Shanghai Hegong Scientific Instrument Co., Ltd
Home>Products>Battery raw material Karl Fischer moisture detector
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    13816576869
  • Address
    B4-1, Fuhua High tech Park, No. 33 Fuhua Road, Jiading District, Shanghai
Contact Now
Battery raw material Karl Fischer moisture detector
The AKF series Karl Fischer moisture analyzer is a fully automatic volumetric Karl Fischer moisture analyzer with independent intellectual property ri
Product details

Lithium batteries are closely related to our lives and play an indispensable role. For example, our phones, laptops, household appliances, etc. that we never leave our hands on every day. The demand for lithium-ion batteries has also significantly increased in transportation vehicles such as airplanes, hybrid vehicles, and electric vehicles. In the manufacturing process of lithium-ion batteries, there are many things that must be strictly controlled, including dust, metal particles, and moisture.

2、 The impact of moisture on lithium batteries and market status

2.1 What adverse effects does moisture have on lithium-ion batteries?
The main manifestations are small battery capacity, shorter discharge time, increased internal resistance, decreased cycling capacity, battery expansion, etc. Therefore, in the production process of lithium-ion batteries, it is necessary to strictly control the humidity of the environment and the moisture content of the positive and negative electrode materials, separators, and electrolytes.

What is the current status of moisture control methods for lithium-ion batteries?
At present, the most commonly used technical methods for determining moisture content in the market are the heating weight loss method and the Karl Fischer method. Due to the extremely low moisture content of the samples measured in the lithium battery industry, the accuracy of the heating weight loss method moisture analyzer cannot be achieved, and this method is directly excluded.

IIIAnalysis and Methods

3.1 Instruments
AKF-BT2015C Lithium Battery Karl Fischer Moisture Analyzer

3.2 Technical Parameters and Characteristics

technical parameter
measuring range 3ug-99mg (H2O mass)
Measurement method Karl Fischer Coulombic titration+Karl Fischer headspace sampler
Sample heating method Bottle heating gas injection
Needle specifications 0.3mm
Measurement resolution 0.1ug (H2O mass)
Host display screen size 7 "color touch screen
Parameter display Moisture percentage content, moisture percentage ppm, and the volume of consumed cartridge reagents containing water in the sample;
Determination of repeatability 99.7% (1000 μ g pure water)
Sample measurement time On average, 50 seconds to a few minutes
Flow range 0-100ml/min(0.1Mpa)
data storage The instrument automatically stores 200 pieces of data
Printing function Printing function: dedicated external printer (optional)
language Chinese and English optional
Calibration function have
Automatic function Automatic balancing, automatic background subtraction, automatic calculation and saving of results



characteristic:
1. Karl Fischer headspace sample bottle heating technology effectively avoids contamination of the heating furnace and reaction cup;
2. The sample bottle connector created by Hegong allows the carrier gas to enter the interior of the sample bottle without piercing the sample bottle spacer, with good sealing and easy disassembly while reducing the use of spacer consumables;
3. With precise flow control design, the consumption of carrier gas is only one tenth of that of similar imported tubular heating furnaces;
4. High power heat dissipation groove design, quickly cooling sample bottles and improving work efficiency;
5.7 "high-resolution color touch screen interface, multi parameter display, intuitive and concise; one click measurement, extremely easy to operate;
6. The anti condensation insulation pipeline is designed without dead volume to ensure that there is no residual moisture in the pipe wall system after evaporation;
7. The heating temperature can reach up to 300 ° C, and the gas flow rate can be freely adjusted from 0-100ml to meet the moisture determination needs of most solid raw materials;
8. Fully automatic constant current polarization detection, no need for manual endpoint setting, high detection accuracy, moisture measurement resolution up to 0.1ug;
9. One click start, simple operation, stable and reliable, low failure, long service life;



3.3 Analysis principle
The sample is loaded into a sealed injection vial specifically designed for a Karl Fischer oven. After being sealed with a headspace bottle connector, it enters the heating tank. The moisture (which may also contain other volatile solvents) in the sample is completely released in the form of vapor. It is then transferred from the headspace bottle to a KF titration cup through a dry carrier gas (such as dry air or nitrogen) via a heating companion tube. The Karl Fischer moisture analyzer is used for detection and displays the measurement data.


3.4 Testing Methods

1. Inject the electrolyte into the electrolytic cell and the cathode chamber of the electrolysis electrode, raise the liquid level to the lower scale line, add a small amount of water, and then electrolyze to equilibrium.
2. Connect the gas source to the Kjeldahl heating furnace, place the dry sample bottle into the heating tank, set the temperature to 250 ℃, adjust the flow rate to 50mL/min, blow the sample bottle and pipeline for possible moisture, and wait for further equilibration.
3. Move the sample bottle to the cooling tank and remove it after cooling. Use an electronic balance to weigh about 0.5-3g of the sample and place it in the sample bottle. Then click on the moisture meter to start measuring, and at the same time, place the sample bottle into the heating tank.
4. Enter the weight of the sample to be weighed and wait for the final measurement result to be displayed after the measurement is completed.



4Data and Conclusion

Experimental reagent: Coulombic coulometric single Karl Fischer reagent, equivalent to 1.5g/100ml, kfr-c02
Current drift value: 0.3ug/min
Environmental temperature: 18 ℃ Environmental humidity: 51%



HOGON Karl Fischer Moisture Analyzer Sample Measurement Record

Determination order Injection volume Electrolysis value Measurement results Analysis duration
Sample Name Negative electrode membrane
Sample 1-1 0.535g 1718.4ug 3212ppm 12min
Sample 1-2 0.498g 1627.5ug 3268ppm 12min
Sample 2-1 1.054g 609.2ug 578ppm 9min
Sample 2-2 1.218g 665.0ug 546ppm 9min
Sample Name Graphite powder
1 3.014g 415.9ug 138ppm 6min
2 3.140g 445.8ug 142ppm 6min
Sample Name Lithium iron phosphate
1 1.603g 660.4ug 412ppm 10min
2 1.428g 615.5ug 431ppm 10min



5、 Conclusion statement:
Through this experimental method, the moisture content of lithium-ion battery raw materials can be accurately measured, and the accuracy and repeatability of the detection results reach the level of similar imported products. The AKF Coulombic Karl Fischer Moisture Analyzer, combined with the KH-1 Karl Fischer Furnace Headspace Sample Injector, can automatically deduct drift, is easy to operate, and can accurately and reliably measure the moisture content of lithium batteries and raw materials.



This method is also applicable to graphene, lithium iron phosphate, lithium battery raw materials, and electrolytesMoisture detection for iron phosphate, lithium cobalt oxide, lithium manganese oxide, lithium nickel oxide, ternary materials, negative electrode membranes, graphite powder, and other insoluble solid materials.



Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!