VIP member
Dalong DLAB MicroPette Manual Pipette
Dalong DLAB MicroPette Manual Pipette
Product details
Dalong DLAB MicroPette Manual Pipette
1、 Product Features:
1. Lightweight and designed to conform to ergonomics
2. Digital window, making the set range clear at a glance
3. Wide range of measurement, from 0.1uL to 10mL
4. Using attachment tools allows for convenient and efficient calibration and maintenance
5. Accurate liquid separation, each pipette is calibrated according to EN/ISO8655 standards
6. The lower half can be sterilized under high temperature and high pressure
7. Adopting new materials
2、 Product specifications:
Single channel adjustable pipette | ||||||
range | increment | Measurement volume (μ l) | Maximum allowable system error (Inaccuracy) |
Maximum allowable random error (Inaccurate) |
||
% | μl | % | μl | |||
0.1-2.5μl | 0.05μl | 2.5 | 2.50% | 0.0625 | 2% | 0.05 |
1.25 | 3% | 0.0375 | 3% | 0.0375 | ||
0.25 | 12% | 0.03 | 6% | 0.015 | ||
0.5-10μl | 0.1μl | 10 | 1% | 0.1 | 0.80% | 0.08 |
5 | 1.50% | 0.075 | 1.50% | 0.075 | ||
1 | 2.50% | 0.025 | 1.50% | 0.015 | ||
2-20μl | 0.5μl | 20 | 0.90% | 0.18 | 0.40% | 0.08 |
10 | 1.20% | 0.12 | 1% | 0.1 | ||
2 | 3% | 0.06 | 2% | 0.04 | ||
5-50μl | 0.5μl | 50 | 0.60% | 0.3 | 0.30% | 0.15 |
25 | 0.90% | 0.225 | 0.60% | 0.15 | ||
5 | 2% | 0.1 | 2% | 0.1 | ||
10-100μl | 1μl | 100 | 0.80% | 0.8 | 0.15% | 0.15 |
50 | 1% | 0.5 | 0.40% | 0.2 | ||
10 | 3% | 0.3 | 1.50% | 0.15 | ||
20-200μl | 1μl | 200 | 0.60% | 1.2 | 0.15% | 0.3 |
100 | 0.80% | 0.8 | 0.30% | 0.3 | ||
20 | 3% | 0.6 | 1% | 0.2 | ||
50-200μl | 1μl | 200 | 0.60% | 1.2 | 0.15% | 0.3 |
100 | 0.80% | 0.8 | 0.30% | 0.3 | ||
50 | 1% | 0.5 | 0.40% | 0.2 | ||
100-1000μl | 5μl | 1000 | 0.60% | 6 | 0.20% | 2 |
500 | 0.70% | 3.5 | 0.25% | 1.25 | ||
100 | 2% | 2 | 0.70% | 0.7 | ||
200-1000μl | 5μl | 1000 | 0.60% | 6 | 0.20% | 2 |
500 | 0.70% | 3.5 | 0.25% | 1.25 | ||
200 | 0.90% | 1.8 | 0.30% | 0.6 | ||
1000-5000μl | 50μl | 5000 | 0.50% | 25 | 0.15% | 7.5 |
2500 | 0.60% | 15 | 0.30% | 7.5 | ||
1000 | 0.70% | 7 | 0.30% | 3 |
Fixed pipette | |||||||
range | increment | Measurement volume (μ l) | Maximum allowable system error (Inaccuracy) |
Maximum allowable random error (Inaccurate) |
|||
% | μl | % | μl | ||||
5μl | - | 5μl | 1.3% | 0.065 | 1.2% | 0.06 | |
10μl | - | 10μl | 0.8% | 0.08 | 0.8% | 0.08 | |
20μl | - | 20μl | 0.6% | 0.12 | 0.5% | 0.1 | |
25μl | - | 25μl | 0.5% | 0.125 | 0.3% | 0.075 | |
50μl | - | 50μl | 0.5% | 0.25 | 0.3% | 0.15 | |
100μl | - | 100μl | 0.5% | 0.5 | 0.3% | 0.3 | |
200μl | - | 200μl | 0.4% | 0.8 | 0.2% | 0.4 | |
250μl | -- | 250μl | 0.4% | 1.0 | 0.2% | 0.5 | |
500μl | - | 500μl | 0.3% | 1.5 | 0.2% | 1.0 | |
1000μl | - | 1000μl | 0.3% | 3.0 | 0.2% | 2.0 | |
2000μl | - | 2000μl | 0.3% | 6.0 | 0.15% | 3.0 | |
5000μl | - | 5000μl | 0.3% | 15 | 0.15% | 7.5 |
3、 Product Code:
Product Code | range |
7030201001 | 0.1-2.5μl |
7030201004 | 0.5-10μl |
7030201005 | 2-20μl |
7030201006 | 5-50μl |
7030201008 | 10-100μl |
7030201009 | 20-200μl |
7030201011 | 50-200μl |
7030201014 | 100-1000μl |
7030201016 | 200-1000μl |
7030201017 | 1000-5000μl |
7030201033 | 2-10ml |