Gravity based hydraulic automated swimming pool water treatment equipment
National Patent Number: eight

(1) Save 80% water, 80% electricity, 50-80% medicine, 90% manpower, and 50% civil engineering.
(2) No coagulants or algae suppressants are added to the pool water. No need to change the water, the pool water is sky blue and transparent, with an eternal standard.
(3) Hydraulic automation equipment does not require operation or maintenance, has simple management, and does not have dedicated personnel.
(4) The unique dual aeration and oxygenation technology activates the oxygen content in the pool water, effectively removing organic pollutants such as urea from the water.
(5) 7-layer fine mineral filter layer, with a effluent turbidity of 0.4NTU, better than the national standard.
(6) The device has a compact structure and occupies a small area.
(7) No need to replace filter media or lining. UPVC water supply material, non corrosive, main equipment warranty of 40 years.
(8) Hydraulic automatic backwashing, automatic stop, no manual operation required. Rinse for 3 minutes.
(9) National patents, high-tech products leading the international level, with comprehensive advantages.
Various swimming pools, water parks, seawater swimming pools, and large aquariums for circulating water purification
1、 Aeration and oxygen melting for urea removal
The pool water enters the equipment for sufficient aeration and dissolved oxygen. While oxygen is introduced, harmful gases such as ammonia and nitrogen (components of urea) are released, which are mixed with gas and water to enhance the coagulation and filtration effect of pollutants in the water. During a water treatment process, the pool water needs to undergo two rounds of aeration to increase the dissolved oxygen content in the water, enhance its ability to kill bacteria and inhibit bacterial growth, and remove organic pollutants such as urea from the water. The urea content in the treated water can reach about 1mg/l, without the need to dilute the urea content with water, saving a lot of water. The pool water is not only purified, but also fresher and activated, making it always clear to the bottom and creating a virtuous cycle.
2、 Low turbidity in fine filtration
During the filtration process, the main functions are interception and adsorption. The equipment uses multiple layers of composite anti filtration layers composed of different mineral materials from large to small, greatly enhancing the interception and filtration effect. At the same time, a film is formed on the surface of the filtration medium, which can further adsorb organic and inorganic substances in the water. The minimum particle diameter of the filter medium is 0.15 millimeters, much smaller than traditional quartz sand filter media, with extremely strong interception ability and excellent effluent quality. The effluent turbidity can reach 0.4 milligrams per liter, and the pool water is sky blue and transparent, far lower than the turbidity of tap water of 3 milligrams per liter.
3、 No coagulant or algaecide added
The traditional sand tank system requires the addition of coagulants and algaecides (CuSO4) to the water, which leads to an increasing concentration of residual ions in the water. It is necessary to frequently change the water to dilute the ion concentration, resulting in a significant waste of water. The use of hydraulic automation water treatment system prohibits the use of coagulants and algaecides, effectively avoiding the problem of chemical pollution in water. After system processing, the pool water can be used continuously without the need for daily water changes. Only a small amount of water taken away by the human body, evaporated from the pool surface, and backwashed by equipment needs to be replenished, and the water quality meets the standard all the time. It saves a lot of water, reduces daily operating costs, and can save up to 80% on water bills.
4、 Fully automated operation and backwashing
Backwashing is entirely determined by the working condition of the filter layer in the filter, rather than the unscientific practice of regular backwashing in traditional processes. Due to the continuous interception of suspended solids in the incoming water by the filter layer, the filter layer becomes clogged and the water level rises, resulting in siphon phenomenon. At this time, the filter layer undergoes strong backwashing. After the filter layer is washed clean, the backwash is completed. During flushing, it does not affect the operation of the equipment. The entire system does not require dedicated personnel to manage, part-time work is sufficient. Simply press the water pump start button to start the system, and turn off the system by disconnecting the water pump button.
5、 Water, electricity, and energy conservation
The main water quality issues are bacterial, algal, and urea pollution brought in by the human body. The main purpose of changing water is to dilute the pollution content. According to national regulations, multi-functional pools, amusement pools, public swimming pools, and pressure systems such as sand tank products are required to treat pool water. Indoor pools need to replace 5% -10% of the pool water every day, while outdoor pools need to replace 10% -15%. This greatly increases the daily water consumption of the pool and increases operating costs.
By adopting a gravity based hydraulic automated circulating water treatment system, this problem can be avoided and daily operating costs can be significantly reduced. The water treatment system is a gravity free system that requires a small pump head, only 7 meters, effectively saving electricity costs. Electricity bills can be saved by 80%.
6、 The equipment adopts new materials and has a long service life 40 years
All water inlets, return outlets, pipelines, valves, and water treatment equipment are made of white UPVC material for water supply, which is white, beautiful, generous, and corrosion-resistant. The system has no vulnerable parts, no corrosion, and does not require maintenance. Fundamentally solved the problem of rust water and the need for regular maintenance every year. The service life of water treatment systems can reach forty years.
Total water volume (m3)/cycle period (h)=hourly processing water volume (m3/h), then refer to the table to determine the model and obtain the dimensions of each part of the model.
