.5 |
150-315A |
187 |
51.9 |
28 |
77 |
1450 |
22 |
3.5 |
150-315B |
173 |
48.1 |
24 |
76 |
1450 |
18.5 |
3.5 |
150-400 |
200 |
55.6 |
50 |
75 |
1450 |
45 |
3.5 |
150-400A |
187 |
51.9 |
44 |
74 |
1450 |
37 |
3.5 |
150-400B |
174 |
48.3 |
38 |
73 |
1450 |
30 |
3.5 |
150-400V |
160 |
44.4 |
32 |
71 |
1450 |
22 |
3.5 |
150-250(I) |
200 |
55.6 |
80 |
76 |
2900 |
75 |
4.5 |
150-250(I)A |
187 |
51.9 |
70 |
75 |
2900 |
55 |
4.5 |
150-250(I)B |
173 |
48.1 |
60 |
74 |
2900 |
45 |
4.5 |
150-315(I) |
200 |
55.6 |
125 |
73 |
2900 |
111 |
4.5 |
150-315(I)A |
187 |
51.9 |
110 |
72 |
2900 |
90 |
4.5 |
150-315(I)B |
173 |
48.1 |
95 |
70 |
2900 |
75 |
4. |
Knowledge of using horizontal pipeline centrifugal oil pump:
Preparation before startup
1. Test whether the motor rotation is correct. When viewed from the top of the motor towards the pump, it rotates clockwise. The test time should be short to avoid causing mechanical tightness
Seal and wear.
2. Open the exhaust valve to fill the entire pump body with liquid, and then close the exhaust valve when it is full.
3. Check if all parts are normal.
4. Manually rotate the pump to allow lubricant to enter the mechanical seal end face.
5. High temperature type should be preheated first, with a heating rate of 50 ℃/hour to ensure uniform heating of all parts.
start:
1. Fully open the inlet valve.
2. Close the valve of the discharge pipeline.
3. Start the motor and observe if the pump is running correctly.
4. Adjust the opening of the outlet valve to the desired operating conditions. If the user has a flow meter or pressure gauge installed at the pump outlet, the outlet should be adjusted by adjusting it
The valve opening allows the pump to operate at the rated point listed in the performance parameter table. If the user has a flow or pressure gauge installed at the pump outlet, it should
By adjusting the opening of the outlet valve and measuring the motor current of the pump, the motor can operate within the rated current, otherwise it will cause the pump to overload
Run (i.e. high current operation) until the motor burns out. The opening size of the outlet valve that is adjusted correctly is related to the working conditions of the pipeline.
5. Check the leakage of the shaft seal. Normally, the mechanical seal leakage should be less than 3 drops per minute.
6. Check that the temperature rise at the motor and bearings is ≤ 70 ℃.
parking
1. The high-temperature type should first cool down, with a cooling rate of less than 10 ℃/minute, and then lower the temperature to below 80 ℃ before parking.
2. Close the valve of the discharge pipeline.
3. Stop the motor.
4. Close the inlet valve.
5. If parking for a long time, the liquid in the pump should be drained completely.
Installation Instructions for ISWHB Stainless Steel Horizontal Centrifugal Oil Pump
1. Before installation, check if the fasteners of the unit are loose and if there are any foreign objects blocking the flow channel of the pump body to avoid damaging the blades during the operation of the water pump
Wheel and pump body.
2. The weight of the pipeline should not be added to the water pump during installation to avoid deformation of the pump.
3. The foundation bolts must be tightened during installation to avoid the impact of vibration on pump performance during start-up.
4. For the convenience of maintenance and safety of use, install one regulating valve on each inlet and outlet pipeline of the pump, and install one near the pump outlet
Only pressure gauges are used to ensure operation within the rated head and flow range, ensuring the normal operation of the pump and increasing its service life.
5. After installation, the pump shaft should be moved, and there should be no friction sound or jamming phenomenon of the impeller. Otherwise, the pump should be disassembled to check the cause.
6. There are two types of pump installation: rigid connection installation and flexible connection installation (see connection method).
Fault analysis of ISWHB stainless steel horizontal centrifugal oil pump:
failure mode |
cause |
Troubleshooting |
The pump is not producing water |
a. The import and export valves are not open, the inlet and outlet pipelines are blocked, and the impeller of the flow channel is blocked |
Check and remove blockages |
b. The motor is running in the wrong direction and has a slow speed due to phase loss |
Adjust the direction of the motor and tighten the motor wiring |
|
c. Leakage of suction pipe |
Tighten all sealing surfaces and eliminate air |
|
d. The pump is not filled with liquid and there is air inside the pump chamber |
Open the pump cover or open the exhaust valve to exhaust all the air |
|
e. Insufficient imported water supply, high suction, and bottom valve leakage |
Shutdown inspection and adjustment (this phenomenon is prone to occur when using grid connected water pipes and suction pumps) |
|
f. Excessive pipeline resistance and improper pump selection |
Reduce pipeline bends and reselect pumps |
|
Insufficient water pump flow |
a. First, check the reason according to 1 |
First, press 1. Exclude |
b. Partial blockage of pipeline and pump impeller, deposition of scale, and insufficient valve opening |
Remove the obstruction and readjust the valve opening |
|
c. Low voltage |
voltage stabilization |
|
d. Impeller wear |
Replace the impeller |
|
Excessive power |
a. Exceeding the rated flow usage |
Adjust the flow rate and turn down the outlet valve |
b. High suction distance |
reduce |
|
c. Pump bearing wear |
Replace bearings |
|
Noise vibration |
a. Unstable pipeline support |
Stable pipeline |
b. Liquid mixed with gas |
Increase suction pressure and exhaust |
|
c. Generate cavitation |
Reduce the vacuum degree |
|
d. Bearing damage |
Replace bearings |
|
e. Motor overload and heating operation |
Adjust according to 5 |
|
Motor overheating |
a. Excessive traffic and overloaded operation |
Turn down the outlet valve |
b. Rubbing and rubbing |
Check and exclude |
|
c. Motor bearings damaged |
Replace bearings |
|
d. Insufficient voltage |
voltage stabilization |
|
Water pump leakage |
a. Mechanical seal wear |
replace |
b. The pump body has sand holes or cracks |
Welding repair or replacement |
|
c. Uneven sealing surface |
trim |
|
d. Loosening of installation bolts |
fastening |
Please provide as much as possible for ordering:
1. Model 2. Diameter 3. Head (m) 4. Flow rate 5. Motor power (KW) 6. Speed (R/mi)n) 7. Material8. Voltage(V)
Welcome to visit our Quanda Pump Valve【www.quandabf.cn】If you have any questionsYou can callGive it to meWe will do our best to provide you with high-quality service.