Gravity based hydraulic automation water treatment machine
National Patent Number: eight

(1) The daily operating cost of a water treatment system is one-third to one-fifth of that of a conventional sand tank system.
(2) The equipment performance is safe and reliable, integrating physical, biological, and chemical methods. No secondary pollution.
(3) Hydraulic automation equipment does not require operation or maintenance, has simple management, and does not have dedicated personnel.
(4) The unique dual aeration and oxygenation technology activates the water with oxygen, effectively preventing black and odorous water and removing organic pollution from the water.
(5) 7-layer fine mineral filter layer, with clear and transparent effluent, superior to relevant national standards.
(6) The device has a compact structure and occupies a small area.
(7) No need to replace filter media or lining. UPVC water supply material, non corrosive, main equipment warranty of 30 years.
(8) Hydraulic automatic backwashing, automatic stop, no manual operation required. Rinse for 3 minutes.
(9) National patents, high-tech products leading the international level, with comprehensive advantages.
-
Small river water purification, landscaping, and water quality maintenance
(Natural rivers, landscape rivers, artificial rivers, landscape creeks, landscape waterfalls, etc.) -
Small lakes for water purification, landscaping, and water quality maintenance
(Natural lakes, scenic water areas, park lakes, artificial lakes, water storage tanks, ponds, etc.) -
Landscape water bodies and fountain water bodies within large hydrophilic communities
(Landscape water circulation, water quality freshness, closeness to nature, elimination of water pollution) - Purification of precious fish watching water bodies and artificial aquaculture pond water
(Aeration and oxygenation to increase aquaculture density and improve the living environment of aquatic organisms)
1、 Aeration dissolved oxygen eliminates black and odorous phenomena in water bodies
The water enters the water treatment equipment through a circulating pump for sufficient aeration and dissolved oxygen. Through the mixing of gas and water, the coagulation effect of pollutants in the pool water can be enhanced, which is beneficial for the effective interception of pollutants by the next step of the filtration medium. Water bodies need to undergo two rounds of aeration in a single water treatment project. Increasing the dissolved oxygen content in water can effectively prevent the phenomenon of black and odorous water. Because with the proliferation of algae, a large amount of oxygen is consumed in the water, causing aerobic bacteria to die and anaerobic bacteria to multiply, the black and odorous phenomenon is the result of fermentation. According to water quality testing, the dissolved oxygen in the treated water remains saturated, making the water always fresh and activated.
2、 Fine filtration to reduce turbidity
During the filtration process, the main functions are interception and adsorption. The equipment uses multiple layers of composite anti filtration layers composed of different mineral materials from large to small, greatly enhancing the interception and filtration effect. At the same time, a thin biofilm is formed on the surface of the filtration medium, which can further adsorb organic and inorganic substances in the water. The minimum particle diameter of the filter medium is 0.15 millimeters, with extremely strong interception ability and excellent effluent quality.
3、 Nitrogen and phosphorus removal function
The increase of nitrogen and phosphorus in water bodies enables algae and other organisms to obtain abundant nutrients and reproduce in large quantities, resulting in eutrophication of the water body. Foam is produced in water body by mixing air and water, and foam is composed of organic matter such as nitrogen, phosphorus and grease. In the water treatment equipment, when the raw water mixed with foam comes to the filter layer, the foam floats on the water surface and cannot pass through the filter layer. When foam accumulates, it overflows through the pipeline, or when backwashing, foam is washed away with one piece. Thus, continuous cyclic treatment is carried out to gradually remove nitrogen, phosphorus, and other elements that cause eutrophication in the water.
4、 Fully automated operation and backwashing
Backwashing is entirely determined by the working condition of the filter layer in the filter, rather than the unscientific practice of regular backwashing in traditional processes. Due to the continuous interception of suspended solids in the incoming water by the filter layer, the filter layer becomes clogged and the water level rises, resulting in siphon phenomenon. At this time, the filter layer undergoes strong backwashing. After the filter layer is washed clean, the backwash is completed. During flushing, it does not affect the operation of the equipment. The entire system does not require dedicated personnel to manage, part-time work is sufficient. Simply press the water pump start button to start the system, and turn off the system by disconnecting the water pump button.
5、 Advanced algae killing and sterilization system
Algae in water reproduce rapidly under photosynthesis. The proliferation and death of algae cause black and odorous water bodies. Continuous algae removal is required, which has been treatedAlgae can be removed from water bodies, but they will reproduce in large numbers afterwards.
Advanced configurationUltraviolet Water Purifier
Total water volume (m3)/cycle period (h)=hourly processing water volume (m3/h), then refer to the table to determine the model and obtain the dimensions of each part of the model.
