Applicable industriesThe electric trace index tester is suitable for research, production, and quality inspection departments of lighting equipment, low-voltage electrical appliances, household appliances, machine tool appliances, motors, power tools, electronic instruments, electrical instruments, and information technology equipment. It is also suitable for industries such as insulation materials, engineering plastics, electrical connectors, and accessories.
Test method: On the surface of a solid insulation material, a certain voltage is applied between platinum electrodes of a specified size (2mm × 5mm), and a specified droplet volume of contaminated liquid (0.1% NH 4 CL) is dropped at a fixed time (30s) and height (35mm) to evaluate the tolerance of the solid insulation material surface under the combined action of electric field and contaminated medium. The relative tracking index (CT1) and tracking resistance index (PT1) are measured
Applicable standards: IEC6012:2003, GB4706.1, and GB/T5169.4 GB2099.1、VDE、 The simulation test items specified in the standards for the determination method of the electrical trace resistance index and the comparative electrical trace index of solid insulation materials.
Main parameters and technical indicators
1. Electrode material: Test electrode - platinum, electrode rod - copper (platinum purity meets the standard requirement of 99%)
2. Electrode size: (2mm ± 0.1mm) × (5mm ± 0.1mm) × (40mm ± 5mm)
3. Platinum electrode 12mm, inclined at 30 °± 2 °
4. Electrode distance: 4.0mm ± 0.01mm, angle 60 °± 5 °
5. Electrode pressure: 1.00N ± 0.01N
6. Test solution resistance: A solution 0.1% NH4Cl, 3.95 ± 0.05 Ω m; B liquid 1.98 ± 0.05 Ω m
7. Dropping device: No adjustment required during testing, simple operation
8. Drop height: 35mm ± 5mm (adjustable)
9. Droplet time: 30s ± 0.01s (better than standard) (adjustable by preset)
50 drops time 24.5 minutes ± 2 minutes
Droplet count: 1~9999 (pre-set) (droplet size can be adjusted to make the capacity of 44-55 droplets 1cm3)
10.)
11. Test wind speed: 0.2m/s (new standard)
12. Test voltage: 100V~600V (25V division, adjustable)
13. Power voltage drop: 8% at 1.0A ± 0.1A
14. Traceability assessment: 0.50A ± 10%, 2.00s±10%
15. The voltage can be adjusted between 100-600V (48-60Hz), and the voltage drop should not exceed 10% when the short-circuit current is 1.0 ± 0.0001A (better than the standard 0.1A);
16. Exhaust hole: Ø 100mm
17. Air environment: Temperature 0~40 ℃ Relative humidity: ≤ 80% Places without obvious vibration and corrosive gases
When the short-circuit current is greater than 0.5A in the test circuit, the relay will operate for 2 seconds to cut off the current and indicate that the test sample is unqualified;
19. Test power supply: 220V 0.6kVA 50-60Hz
20. Dimensions: Width 1160mm, Depth 600mm, Height 1310 (including feet) mm
21. Combustion test area volume:>0.5 cubic meters, length * width * height approximately 900mm × 590mm × 1050mm, background black, background illumination ≤ 20Lux