Water volume table for hydraulic automation equipment processing
model |
Water treatment capacity |
Total pool capacity of swimming pool, recreational pool, and water park (m3) |
Total storage capacity of lake water and landscape water (m3) |
||||
Cycle period |
Cycle period |
||||||
6h |
8h |
10h |
12h |
48h |
72h |
||
SW-1300 |
18~25 |
100~150 |
150~200 |
180~250 |
200~300 |
800~1200 |
1200~1800 |
SW-1700 |
40~56 |
240~330 |
320~440 |
400~560 |
480~670 |
1900~2600 |
2800~4000 |
SW-2200 |
70~100 |
420~600 |
560~800 |
700~1000 |
800~1200 |
3300~4800 |
5000~7200 |
SW-2600 |
110~160 |
660~960 |
880~1200 |
1100~1600 |
1300~1900 |
5200~7600 |
7900~11500 |
SW-3000 |
160~230 |
960~1300 |
1280~1800 |
1600~2300 |
1900~2700 |
7600~11000 |
11500~16500 |
SW-3400 |
220~300 |
1300~1800 |
1700~2400 |
2200~3000 |
2600~3600 |
10000~14400 |
15800~21600 |
SW-4000 |
280~400 |
1600~2400 |
2200~3200 |
2800~4000 |
3300~4800 |
13400~19000 |
20000~28800 |
SW-4400 |
360~510 |
2000~3000 |
2800~4000 |
3600~5100 |
4300~6000 |
17000~24000 |
25900~36700 |
SW-4800 |
440~630 |
2600~3700 |
3500~5000 |
4400~6300 |
5200~7500 |
21000~30000 |
31600~45000 |
SW-5400 |
540~760 |
3000~4500 |
4300~6000 |
5400~7600 |
6400~9000 |
25000~36000 |
38000~54000 |
SW-5800 |
640~900 |
3800~5400 |
5000~7200 |
6400~9000 |
7600~10000 |
30000~43000 |
46000~64000 |
SW-6200 |
740~1000 |
4400~6000 |
5900~8000 |
7400~10000 |
8800~12000 |
35000~48000 |
53000~72000 |
SW-6500 |
860~1200 |
5000~7200 |
6800~9600 |
8600~12000 |
10000~14000 |
41000~57000 |
60000~86000 |
SW-7000 |
1000~1400 |
6000~8400 |
8000~11000 |
10000~14000 |
12000~16800 |
48000~67000 |
72000~100000 |
SW-7400 |
1140~1600 |
6800~9600 |
9000~12800 |
11400~16000 |
13000~19000 |
54000~76000 |
82000~115000 |
explain:
1. The circulation cycle of the swimming pool is determined according to the requirements of Party A and the level (importance) of the pool. It is predicted that for pools with high pedestrian flow in the future, the circulation cycle should be shortened and the lower limit of the water treatment capacity should be taken. Conversely, the cycle can be extended and the upper limit of the water treatment capacity should be taken.
2. The treatment of lake water requires a high water quality and a clear cycle of no more than 24 hours. For visibility requirements of 1.2-1.5m, take 24-48h; for visibility requirements of 0.5-0.8m, take 48-72h. After 72h, the water quality cannot be guaranteed.
Model and Size Table of Hydraulic Automation Water Treatment Machine
model |
Processing water volume m3/h |
Equipment size mm |
Height mm |
Inlet pipe diameter mm |
Diameter of outlet pipe mm |
Diameter of sewage pipe mm |
Net height of computer room mm |
SW-1300 |
18~25 |
1300×1300 |
3400 |
75~100 |
75~100 |
150 |
4500 |
SW-1700 |
40~56 |
1700×1700 |
3400 |
100~150 |
100~150 |
200 |
4500 |
SW-2200 |
70~100 |
2200×2200 |
4000 |
150~200 |
150~200 |
200 |
4500 |
SW-2600 |
110~160 |
2600×2600 |
4400 |
200~250 |
200~250 |
250 |
5000 |
SW-3000 |
160~230 |
3000×3000 |
4400 |
200~250 |
200~250 |
300 |
5000 |
SW-3400 |
220~300 |
3400×3400 |
4400 |
200~300 |
200~300 |
300 |
5000 |
SW-4000 |
280~400 |
4000×4000 |
4400 |
250~350 |
250~350 |
400 |
5000 |
SW-4400 |
360~510 |
4400×4400 |
4400 |
250~400 |
250~400 |
400 |
5000 |
SW-4800 |
440~630 |
4800×4800 |
4700 |
300~500 |
300~500 |
500 |
>5000 |
SW-5400 |
540~760 |
5400×5400 |
4700 |
350~500 |
350~500 |
500 |
>5000 |
SW-5800 |
640~900 |
5800×5800 |
4700 |
400~500 |
400~500 |
600 |
>5000 |
SW-6200 |
740~1000 |
6200×6200 |
4700 |
400~600 |
400~600 |
600 |
>5000 |
SW-6500 |
860~1200 |
6500×6500 |
4700 |
400~600 |
400~600 |
700 |
>5000 |
SW-7000 |
1000~1400 |
7000×7000 |
4700 |
400~600 |
400~600 |
700 |
>5000 |
SW-7400 |
1140~1600 |
7400×7400 |
4700 |
400~700 |
400~700 |
800 |
>5000 |
SW-800(I) |
20~40 |
Φ800 |
1500 |
75~100 |
75~100 |
150 |
1800 |
SW-1000(I) |
20~40 |
1000×1000 |
2200 |
100~150 |
100~150 |
150 |
2500 |
SW-1200(I) |
40~70 |
1200×1200 |
2700 |
150~200 |
150~200 |
200 |
3000 |
SW-1400(I) |
70~100 |
1400×1400 |
2700 |
200~250 |
200~250 |
200 |
3000 |
SW-1600(I) |
100~130 |
1600×1600 |
2700 |
250~300 |
250~300 |
250 |
3000 |
Note:The inlet pipe, return pipe and other pipelines can be connected freely within 360 ° of the plane, while the discharge pipe can only be connected within 360 ° of the bottom of the equipment. It is best to drain vertically downwards from the center of the machine.