Detailed information of 8081 NOx fixed pollution source nitrogen oxide analyzer:
Fixed pollution source nitrogen oxide analyzer
Fixed pollution source nitrogen oxide analyzeroverview
Fixed pollution source nitrogen oxide analyzerThe system can operate 24/724Real time monitoring of the concentration of nitrogen oxides, oxygen content, and other gases in the exhaust emissions of boilers, smoke windows, low nitrogen burners, and other related equipment on an hourly basis, and local data storage for more than one year. Suitable for online monitoring of nitrogen oxide concentration in exhaust gas from gas boilers and low nitrogen burners. Widely used in industries such as petroleum, chemical, printing, rubber products, plastics, pharmaceuticals, electronics, and industrial coatings.
Fixed pollution source nitrogen oxide analyzerTechnical parameters:
Detection parameters:NOX, optional(NO.NO2,O2.SO2Waiting for other gases)
Measurement range:NOX(0100mg/m3)TheO2(0-30%Vol),SO2(0-100mg/m3)Other ranges are optional
Detection principle: Electrochemical principle, depending on the gas composition, concentration, and working conditions at the detection site, optional differential ultraviolet or laser principles are available
Sampling temperature:200Within ℃ (standard), higher temperatures are optional
Sampling humidity:0~90%RHChoose a higher humidity environmentGas pretreatment system
Host working environment:- 40℃~70℃,≤90%RH
Working mode: Online continuous work, pump suction sampling (available in positive pressure, negative pressure, and vacuum environments)
Sampling distance: standard30Meter, the sampling distance of the optional vacuum pump is greater than70rice
Sampling traffic:1rise/Minutes (standard),10rise/Minutes, optional
Working voltage:220VAC,50HZ
Output signal:4~20mA、RS485, Optional:GPRSWireless transmissionWIFITransmission, etc
External dimensions:600mmtall*500mmwide*240mmthick
Protection level:IP65
Display mode:7Inch true color touch screen display
Data storage:100000Article,
Alarm mode: Optional integrated sound and light alarm, built-in or external type
Warm pressure flow: optional, pitot tube/Ceramic filament type