Shanghai Fangrui Instrument Co., Ltd
Home>Products>Contact angle meter
Contact angle meter
not have
Product details

JCY series contact angle meter manufacturer (droplet angle meter) is a standard type instrument used to measure solid contact angle (droplet angle), surface energy, and liquid surface tension. Adopting advanced optical video measurement technology, the images captured by high-precision industrial cameras are sent to a computer for data processing, with complete functions and very convenient operation. Compliant with ASTM D 724, ASTM D 5946, ISO15969 and other standards. Widely used for quality testing in industrial and mining enterprise laboratories, as well as scientific research and experiments in colleges and universities.

Main technical features:

1. Adopting advanced specialized digital cameras with high resolution, precision, and clarity; Maximum resolution: 1280 × 1024, frame rate: 15 or 45/second;

2. High brightness LED background light source system, with uniform illumination and continuously adjustable brightness;

3. The direction of the injection system can be adjusted (up and down, left and right, tilt), which can easily obtain the required droplets. 4. Using a micro injection device, the size of the droplets can be accurately controlled, and manual control can reach 0.1 μ l (using a high-precision injection pump can reach 0.005 μ l);

4. Adopting a micro injection device, the injection volume can be accurately controlled, with manual control reaching 0.1 μ l and high-precision injection pump reaching 0.05 μ l.

5. Three dimensional sample stage;

6. CONTA 3.0 contact angle analysis software, based on operating platforms such as WINDOWS XP and WINDOWS 7, has a user-friendly interface, easy operation, powerful functions, and accurate measurement values

① The contact angle method is used to measure the surface tension of solids. The automatic calculation function includes: θ/2 method, tangent method to calculate contact angle, which can be automatically calculated or manually (corrected) calculated; Comparison of left and right contact angles; Multi point contact angle comparison;

② Calculation of surface free energy, droplet volume, and solid adhesion force using one liquid method and two liquid method;

③ The dynamic contact angle analysis system can continuously take photos, automatically record the changes in contact angle at different times, and analyze the forward angle, backward angle, tilt angle, and rolling angle;

④ The suspended droplet method is used to measure the surface tension of liquids, and the latest calculation functions include: S-H table method, shape factor method;

⑤ The horizontal calibration method combining software and hardware can accurately and conveniently find the horizontal baseline;

⑥ The test results are saved in the database in the form of a test report, which can be compressed and backed up, and can automatically generate Excel files;

⑦ Test environment setup, liquid dictionary maintenance

⑧ Software brightness correction function

Note: The above functions may vary depending on different models, and specific parameters can be described below:


Main technical parameters:

model

JCY-1

JCY-2

JCY-3

JCY-4

Camera system

Professional CCD digital camera+high-performance microscope lens

Highest resolution

1280×1024

Frame rate

15 or 45/second

horizontal resolution

850 lines

Capture Mode

Single sheet, continuous

Single sheet, continuous

light source

Continuous adjustable brightness LED cold light source, uniform emission, clearer image contours, and higher resolution


Contact angle analysis method

θ/2 method, tangent method, can be automatically calculated or manually (corrected) calculated

Contact angle measurement range

0 ~ 180°

Contact angle test resolution

0.01°

Accuracy of contact angle testing

0.1°

Standard angle calibration

15 °,45°,90°,135°

Solid surface energy, etc


Calculation of surface free energy, droplet volume, and solid adhesion force using one liquid method and two liquid method

Surface tension testing method



S-H table method, shape factor method

Surface tension testing range


0 ~ 400mN/m

Resolution of surface tension testing


0.01 mN/m

Sample table displacement

Front and back: 60mm; Left and right 35mm; Up and down 35mm
The sample stage can be horizontally adjusted

Sample table size

100 ×100mm

Maximum sample size

200 × 200mm or φ 200mm

Maximum thickness of sample

≤30mm

Tilting platform


Measure the forward/backward angle and sliding angle


Measure the forward/backward angle and sliding angle

Injection method

Micro injector

Constant temperature platform

option

Overall dimensions of the host

525 × 160 × 450 (length × width × height)

Net weight of the host

12kg

Power Supply and Power

220V, 0.2KW


Contact angle measurement

Measurement of liquid surface tension

JCY series water contact angle measuring instrument standard configuration:

Serial Number

name

quantity

1

Host (including standard industrial camera device, 3D sample stage)

1

2

Manual differential head injection device

1

3

Micro injector

2

4

data line

1

5

data line

1

6

certificate of conformity

1

7

warranty card

1

8

operation instructions

1


Application field: Wetting or adhesion between ink and paper, plastic, metal in the printing industry

Development of high-performance synthetic materials

Determination of surface cleanliness of semiconductor materials, silicon chips, glass, etc

Cosmetics and pharmaceutical industry, such as research on surface properties of cream or powder

Textile materials

Surface treatment with surface active substances

Adsorption behavior of water absorbing substances