☆Introduction to Constant Temperature and Humidity Test Chamber:
The function of the constant temperature and humidity test chamber is to provide a testing environment with constant high and low temperature humidity, and alternating high and low temperature humidity; Including refrigeration system, heating system, humidification/Dehumidification/water system, air duct system, control system, system safety protection device, etc,The constant temperature and humidity test chamber is a device used to test the performance of materials in various environments and to test the heat resistance, cold resistance, dry resistance, and moisture resistance of various materials. Suitable for quality testing of electronic, electrical, communication, instrument, vehicle, car window, plastic products, metal, food, chemical, building materials, medical, aerospace and other products.
☆ Technical features:
1Adopting original imported Korean three yuanTEMI880 Color TouchThe touch screen display is intuitive and easy to operate,
Permanent historical data storage function.
2. Pre order power on/off function, end planning settings, automatically save data curves during power outages, etc
3. At the end of the experiment, the test sample will automatically return to room temperature to avoid frost and condensation protection mechanism
4. Adopting servo refrigerant flow control technology effectively achieves energy savings of over 30%
5. The experiment is conducted in a loop without affecting the impact time
6. Using pure aluminum finned evaporator, effectively reducing energy storage time and saving energy
7. Inner box material: SUS304 high-quality stainless steel
8. Outer box material: SUS304 mesh stainless steel
☆ Performance of the test chamber
1. Analysis accuracy: Temperature: ± 0.01 ℃; Humidity: ± 0.1% R.H
2. Temperature range: 0 ℃~150 ℃/-20~150 ℃/-40~150 ℃
3. Temperature fluctuation: ± 1.0 ℃
4. Temperature uniformity: ± 2.0 ℃
6. Heating rate: 2 ℃ -4 ℃/min (from room temperature to maximum temperature, non-linear no-load)
7. Cooling rate: 0.7 ℃ -1 ℃/min (from room temperature to the lowest temperature, non-linear no-load)
8. Humidity range: 20%~98%R.H
9. Humidity fluctuation: ±2.0%R.H.
10. Humidity deviation: ±2%
11. Voltage: 380V, Frequency: 50HZ
☆ Heating system:
continuousPID regulation, using AC contactors as heating actuators, safe and reliable, with a separate over temperature protection system.
☆Air duct system:
To ensure a high uniformity index, the test chamber is equipped with an internal circulating air supply system; Inside the air duct interlayer at one end of the studio, heaters are distributed
Refrigeration evaporator, fan blades and other devices; Use a fan to circulate the air in the box, and when the fan rotates at high speed, draw in air from the lower part of the workspace
Inside the duct, after heating and cooling, the air is blown out from above the duct, and after heat exchange with the test sample in the working room, it is then sucked into the duct and repeatedly circulated
Ring to meet the temperature setting requirements.
☆ Control system:
Composition of control system:
Temperature measurement:Pt100 platinum resistor;
Humidity measurement:Pt100 platinum resistance dry wet bulb method;
Control device: touch screen programmable temperature and humidity controllerTEMI880。 It can display set parameters, time, heater, humidifier, etc. It also has automatic test operation and PID control
Parameter self-tuning function.The automatic operation function of the refrigeration machine can be achieved by simply setting the temperature. The control system uses an intelligent control software system with automatic combined heating and heating capabilities
The working conditions of the humidity subsystem ensure high-precision control over the entire temperature and humidity range, achieving the goal of energy conservation and consumption reduction. A sophisticated detection device can automatically display detailed faults,
Alarm, if there is an abnormality in the test chamber, the controller will automatically display the fault status.
Screen display: set temperature and humidity; Actual measured temperature and humidity;
Setting accuracy: 1℃
Operation mode: Constant operation;
Other major low-voltage electrical components use well-known brand products:
☆ Meet the standards:
Performance indicators meetGB5170、 2. Requirements for Verification Methods of Basic Parameters for Environmental Testing - High Temperature, Constant Damp Heat, and Alternating Damp Heat Test Equipment (3-5, 6-95)
Environmental Testing Regulations testB: High temperature test method GB 2423.2-89 (IEC68-2-2)
Environmental Testing Regulations testCa: Constant Damp Heat Test Method GB/T 2423.3-93 (IEC68-2-3)
Environmental Testing Regulations testDa: Alternating heat and humidity test method GB/T423.4-93 (IEC68-2-30)
☆ Specifications and dimensions: (Specifications and models can be customized according to specific needs)
model |
Temperature/humidity range |
Maximum current |
Internal dimensions (W × H × Dmm) |
External dimensions (W × H × Dmm) |
Weight (kg) |
ESV-H-080R |
-20℃~ +150℃ /25 ~ 98%RH |
14.6 |
400×400×500 |
910×870×1760 |
300 |
ESV-H-100R |
-20℃~ +150℃ /25 ~ 98%RH |
16.6 |
500×400×500 |
1010×870×1760 |
315 |
ESV-H-150R |
-20℃~ +150℃ /25 ~ 98%RH |
18.9 |
500×500×600 |
1010×1070×1760 |
335 |
ESV-H-225R |
--20℃~ +150℃ /25 ~ 98%RH |
21.2 |
600×500×750 |
1010×1070×1800 |
360 |
ESV-H-408R |
-20℃~ +150℃ /25 ~ 98%RH |
24.5 |
800×600×850 |
1310×1180×1800 |
385 |
ESV-H-800R |
-20℃~ +150℃ /25 ~ 98%RH |
28.9 |
1000×800×1000 |
1510×1460×1860 |
430 |
ESV-H-1000R |
-20℃~ +150℃ /25 ~ 98%RH |
31.7 |
1000×1000×1000 |
1510×1560×1860 |
460 |