HTY-KS2000 Lithium Battery Pole Plate Kjeldahl Furnace Trace Moisture Analyzer
The Hengteya brand HTY-KS2000 lithium battery pole piece Kjeldahl furnace trace moisture analyzer adopts a Karl Fischer moisture analyzer equipped wit
Product details



Hengteya brandHTY-KS2000 Lithium Battery Pole Plate Kjeldahl Furnace Trace Moisture AnalyzerUsing a Karl Fischer moisture analyzer equipped with a Karl Fischer headspace sampler, connected by a professional insulated pipeline, it can achieve carrier gas input and water vapor output. Place the sample bottle loaded with the sample into a Karl Fischer oven, evaporate the water by heating, and blow the water vapor into the reaction cup of the Karl Fischer moisture analyzer with nitrogen gas to react with the Karl Fischer reagent and detect the moisture content of the sample. This method is suitable for samples with low moisture content and cannot be directly detected using the Karl Fischer method.
Hengteya brand HTY-KS2000Lithium battery electrode plate Karl Fischer furnace micro moisture analyzerThe moisture meter is a high-precision micro moisture meter with a touch screen and a large navigation interface. It is easy to operate and has a testing accuracy of up to 1ppm. It has multiple built-in calculation formulas to meet different testing needs. The built-in micro printer can print test data at any time. Hengteya's instrument can meet the high precision requirements of various factories and laboratories for moisture. It has been widely used in departments such as lithium batteries, plastics, polymer materials, and scientific research. It is a fully automatic and intelligent moisture analyzer.

Hengteya brandHTY-KS2000Lithium battery electrode plate Karl Fischer furnace micro moisture analyzerTechnical parameters:
Model: | HTY-KS2000 |
Display mode: | Color LCD touch screen display |
Measurement method: | Karl Fischer coulometric titration+Karl Fischer headspace sampler |
Measurement range: | 3 micrograms of water -200 milligrams of water |
resolving power: | 0.1ug water |
Water content range: | 0.0001%(1ppm)— 100% |
Accuracy: |
When the water content is between 3 micrograms of water and 100 micrograms of water, the error is ≤± 3ug, When the water content is above 100 micrograms of water, the error is ≤± 0.3% (excluding injection error) |
Electrolysis speed: | ≤ 2.24mg water/min |
Electrolytic current: | 0-400mAh |
Endpoint indication: | Screen display/sound warning/print output/endpoint light prompt |
Blank processing: | The blank current microprocessor automatically controls compensation to ensure accurate deduction of blank during the 10 minute sample enrichment time |
Drift compensation: | The microprocessor automatically calculates and compensates |
Calculation formula: | Built in 8 calculation formulas |
Data input: | Touch screen operation input |
Temperature accuracy: | 1℃ |
Heating rate: | 30 ℃/min (room temperature -300 ℃, 220V) |
Delayed titration: | 0-9999 seconds |
Sample method: | 5 independent methods |
Flow range: | 0—160ml/min |
Sample bottle specifications: | 10ml (5ml, 20ml optional) |
Printing function: | Built in embedded thermal printer, ready to print anytime |
Print content: | Ug/ppm/mg/L/sample number/experimenter/date |
Mixing method: | Electromagnetic stirring |
Mixing system: | Manual adjustment, infinitely variable speed |
Electrode material: | High purity platinum electrode |
Self checking function: | The internal microprocessor function of the instrument automatically detects instrument faults |
Calendar/Clock: | Analyze time and date display (without losing power) |
Usage environment: | Temperature 0-40 ℃, humidity<85% |
Using power supply: | Voltage 220V ± 10%, frequency 50HZ ± 2.5HZ |

Hengteya brand HTY-KS2000Lithium battery electrode plate Karl Fischer furnace micro moisture analyzerScope of application:
liquid |
Pharmaceutical industry: raw materials for traditional Chinese and Western medicine, etc Pesticide industry: soluble powders, emulsions, emulsions, creams, pastes, oils, etc Petroleum and power industry: insulation oil, transformer oil, hydraulic oil, coal tar, etc Chemical industry: acids, alcohols, benzenes, phenols, ethers, organic solvents, etc Other industries: lithium batteries, electrolytes, cosmetics, etc |
solid | All dissolved and insoluble solids such as lithium battery electrodes, lithium battery raw materials, etc |
gas | Natural gas, liquefied gas, fluorocarbons, butadiene and other gases |