Water volume table for hydraulic automation equipment processing
model |
Water treatment capacity |
Total pool capacity of swimming pool, recreational pool, and water park (m3) |
Total storage capacity of lake water and landscape water (m3) |
||||
Cycle period |
Cycle period |
||||||
6h |
8h |
10h |
12h |
48h |
72h |
||
SW-1300 |
18~25 |
100~150 |
150~200 |
180~250 |
200~300 |
800~1200 |
1200~1800 |
SW-1700 |
40~56 |
240~330 |
320~440 |
400~560 |
480~670 |
1900~2600 |
2800~4000 |
SW-2200 |
70~100 |
420~600 |
560~800 |
700~1000 |
800~1200 |
3300~4800 |
5000~7200 |
SW-2600 |
110~160 |
660~960 |
880~1200 |
1100~1600 |
1300~1900 |
5200~7600 |
7900~11500 |
SW-3000 |
160~230 |
960~1300 |
1280~1800 |
1600~2300 |
1900~2700 |
7600~11000 |
11500~16500 |
SW-3400 |
220~300 |
1300~1800 |
1700~2400 |
2200~3000 |
2600~3600 |
10000~14400 |
15800~21600 |
SW-4000 |
280~400 |
1600~2400 |
2200~3200 |
2800~4000 |
3300~4800 |
13400~19000 |
20000~28800 |
SW-4400 |
360~510 |
2000~3000 |
2800~4000 |
3600~5100 |
4300~6000 |
17000~24000 |
25900~36700 |
SW-4800 |
440~630 |
2600~3700 |
3500~5000 |
4400~6300 |
5200~7500 |
21000~30000 |
31600~45000 |
SW-5400 |
540~760 |
3000~4500 |
4300~6000 |
5400~7600 |
6400~9000 |
25000~36000 |
38000~54000 |
SW-5800 |
640~900 |
3800~5400 |
5000~7200 |
6400~9000 |
7600~10000 |
30000~43000 |
46000~64000 |
SW-6200 |
740~1000 |
4400~6000 |
5900~8000 |
7400~10000 |
8800~12000 |
35000~48000 |
53000~72000 |
SW-6500 |
860~1200 |
5000~7200 |
6800~9600 |
8600~12000 |
10000~14000 |
41000~57000 |
60000~86000 |
SW-7000 |
1000~1400 |
6000~8400 |
8000~11000 |
10000~14000 |
12000~16800 |
48000~67000 |
72000~100000 |
SW-7400 |
1140~1600 |
6800~9600 |
9000~12800 |
11400~16000 |
13000~19000 |
54000~76000 |
82000~115000 |
explain:
1. The circulation cycle of the swimming pool is determined according to the requirements of Party A and the level (importance) of the pool. It is predicted that for pools with high pedestrian flow in the future, the circulation cycle should be shortened and the lower limit of the water treatment capacity should be taken. Conversely, the cycle can be extended and the upper limit of the water treatment capacity should be taken.
2. The treatment of lake water requires a high water quality and a clear cycle of no more than 24 hours. For visibility requirements of 1.2-1.5m, take 24-48h; for visibility requirements of 0.5-0.8m, take 48-72h. After 72h, the water quality cannot be guaranteed.
Model and Size Table of Hydraulic Automation Water Treatment Machine
model |
Processing water volume m3/h |
Equipment size mm |
Height mm |
Inlet pipe diameter mm |
Diameter of outlet pipe mm |
Diameter of sewage pipe mm |
Net height of computer room mm |
SW-1300 |
18~25 |
1300×1300 |
3400 |
75~100 |
75~100 |
150 |
4500 |
SW-1700 |
40~56 |
1700×1700 |
3400 |
100~150 |
100~150 |
200 |
4500 |
SW-2200 |
70~100 |
2200×2200 |
4000 |
150~200 |
150~200 |
200 |
4500 |
SW-2600 |
110~160 |
2600×2600 |
4400 |
200~250 |
200~250 |
250 |
5000 |
SW-3000 |
160~230 |
3000×3000 |
4400 |
200~250 |
200~250 |
300 |
5000 |
SW-3400 |
220~300 |
3400×3400 |
4400 |
200~300 |
200~300 |
300 |
5000 |
SW-4000 |
280~400 |
4000×4000 |
4400 |
250~350 |
250~350 |
400 |
5000 |
SW-4400 |
360~510 |
4400×4400 |
4400 |
250~400 |
250~400 |
400 |
5000 |
SW-4800 |
440~630 |
4800×4800 |
4700 |
300~500 |
300~500 |
500 |
>5000 |
SW-5400 |
540~760 |
5400×5400 |
4700 |
350~500 |
350~500 |
500 |
>5000 |
SW-5800 |
640~900 |
5800×5800 |
4700 |
400~500 |
400~500 |
600 |
>5000 |
SW-6200 |
740~1000 |
6200×6200 |
4700 |
400~600 |
400~600 |
600 |
>5000 |
SW-6500 |
860~1200 |
6500×6500 |
4700 |
400~600 |
400~600 |
700 |
>5000 |
SW-7000 |
1000~1400 |
7000×7000 |
4700 |
400~600 |
400~600 |
700 |
>5000 |
SW-7400 |
1140~1600 |
7400×7400 |
4700 |
400~700 |
400~700 |
800 |
>5000 |
SW-800(I) |
20~40 |
Φ800 |
1500 |
75~100 |
75~100 |
150 |
1800 |
SW-1000(I) |
20~40 |
1000×1000 |
2200 |
100~150 |
100~150 |
150 |
2500 |
SW-1200(I) |
40~70 |
1200×1200 |
2700 |
150~200 |
150~200 |
200 |
3000 |
SW-1400(I) |
70~100 |
1400×1400 |
2700 |
200~250 |
200~250 |
200 |
3000 |
SW-1600(I) |
100~130 |
1600×1600 |
2700 |
250~300 |
250~300 |
250 |
3000 |
Note:The inlet pipe, return pipe and other pipelines can be connected freely within 360 ° of the plane, while the discharge pipe can only be connected within 360 ° of the bottom of the equipment. It is best to drain vertically downwards from the center of the machine.