Beijing Huakeyi Technology Co., Ltd
Home>Products>HK-8080 residual chlorine analyzer
HK-8080 residual chlorine analyzer
HK-8080 residual chlorine analyzer
Product details
HK-8080 residual chlorine analyzerUsing an electrochemical technique, real-time online monitoring of residual chlorine is achieved by measuring the relationship between the current changes caused by chemical reactions on the electrode and the concentration of the analyte. Can simultaneously meet the requirements of residual chlorine HClO、 Online monitoring of temperature and pH parameters. Suitable for online monitoring of residual chlorine in tap water, pipeline water, water treatment disinfection, and wastewater treatment environments.

Optional pH automatic and manual compensation

Unique temperature compensation method, eliminating the influence of temperature on measurement results

Realize residual chlorine HClO、 Simultaneous monitoring of temperature and pH parameters

No reagents, electrochemical measurement method

Flow pool with manual sampling, convenient and fast manual sampling

No need to replace reagents, real-time online monitoring

SD card can be used for on-site upgrades or data retrieval

Measurement range:

Residual chlorine: 0.0020.00mg/L

HOCl 0.0010.00mg/L

pH 0.0014.00

Temperature: 0.050.0

resolving power:

Residual chlorine:0.01mg/L

HOCl0.01 mg/L

pH 0.01

Temperature: 0.1

Accuracy:

Residual chlorine: be better than±2%or±0.02mg/LTake the larger one

HOCl be better than±2%or±0.02mg/LTake the larger one

pH±0.05

Temperature:±0.5

Minimum detection limit:

0.01mg/L

Response time: (T90

≤90s

Calibration method:

Laboratory comparison method

pHCompensation method:

Manual/automatic

Temperature compensation method:

Manual/automatic

Sample water conditions:

Temperature range: (550

Water sample flow rate:3040 L/h

water samplepHRange:49

The water sample is allowed to have a solid composition of:≤5μm(No gelatinous substances allowed, no grease)

Output current:

020mAOr(420mA(Two isolated outputs)

Output current accuracy:

±0.1mA

Maximum load resistance:

800Ω20mA max.

Environmental requirements:

Environmental temperature: (545

ambient humidity:≤90%(No condensation)

Power supply:

AC(100240)V, (5060)Hz

Storage and transportation temperature:

-2055(Excluding electrodes, electrodes should be higher than0

through News:

Internal communication within the factory (no wiring required by users);

Optional:

RS485Communication orProfibusCommunication (only one option can be chosen)Hartcommunication

Alarm output:

Dual normally open programmable relay contacts:DC 5A/30VorAC 5A/250V

1 host

1 set of residual chlorine analyzer flow tank

One online triple composite pH electrode

1 residual chlorine electrode

One online residual chlorine electrode cable

One HK-328 electrode cable

Special electrolyte for residual chlorine electrode

1 bottle

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!