Hengteya brandHTY-KS2000Lithium battery electrode plate Karl Fischer furnace micro moisture analyzerProduct specifications:
1. GB/T 6283-2008 Determination of moisture content in chemical products Karl Fischer method
2. ASTM E1064-2008 Karl Fischer Coulombic Titration for Determination of Water Content in Organic Liquids
3. GB/T 7600-1987 Determination of Moisture Content in Operating Transformer Oil (Coulombic Method)
4. ASTM D4928-00 (2010) Karl Fischer Coulombic Titration for Determination of Water Content in Crude Oil
5. ASTM D6304-2007 Karl Fischer coulometric titration method for determining water content in petroleum products, lubricants, and additives
6. ISO 10337-1997 Determination of Moisture in Crude Oil Karl Fischer Coulombic Titration Method
7. GB/T 11146-2009 Determination of Crude Oil Water Content Karl Fischer Coulombic Titration Method
8. GB/T 3727-2003 Determination of Trace Water in Ethylene and Propylene for Industrial Use
9. GB/T 5074-1985 Method for determination of moisture content in coking products by microcoulometry
10. GB/T 6023-2008 Determination of Trace Water in Butadiene for Industrial Use Karl Fischer Coulombic Method
11. GB/T 7376-2008 Determination of Trace Moisture in Fluoroalkanes for Industrial Use Karl Fischer Method
12. GB/T 18619.1-2002 Determination of Water Content in Natural Gas Karl Fischer Coulombic Method
13. SH/T 0246-1992 Determination of Water Content in Light Petroleum Products (Electricity Method)
14. SH/T 0255-1992 Method for determination of moisture content in additives and lubricating oils containing additives (electric method)
15. ASTM E1064-2008 Karl Fischer Coulombic Titration for Determination of Water Content in Organic Liquids
16. ASTM D4928-00 (2010) Karl Fischer Coulombic Titration for Determination of Water Content in Crude Oil
17. ASTM D6304-2007 Standard for Determination of Water Content in Petroleum Products, Lubricants, and Additives by Karl Fischer Coulombic Titration

Hengteya brandHTY-KS2000Lithium battery electrode plate Karl Fischer furnace micro moisture analyzerFunctional features:
1. Chinese touch screen navigation system, operation instructions, easy to use, real-time display of current working status;
2. By using a high-precision Coulomb method moisture analyzer in conjunction with a Karl Fischer furnace, it can detect 3 μ g of water with an accuracy of ppm level. Various insoluble solids can also be easily detected;
3. High precision temperature controller and PT100 thermistor ensure the accuracy of temperature control precision;
4. The temperature can reach 300 ℃ to meet most sample testing requirements, and the airflow can be adjusted from 0-100ml, suitable for samples with various water release rates;
5. Hollow core gas needle injection, gas delivery pipeline with heating function, zero dead volume water vapor, heated and insulated gas delivery pipeline can effectively prevent the gas in the sample bottle from condensing during transmission, making the operation simpler and facilitating the replacement of the sample bottle;
6. There are 5 built-in methods to choose from, 8 calculation formulas for convenient sample testing, and customized sample units such as%, ppm, mg/kg, etc., making the result units more user-friendly;
7. Easy to operate, users only need to set the appropriate temperature and flow rate, put the sample into the pre prepared sample bottle, put it into the heater, and then insert the transfer needle into the silicone pad of the sample bottle. Click on the instrument to start measuring;
8. Using headspace injection method to ensure that each measurement uses a "new" sample bottle and there is no cross infection in the sample measurement. The sample bottle has a small volume, ensuring a small dead volume and background moisture value. The independent sealed sample bottle does not require sample transfer during measurement, resulting in more accurate results. The screw cap sample bottle does not require specialized and expensive capping and opening devices, making it very convenient to use. Headspace sampling technology allows only gas to enter the reaction cup of the moisture analyzer without contaminating the reaction cup and electrolysis electrode;
9. The blank current microprocessor automatically controls compensation to ensure that the reagent is always in a balanced state;
10. The instrument has a self checking function, and if there is a malfunction, it will automatically prompt.

Hengteya brandHTY-KS2000Lithium battery electrode plate Karl Fischer furnace micro moisture analyzerOperation steps:
1. After installing the instrument accessories according to the instructions, turn on the instrument;
2. Set the parameters according to the instructions, select the appropriate temperature and flow rate;
3. Put the sample into the sample bottle, put it into the Karl Fischer oven, and insert the transfer needle into the inlet of the Karl Fischer moisture analyzer;
4. Sample determination. After pressing the start button to inject the sample, the instrument will automatically perform the test. After the test is completed, a beep alarm will sound and the display screen will indicate "Test completed".

Hengteya brandHTY-KS2000Lithium battery electrode plate Karl Fischer furnace micro moisture analyzerprecautions:
1、 Cannot display normally
Please check if the power connection wire, fuse, and power switch of the instrument are functioning properly.
2、 The instrument displays iodine
1. Evaluate whether the reagent is over iodine. If so, use a 0.5 microliter sampler to extract 0.2-0.4 microliters of water and inject it. Do not use an injector of 50 microliters or larger for injection.
2. Check whether the platinum wire at the bottom of the measuring electrode is connected together, causing a short circuit.
3、 The instrument shows an open circuit
Check if the measuring electrode is in good contact and re insert it firmly. Check if the connecting wire is broken.
4、 Open electrolysis without counting
Check if the electrolytic electrode is in good contact, unplug and plug it again, and check if the connecting wire is broken.
5、 Electrolysis does not end
Check if the reagent has expired.

Enjoy a one-year free warranty and lifetime maintenance from the date of purchase;
7-day no reason return and exchange, 24-hour instant response;
One on one technical guidance, allowing you to have no worries after purchasing;