E+H/Endress+Hauser/Endress HauserWhen used in conjunction with Fieldgate FXA320 (which remotely queries measurement values through Internet technology), Liquicap is an ideal choice for inventory management solutions.
The instrument is not affected by the dielectric constant (dc), the conductivity of the liquid is 100 μ S/cm, and it allows measurement of multiple liquids without the need for recalibration.
Process connection: flange and thread
Process pressure:- 1...+100 bar (+1.450 psi)
Measurement range: 0.1... 4.0 m (0.3... 13 ft)
Temperature:- 80...+200°C (-112...+392°F)
International explosion-proof protection certification, overflow protection WHG, SIL, Sanitary certification, classification certification
Fully insulated rod probe, suitable for standard and harsh working conditions (temperature, process, adhesion)
-
Interface measurement
Liquid/liquid interface with lotion layer
-
E+H/Endress+Hauser/Endress Hausercharacteristic
Shield segment length
Factory calibration
short response time -
Power/Communication
12...36 DC HART
PFM -
measurement accuracy
Repeatability is 0.1%
-
Linear error in measurement of conductive liquids
<0.25%
-
ambient temperature
-50...+70°C
-58...+158°F -
process temperature
-80...200°C
-112...392°F -
Process pressure (absolute pressure)/maximum overpressure limit value
Vacuum 100 bar
(Vacuum... 1450 psi) -
Main liquid receiving components
Insulation material: PTFE、PFA
316L -
Process connection
G1/2、G 3/4、G 1、G1 1/2 /NPT 1/2、NPT 3/4、NPT 1'、NPT1 1/2
Minimum flange diameter DN25.../ASME 1 '/ JIS... -
Sanitary process connection
Tri Clamp ISO02852 clamp, no gap
Milk connector
Flat installation -
sensor length
Total length: 6m (20ft)
Shielding section length: maximum 2m (7ft) -
Maximum measurement distance
0.1...4.0 m
(0.3...13 ft) -
communication
4...20mA HART
PFM -
Certificates and certifications
ATEX、FM、CSA、IEC Ex、TIIS、INMETRO、NEPSI
-
safety certification
Overflow protection WHG
SIL -
Design certification
EN 10204-3.1
NACE MR0175 -
Sanitary certification
3A EHEDG
-
Classification certification
GL/ ABS/ DNV
-
option
Separated shell
Sealing ring of airtight probe -
Application Restrictions
The gap with the top of the warehouse is too small
Change, non-conductive medium, conductivity<100 μ S/cm
Pay attention to reducing pressure and temperature